Key Parameters
Category Description / Value
Product Line Eaton XT Timer Relays
Type Multi-function Timer Relay
Supply Voltage Typically 24-240V AC/DC (verify from datasheet)
Time Range Adjustable (seconds/minutes/hours)
Output Configuration Relay contact (SPDT or similar)
Mounting DIN rail (35mm)
Display May include LED indicators
Connection Screw terminals
Standards IEC/EN 60947-5-1
Key Parameters
Category Description / Value
Product Line Eaton Crouse-Hinds S811 Series
Type Explosion-Proof LED Floodlight
Light Source 50W LED
Input Voltage 120V AC (as indicated by N3 code)
Housing Color Silver/Grey
Hazardous Location Class I Division 2, Class II Division 2, Class III
Enclosure Rating NEMA 4X
Protection Level IP66/IP67
Body Material Copper-free aluminum
Key Parameters
Category Description / Value
Product Line Eaton M22 Inductive Sensors
Sensor Type Inductive Proximity Sensor
Housing Diameter 22mm
Sensing Distance Typically 5-8mm (verify from datasheet)
Output Type PNP (as indicated by PV code)
Connection M12 connector (as indicated by KC11)
Supply Voltage 10-30V DC
Housing Material Nickel-plated brass
Protection Rating IP67
Key Parameters
Category Description / Value
Product Line Eaton M22 Inductive Sensors
Sensor Type Inductive Proximity Sensor
Housing Diameter 22mm
Sensing Distance Standard M22 sensing range (typically 5-8mm)
Output Type PNP (sourcing output)
Connection Specific connector type per KC02 code
Supply Voltage 10-30V DC
Output Current ≤200 mA
Housing Material Nickel-plated brass or stainless steel
Protection Rating IP67
Key Parameters
Category Description / Value
Product Line Eaton FAK (Control Relays)
Type Modular Control Relay
Contact Configuration Multiple changeover contacts (specific arrangement depends on R/V code)
Coil Voltage Specific voltage to be verified from datasheet (indicated by IY suffix)
Rated Operational Current Typically 6-10A for relay contacts
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals or spring-cage terminals
Standards Compliance IEC/EN 60947-5-1
Key Parameters
Category Description / Value
Product Line Eaton NZMH (Air Circuit Breakers)
Rated Current (Iₙ) 400 A
Number of Poles 3-Pole or 4-Pole versions available
Trip Unit Type Electronic Trip Unit (S1 type)
Rated Operational Voltage (Uₑ) Up to 690 V AC, 50/60 Hz
Rated Insulation Voltage (Uᵢ) 1000 V
Rated Ultimate Short-Circuit Breaking Capacity (Iᶜᵘ) Very high, typically 65 kA to 100 kA at 400V AC (IEC 60947-2)
Protection Functions • Long-time delay (L)
• Short-time delay (S)
• Instantaneous (I)
• Ground-fault (G)
Mounting Fixed mounting or Draw-out version available
Standards Compliance IEC/EN 60947-2
Key Parameters Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 13 A
Fuse Characteristic Quick-Acting (Fast-Blow, Type D)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 32 A
Number of Poles 3-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 3 A
Number of Poles 2-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 230 V AC (Single-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 6 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 2 A
Number of Poles 2-Pole
Tripping Characteristic C-Curve
Rated Operational Voltage (Uₑ) DC Voltage - Specific maximum DC voltage must be confirmed from device datasheet
Application DC circuits only
Breaking Capacity Rated for DC circuits according to relevant standards
Standards Compliance Relevant DC standards
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals