Technical Parameters Category Specification
Model MTL5576
Product Type Safety Relay for Safety Light Curtains & Scanners (OSSD Devices)
Safety Standards IEC 61508, IEC 62061, ISO 13849
Safety Level SIL 3 (IEC 61508) / PL e (ISO 13849)
Input Channels 2 for monitoring OSSD signals from the safety sensor.
Input Type Solid-state OSSD (PNP) signals, typically 24V DC.
Outputs 3 safety relay outputs (force-guided contacts).
Contact Rating (Output) Typically 6 A, 250 V AC / 5 A, 30 V DC
Supply Voltage 24V DC (with a wide range, e.g., 19.2 - 30V DC)
Configuration Via DIP switches for modes like Reset, Muting, and Test.
Key Features
OSSD Monitoring Yes. Continuously monitors both channels for cross-circuit faults and shorts to supply/ground.
Muting Function Configurable to allow temporary, safe suspension of the safety function (e.g., for material handling).
Fault Detection Yes. Detects faults in the sensor, wiring, and internal circuitry.
Status Indication Comprehensive LED indicators for Power, Input Status, Output Status, and Faults.
Diagnostics Clear LED status for easy troubleshooting of the safety loop.
Mounting 35 mm DIN rail.
Operating Temperature -25°C to +55°C / -40°C to +70°C (depending on variant)
Technical Parameters
Category Specification
Model NP44 3AW
Product Type Miniature Circuit Breaker (MCB)
Number of Poles 3 Poles
Rated Current (In) 4 A (This is implied by the "4" in NP44. Other ratings like 6A, 10A, etc., are available in the NP44 frame).
Breaking Capacity 4.5 kA (4.5kA Icn at 400V AC, conforming to IEC/EN 60898-1)
Tripping Characteristic Type A (Instantaneous trip between 2x In and 3x In).
Rated Voltage (Ue) 240/415V AC
Standards IEC/EN 60898-1, IEC/EN 60947-2
Terminal Connection Suitable for both cable and busbar connection.
Mounting Standard 35 mm DIN rail
Key Features
Overload Protection Yes (provided by the thermal bi-metal strip).
Short-Circuit Protection Yes (provided by the electromagnetic solenoid).
Isolation Function Yes, provides safe isolation when in the OFF position.
Technical Parameters
Category Specification
Model / Order Code NZM1-XASFIU
Product Type Molded Case Circuit Breaker (MCCB) with Fixed Mounting and Accessories
Frame Size NZM1 (This frame covers a range of rated currents, e.g., up to 160A or 250A).
Mounting Fixed (designated by "X"). Rated Operational Voltage (Ue) Typically 400/415V AC, 50/60 Hz.
Rated Ultimate Breaking Capacity (Icu) Depends on the specific NZM1 frame size and rating (e.g., 25kA, 36kA, 50kA).
Standards IEC 60947-2
Technical Parameters
Category Specification
Model 02-111040 (EASY-SMART-DISPLAY)
Product Type Small Graphical Operator Interface
Display
Type & Size Monochrome LCD, 1.8 inches
Resolution 128 x 64 pixels
Backlight White LED
Keys 4 tactile function keys
Communication
Interface RS-485
Protocol Modbus RTU (Slave)
Power Supply 24V DC (typical for industrial use)
Electrical Connection Removable screw terminal block
Mounting Panel mount (designed for a cut-out)
Front Panel Rating Typically IP65 (dust-tight and protected against water jets) when properly installed.
Programming Configured using Eaton's EASY-SMART-DISPLAY configuration software.
Technical Parameters
Category Specification
Model PK6522
Product Type Fixed Displacement Hydraulic Gear Pump
Displacement ~22 cm³/rev (cubic centimeters per revolution). This is a common displacement for this model series (e.g., PK652* series with 22 cc/rev). Must be verified from datasheet.
Pressure Rating
Maximum Continuous Pressure Typically in the range of 250 to 300 bar (≈ 3625 to 4350 psi).
Peak Pressure Typically higher, e.g., 315 bar (≈ 4570 psi).
Speed Range
Maximum Speed Typically up to 3000 rpm or higher.
Rotation Typically available in both clockwise and counter-clockwise rotation.
Shaft Type Standard splined or keyed shaft.
Port Connection SAE or metric threaded ports (e.g., SAE 4-bolt).
Fluid Type Mineral-based or synthetic hydraulic oil with appropriate viscosity.
Typical Applications
Mobile Equipment Tractors, combines, forklifts, etc.
Industrial Machinery Machine tools, presses, etc.
Technical Parameters
Category Specification
Model PKZMO-4-T
Product Type Motor Protection Circuit Breaker (MPCB)
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 690V AC
Frame Size 4 (This frame covers a specific range of adjustable current settings, e.g., up to 32A or 40A).
