Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, MFD Series
Model Number MFD-80-B
Power Supply Voltage 24-240V AC/DC (Wide range, auto-sensing)
Output Relay DPDT (2 CO) - 2 Changeover contacts
Contact Rating: Typically 8A @ 250V AC
Timing Ranges Multiple ranges selectable (e.g., from 0.1 seconds up to 100 hours)
Functions Multiple timing functions selectable (e.g., On-delay, Off-delay, Interval, Flasher, etc.)
Accuracy ±0.5% of set time ± 20 ms
Mounting DIN Rail (35mm)
Display / Indication Digital Display and LED Status Indicators
Standards Compliance IEC/EN 61812-1, UL 508, CSA C22.2 No. 14
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, EASY600 Series
Model Number EASY620-DC-TE
Power Supply 24V DC
Digital Inputs 12 (24V DC, sink/source)
Digital Outputs 8 (Relay outputs)
Integrated Expansion Yes (TE - Totally Enclosed design with additional I/O)
Program Memory ~1 KB (typical for EASY600 series)
Mounting DIN Rail (35mm)
Programming EASY-SOFT software or front-panel display
Communication Optional communication interfaces
Standards Compliance IEC/EN 61131-2, UL 508, CSA C22.2 No. 14
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, MFD Series
Model Number MFD-RA17
Power Supply Voltage 24-240V AC/DC (Wide range, auto-sensing - typical for MFD series)
Output Relay DPDT (2 CO) - 2 Changeover contacts
Contact Rating: Typically 8A @ 250V AC
Timing Ranges Multiple ranges selectable (e.g., from 0.1 seconds up to 100 hours)
Functions Specific timing functions defined by the RA17 code (e.g., a particular combination of On-delay, Off-delay, Interval, etc.)
Accuracy ±0.5% of set time ± 20 ms
Mounting DIN Rail (35mm)
Display / Indication Digital Display and LED Status Indicators
Standards Compliance IEC/EN 61812-1, UL 508, CSA C22.2 No. 14
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-B32/1
Fuse Class & Rating Class B
Rated Current: 32 A
Rated Voltage: 600V AC / 300V DC
Number of Poles / Quantity 1 piece (Single fuse)
Type Time-Delay (Dual-Element)
Rated Voltage 600V AC / 300V DC
Interrupting Rating 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-12 (Class B), CSA C22.2 No. 248.12
Electrical Characteristics Current-Limiting: Yes
Time-Delay: Can withstand 500% of rated current for several seconds.
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting / Fuse Holder Requires a compatible Class B fuse holder or fuse block
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, MFD Series
Model Number MFD-R16
Power Supply Voltage 24-240V AC/DC (Wide range, auto-sensing - typical for MFD series)
Output Relay DPDT (2 CO) - 2 Changeover contacts
Contact Rating: Typically 8A @ 250V AC
Timing Ranges Multiple ranges selectable (e.g., from 0.1 seconds up to 100 hours)
Functions Specific timing functions defined by the R16 code (e.g., a particular combination of On-delay, Off-delay, Interval, etc.)
Accuracy ±0.5% of set time ± 20 ms
Mounting DIN Rail (35mm)
Display / Indication Digital Display and LED Status Indicators
Standards Compliance IEC/EN 61812-1, UL 508, CSA C22.2 No. 14
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILER Series
Model Number DILER-31
Rated Operational Current (Ie) 6 A (for AC-15 category, 250V AC)
Poles 4-Pole (Typically 4 Changeover (CO) contacts)
Contact Configuration 4 CO (4 Changeover contacts - 4 NO + 4 NC)
Rated Operational Voltage (Ue) Up to 250V AC / 300V DC
Control Coil Voltage Available in multiple standard AC and DC voltages (e.g., 24V, 110V, 230V AC/DC). The specific voltage is not defined by "31" and must be specified when ordering.
Utilization Categories AC-15: Control of electromagnetic loads (≤ 720 VA)
DC-13: Control of electromagnetic loads
Mechanical Life ~ 10 - 30 million operations
Electrical Life Varies by utilization category (e.g., ~ 1-3 million operations at rated AC-15 load)
Mounting Standard 35mm DIN Rail (EN 60715)
Standards Compliance IEC/EN 60947-5-1
Terminal Type Cage Clamp or Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILER Series
Model Number DILER-22-G
Rated Operational Current (Ie) 6 A (for AC-15 category, 250V AC)
Poles 2-Pole
Contact Configuration 2 CO (2 Changeover contacts - 2 NO + 2 NC)
Rated Operational Voltage (Ue) Up to 250V AC / 300V DC
Control Coil Voltage Available in multiple standard AC and DC voltages (e.g., 24V, 110V, 230V AC/DC). The specific voltage must be specified when ordering.
Utilization Categories AC-15: Control of electromagnetic loads (≤ 720 VA)
DC-13: Control of electromagnetic loads
Mechanical Life ~ 10 - 30 million operations
Electrical Life Varies by utilization category (e.g., ~ 1-3 million operations at rated AC-15 load)
Mounting Standard 35mm DIN Rail (EN 60715)
Standards Compliance IEC/EN 60947-5-1
Terminal Type Cage Clamp or Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM80-11N
Rated Operational Current (Ie) 80 A at AC-3, 400V
Thermal Current (Ith) 80 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts 1 NO (Normally Open) + 1 NC (Normally Closed) - Convertible
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage AC operating coil (Specific voltage must be specified when ordering, e.g., 230V AC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 37 kW / 50 HP
Mechanical Life ~ 10 million operations
Electrical Life (AC-3) ~ 1 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM95C XTCE095FC
Rated Operational Current (Ie) 95 A at AC-3, 400V
Thermal Current (Ith) 95 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts Typically 1 NO (Normally Open) - Fixed (configurable with additional blocks)
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage DC operating coil (Specific voltage defined by the XTCE095FC suffix, e.g., 24V DC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 45 kW / 60 HP
Mechanical Life ~ 10 million operations
Electrical Life (AC-3) ~ 1 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM80C
Rated Operational Current (Ie) 80 A at AC-3, 400V
Thermal Current (Ith) 80 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts Typically 1 NO (Normally Open) - Fixed (configurable with additional blocks)
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage DC operating coil (Specific voltage must be specified when ordering, e.g., 24V DC, 110V DC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 37 kW / 50 HP
Mechanical Life ~ 10 million operations
Electrical Life (AC-3) ~ 1 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Screw Clamp