Products
Products
home
EATON
P3-63/14/SVB/HI11
Category Parameter Specification / Typical Value Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing) Input Frequency 50 / 60 Hz Input Current Max. ~1.5 A @ 100 VAC Inrush Current Limiting Yes, NTC thermistor Output Characteristics Output Voltage Approx. 14 V DC (Critical: Must verify actual value with datasheet) Rated Output Current ~4.5 A (Calculated from 63W / 14V) Rated Output Power 63 W Efficiency Typically > 89% (Characteristic of high-end P3 series) Ripple and Noise Typically < 100 mVpp Line Regulation < 0.5% Load Regulation < 0.5% Monitoring & Signaling (HI11 Option) Signal Contact DC-OK Relay (Floating changeover contact) Contact Rating Typically 24V DC / 2A (or 230V AC / 2A) Function Changes state when output voltage is within normal range; indicates power failure. Protection & Safety Overload Protection Electronic, auto-recovery Overvoltage Protection Electronic, auto-recovery Short-Circuit Protection Yes, electronic with auto-recovery Standards CE, cULus Listed, GL (Marine) Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C) Cooling Method Fanless (Convection) Mounting Standard 35 mm DIN Rail Protection Rating IP20 Connections Screw Terminals

More details >> Request a Quote >>
EATON
P3-63/EA - 63W
Category Parameter Specification / Typical Value Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing) Input Frequency 50 / 60 Hz Inrush Current Limiting Yes Output Characteristics Output Voltage Likely 24 V DC (Must be verified with datasheet - other voltages like 12V or 48V are possible) Rated Output Current ~2.6 A (if output is 24V) Rated Output Power 63 W Efficiency Typically > 89% Ripple and Noise < 100 mVpp Redundancy Function Redundancy Capability Yes, designed for parallel operation Key Component Integrated OR-ing diode to prevent reverse current Load Sharing Typically not active current sharing; relies on diode decoupling Protection & Safety Overload Protection Electronic, auto-recovery Overvoltage Protection Electronic, auto-recovery Short-Circuit Protection Yes Standards CE, cULus Listed Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C) Cooling Method Fanless (Convection) Mounting Standard 35 mm DIN Rail Connections Screw Terminals

More details >> Request a Quote >>
EATON
EPF31P-M304V1O2PS
Category Parameter Specification / Typical Value Electrical Ratings Rated Voltage 300 VAC (3~ + PE) Rated Current ~16 A (Critical: Must verify exact value with datasheet - common values are 16A, 20A, 30A for this form factor) Frequency 50/60 Hz Test Standards Safety Standards UL 60939, IEC 60939, EN 60939 EMC Standards Designed to meet CISPR 11/32, EN 55011/55032 Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz) > 40 dB (Typical at 100 kHz) Leakage Current Line to Ground Typically < 5 mA (at 250VAC, 50Hz) General Data Number of Phases 3-Phase + Protective Earth (PE) Connection Type Screw Terminals (for both line and load sides) Mounting Through-hole or bracket mounting (panel mount) Operating Temperature -25 °C to +100 °C Housing Material Metal case (typically aluminum) for shielding

More details >> Request a Quote >>
EATON
EF2TO006S6
Category Parameter Specification / Typical Value Motor Protection Setting Current Range (Iᵣ) 0.06 - 0.6 A (This is the core protective range) Tripping Class 10 (Standard) / 20 (e.g., for high-inertia loads) - Selectable Protection Functions • Overload • Phase Loss / Unbalance • Jam Protection (with adjustable trip time) • Earth Fault Protection (optional, depends on version) Electrical Characteristics Rated Operational Voltage (Uᵢ) Up to 690 V AC Supply Voltage (for electronics) Typically 24-240 V AC/DC (Auxiliary voltage for the relay's own circuitry) Contacts Output Auxiliary Contacts • 1 NO (95-96) - Fault Signal • 1 NC (97-98) - Fault Signal Rated Current of Aux. Contacts Typically 6 A General Data Mounting Snap-on to compatible Eaton contactors (e.g., DILM series) Standards IEC/EN 60947-4-1, UL 508 Status Indication LED indicators for "Ready", "Alarm/Trip" Ambient Temperature -20 °C to +60 °C

More details >> Request a Quote >>
EATON
TO-2-1/E
Category Parameter Specification / Typical Value Application & Configuration Protected Circuit Signal circuits (e.g., 4-20 mA, digital I/O) Circuit Configuration 2-pole (Line-to-Line and Line-to-Ground protection) Connection In-series with the signal line Electrical Characteristics Nominal Voltage 8 - 24 V DC (Typical for signal applications) Max. Continuous Operating Voltage (Uc) ~30 V DC (Please verify in datasheet) Nominal Current (In) Up to 250 mA (Suitable for most signal loops) Voltage Drop < 1.5 V (Low, to minimize impact on the signal) Surge Protection Performance Standards Complies with IEC 61643-21 Nominal Discharge Current (In) 5 kA (8/20 μs waveform) Max. Discharge Current (Imax) 10 kA (8/20 μs waveform) Protection Level (Up) < 40 V (at In, typical for this class) General Data Mounting 35 mm DIN Rail Connection Type Screw terminals Housing Material Plastic (PA 6.6) Operating Temperature -40 °C to +80 °C Status Indication None (This is a basic model without visual fault indicator)

