Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM95
Rated Operational Current (Ie) 95 A at AC-3, 400V
Thermal Current (Ith) 95 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts Typically 1 NO (Normally Open) - Fixed (configurable with additional blocks)
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage Available in multiple standard AC voltages (e.g., 24V, 110V, 230V, 400V AC). The specific voltage must be specified when ordering.
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 45 kW / 60 HP
Mechanical Life ~ 10 million operations
Electrical Life (AC-3) ~ 1 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM170C XTCE170GC
Rated Operational Current (Ie) 170 A at AC-3, 400V
Thermal Current (Ith) 170 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts Typically 1 NO (Normally Open) - Fixed (configurable with additional blocks)
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage DC operating coil (Specific voltage defined by the XTCE170GC suffix).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 75 kW / 100 HP
Mechanical Life ~ 5-10 million operations
Electrical Life (AC-3) ~ 0.5-1 million operations
Mounting Screw mounting (due to size and weight)
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM17-10
Rated Operational Current (Ie) 17 A at AC-3, 400V
Thermal Current (Ith) 17 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts 1 NO (Normally Open) + 1 NC (Normally Closed) - Convertible
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage Available in multiple standard AC voltages (e.g., 24V, 110V, 230V, 400V AC). The specific voltage must be specified when ordering.
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 7.5 kW / 10 HP
Mechanical Life ~ 15 million operations
Electrical Life (AC-3) ~ 1.5 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Cage Clamp / Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM9-10C
Rated Operational Current (Ie) 9 A at AC-3, 400V
Thermal Current (Ith) 9 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts 1 NO (Normally Open) + 1 NC (Normally Closed) - Convertible
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage DC operating coil (Specific voltage must be specified when ordering, e.g., 24V DC, 110V DC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 4 kW / 5.5 HP
Mechanical Life ~ 15 million operations
Electrical Life (AC-3) ~ 1.5 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Cage Clamp / Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM25-10C
Rated Operational Current (Ie) 25 A at AC-3, 400V
Thermal Current (Ith) 25 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts 1 NO (Normally Open) + 1 NC (Normally Closed) - Convertible
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage DC operating coil (Specific voltage must be specified when ordering, e.g., 24V DC, 110V DC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 11 kW / 15 HP
Mechanical Life ~ 15 million operations
Electrical Life (AC-3) ~ 1.5 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Cage Clamp / Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, M25 Series
Model Number M25-01C
Sensor Type Inductive Proximity Sensor
Housing Material Nickel-plated brass or Stainless Steel
Thread Size M25 x 1.5
Connection Type Built-in connector (e.g., M12 connector)
Sensing Distance 8 mm (Standard for M25 inductive sensors)
Output Type DC 3-wire
Output Logic PNP (Sourcing output) - "C" often indicates PNP, NO
Output Function Normally Open (NO)
Supply Voltage 10-30V DC
Rated Operating Current ≤ 200 mA
Switching Frequency ≤ 500 Hz
Protection Degree IP67
Standards Compliance IEC 60947-5-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM150C
Rated Operational Current (Ie) 150 A at AC-3, 400V
Thermal Current (Ith) 150 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts Typically 1 NO (Normally Open) - Fixed (configurable with additional blocks)
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage DC operating coil (Specific voltage must be specified when ordering, e.g., 24V DC, 110V DC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 75 kW / 100 HP
Mechanical Life ~ 5-10 million operations
Electrical Life (AC-3) ~ 0.5-1 million operations
Mounting Screw mounting (due to size and weight)
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILEM Series
Model Number DILEM-10
Rated Operational Current (Ie) Specific current rating corresponding to "10" code (typically in the range of 9-12A)
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts Convertible auxiliary contacts (configuration varies by specific "10" variant)
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage Available in multiple standard AC voltages (e.g., 24V, 110V, 230V AC)
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Mounting Standard 35mm DIN Rail (EN 60715)
Standards Compliance IEC/EN 60947-4-1
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, M115 Series
Model Number M115-150
Sensor Type Inductive Proximity Sensor
Housing Shape Rectangular
Housing Material Typically Metal (e.g., nickel-plated brass or stainless steel) with plastic sensing face
Sensing Distance 150 mm (The "150" in model number indicates 150mm sensing range)
Connection Type Pre-wired cable or connector (specific type to be confirmed)
Output Type DC 3-wire (Typically)
Output Logic PNP or NPN (Specific type to be confirmed via datasheet)
Output Function Normally Open (NO) or Normally Closed (NC)
Supply Voltage 10-30V DC
Rated Operating Current ≤ 200 mA
Switching Frequency ≤ 100 Hz (Typical for long-range sensors)
Hysteresis ≤ 10% of sensing distance
Protection Degree IP67
Standards Compliance IEC 60947-5-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, M115 Series
Sensor Type Inductive Proximity Sensor
Housing Shape Rectangular
Housing Material Typically Metal (e.g., nickel-plated brass or stainless steel) with plastic sensing face
Sensing Distance Multiple ranges available (e.g., 40mm, 80mm, 150mm - specified by suffix)
Connection Type Pre-wired cable or Connector versions available
Output Type DC 3-wire
Output Logic PNP (Sourcing) or NPN (Sinking) options
Output Function Normally Open (NO) or Normally Closed (NC)
Supply Voltage 10-30V DC
Rated Operating Current ≤ 200 mA
Switching Frequency Varies by model (e.g., 25Hz to 100Hz typically)
Protection Degree IP67
Standards Compliance IEC 60947-5-2