Utilization Category A (For general purpose)
Number of Poles 3-Pole
Protection Functions
Overload Protection Yes, adjustable via a rotary dial (Ir). Based on a thermal bi-metal trip mechanism.
Short-Circuit Protection Yes, fixed magnetic trip setting (Im).
Phase Loss Sensitivity** Yes, inherently provides protection against single-phasing.
Auxiliary Contacts Trip Indicator Contact (T) - 1 NO (Normally Open) contact that closes upon tripping.
Breaking Capacity High breaking capacity according to IEC 60947-2 (e.g., 50kA at 400V).
Standards IEC/EN 60947-2, IEC/EN 60947-4-1
Mounting Standard 35 mm DIN rail
Control Circuit Connection Screw clamp terminals
Technical Parameters
Category Specification
Model 1451E-8517
Product Type Solid-State Multi-Function Timing Relay
Mounting Style Panel Mount with 8-pin octal plug-in base
Time Range 0.1 Second to 100 Hours (widely adjustable)
Supply Voltage 120V AC, 50/60 Hz
Output Configuration DPDT (2 Form C) - Electromechanical Relay Output
Contact Rating (Output) Typically 10A @ 240V AC / 5A @ 28V DC
Timing Functions Multiple functions selectable (e.g., On-Delay, Off-Delay, Interval, etc.)
Repeat Accuracy Typically ±0.5% of setting
Dial Linear or logarithmic scale for time setting
Status Indication LED power and timing status indicator
Operating Temperature -10°C to +55°C (14°F to 131°F)
Agency Approvals UL Listed, CSA Certified
Technical Parameters
Category Specification
Model EPF31P-M530V2O1PR
Product Type Single-Phase Online Double-Conversion UPS
Power Capacity 530 VA / 300 W
Input
Voltage 100-120 VAC (for 120V market) or 200-240 VAC (for 230V market) - Must be verified
Frequency 50/60 Hz Auto-sensing
Output
Voltage 100-120 VAC or 200-240 VAC (regulated to a stable output, e.g., 120V or 230V)
Frequency 50/60 Hz (synchronized to input or internal oscillator in battery mode)
Waveform Pure Sine Wave
Connection Topology Line-Interactive with Double-Conversion Technology
Typical Backup Time Varies based on load, typically several minutes at full load. Extended runtime requires external battery packs.
Communications Communication slot (e.g., for Eaton PR or other network management cards).
Display & Interface LCD or LED status display for system information.
Key Features
Automatic Voltage Regulation (AVR) Yes, corrects under/over voltages without using the battery.
Zero Transfer TimeYes, provides seamless transition between AC and battery power.
Hot-Swappable BatteriesAllows for battery replacement without shutting down the connected equipment.
Technical Parameters Category Specification
Model MTL7766PAC
Product Type I/O System Communication Baseplate / PAC Chassis
Part of System MTL 7700+ I/O System
Primary Function Provides communication and power for up to 8 MTL 77xx series I/O modules.
Communication Protocols Typically EtherNet/IP and Modbus TCP/IP (Dual-port switch). Other variants may support Profibus.
Power Supply Requires a separate 24V DC power supply for the baseplate and its I/O modules.
Number of Slots 8 slots for I/O modules.
Key Features
Hot Swappable Supports hot swapping of I/O modules for maintenance without shutting down the system.
Diagnostics Comprehensive module and network diagnostics with status LEDs.
Intrinsic Safety When populated with MTL IS I/O modules, it provides a certified interface for hazardous areas.
Mounting Designed for DIN rail or panel mounting.
Operating Temperature -40°C to +70°C
Technical Parameters
Category Specification
Model MTL4573
Product Type Configurable Safety Relay for ESPE (e.g., Light Curtains)
Safety Standards IEC 61508, IEC 62061, ISO 13849
Safety Level SIL 3 / PL e
Input Channels 2 for monitoring OSSD signals from the safety sensor.
Input Type Solid-state OSSD (PNP) signals, typically 24V DC.
Outputs 3 safety relay outputs (force-guided contacts).
Contact Rating (Output) 5 A, 250 V AC
Supply Voltage 24V DC (19.2 - 30V DC)
Configuration Via DIP-switches for modes like Reset, Muting, and Test.
Key Features
OSSD Monitoring Yes. Continuously monitors both channels for cross-circuit faults and shorts.
Muting Function Yes. Configurable to allow temporary suspension of the safety function for material handling.
Fault Detection Yes. Detects faults in the sensor, wiring, and internal circuitry.
Status Indication Comprehensive LED indicators for Power, Inputs (CH1/CH2), Outputs, and Faults.
Diagnostics Clear LED status for easy troubleshooting of the safety loop.
Mounting 35 mm DIN rail.
Operating Temperature -25°C to +55°C