More details >> Request a Quote >>
EATON
TO-2-1/EA/SVB
Category Parameter Specification / Typical Value Application & Configuration Protected Circuit Signal circuits (e.g., 4-20 mA, digital I/O) Circuit Configuration 2-pole (Line-to-Line and Line-to-Ground protection) Connection In-series with the signal line Electrical Characteristics Nominal Voltage 8 - 24 V DC Max. Continuous Operating Voltage (Uc) ~30 V DC Nominal Current (In) Up to 250 mA Voltage Drop < 1.5 V Surge Protection Performance Standards Complies with IEC 61643-21 Nominal Discharge Current (In) 5 kA (8/20 μs) Max. Discharge Current (Imax) 10 kA (8/20 μs) Protection Level (Up) < 40 V (at In) Monitoring & Signaling (EA Option) Alarm Contact Floating changeover contact (SPDT) Contact Rating Typically 24V DC / 2A (or 230V AC / 2A) Function Changes state upon internal failure of the SPD, signaling the need for replacement. General Data Mounting 35 mm DIN Rail Connection Type Screw terminals (for both signal and alarm contacts) Housing Material Plastic (PA 6.6) Operating Temperature -40 °C to +80 °C Status Indication None (Visual status may not be present; reliance on alarm contact)

More details >> Request a Quote >>
EATON
P3-63/EA/SVB-SW
Category Parameter Specification / Typical Value Input Characteristics Input Voltage 100 - 240 VAC (Wide Range) Input Frequency 50 / 60 Hz Inrush Current Limiting Yes Output Characteristics Output Voltage Likely 24 V DC (Must be verified with datasheet) Rated Output Current ~2.6 A (if output is 24V) Rated Output Power 63 W Efficiency Typically > 89% Ripple and Noise < 100 mVpp Redundancy Function (EA) Redundancy Capability Yes, designed for parallel operation Key Component Integrated OR-ing diode Integrated Control Function (-SW) PLC Runtime Pre-installed license for Eaton SPC/SPS Programming Software Eaton XVS software package Memory for User Program Typically several MB (for logic, data logs, recipes) Protection & Safety Overload Protection Electronic, auto-recovery Overvoltage Protection Electronic, auto-recovery Standards CE, cULus Listed Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating) Cooling Method Fanless (Convection) Mounting Standard 35 mm DIN Rail Connections Screw Terminals

More details >> Request a Quote >>
EATON
P3-63/EA/SVB
Category Parameter Specification / Typical Value Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing) Input Frequency 50 / 60 Hz Inrush Current Limiting Yes Output Characteristics Output Voltage Likely 24 V DC (Must be verified with datasheet) Rated Output Current ~2.6 A (if output is 24V) Rated Output Power 63 W Efficiency Typically > 89% Ripple and Noise < 100 mVpp Line Regulation < 0.5% Load Regulation < 0.5% Redundancy Function (EA) Redundancy Capability Yes, designed for parallel operation Key Component Integrated OR-ing diode to prevent reverse current Protection & Safety Overload Protection Electronic, auto-recovery Overvoltage Protection Electronic, auto-recovery Short-Circuit Protection Yes Standards CE, cULus Listed Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C) Cooling Method Fanless (Convection) Mounting Standard 35 mm DIN Rail Protection Rating IP20 Connections Screw Terminals

More details >> Request a Quote >>
EATON
P1-25/I2/SVB
Category Parameter Specification / Typical Value Input Characteristics Input Voltage 100 - 240 VAC (Wide Range) Input Frequency 50 / 60 Hz Output Characteristics Output Voltage 24 V DC Rated Output Current ~1.0 A (at 24V) Rated Output Power 25 W Efficiency Typically > 80% Communication Interface (I2) Protocol IO-Link Functionality • Remote monitoring of output parameters (U, I, P, T) • Diagnostic data (e.g., overload events, short-circuit events) • Parameter setting Protection & Safety Overload Protection Electronic, auto-recovery Overvoltage Protection Electronic, auto-recovery Short-Circuit Protection Yes Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating) Cooling Method Fanless (Convection) Mounting Standard 35 mm DIN Rail Connections Screw Terminals (for Power) & IO-Link Port (for Communication)

More details >> Request a Quote >>
EATON
M22-K10
Category Parameter Specification / Typical Value Electrical Characteristics Contact Configuration 1 NO (One Normally Open Contact) Rated Operational Voltage (Ue) Up to 500V AC / 600V DC Rated Impulse Withstand Voltage (Uimp) 6 kV Rated Thermal Current (Ith) 10 A Utilization Category (AC) AC-15: Control of electromagnetic loads (>72 VA) Utilization Category (DC) DC-13: Control of DC electromagnets Mechanical & Switching Electrical Life > 1,000,000 cycles (at rated operational current) Mechanical Life > 5,000,000 cycles Degree of Protection (with actuator) IP65 (Front panel) General Data Mounting Hole Diameter 22.5 mm (ISO Standard) Connection Type Screw Clamp Terminals Actuator Dependency Requires a separate M22 series pushbutton actuator (e.g., a colored button cap) Material Thermoplastic housing Standards IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14

More details >> Request a Quote >>
1 2
··· ···