Products
Products
home
eaton
ZM1/2-XV4
Parameter Specification / Inference Product Model ZM1/2-XV4 Product Line Eaton ZM (RCCB) Device Type Residual Current Circuit Breaker (RCCB) Number of Poles 2 Poles (1P + N) Rated Current (In) This is not specified in this part of the code. The ZM frame accepts a range of current ratings (e.g., 16A, 25A, 40A, 63A) which is a separate specification. Rated Operational Voltage (Ue) 230 V AC Rated Residual Operating Current (IΔn) 40 mA Type of Residual Current AC (Sensitive to alternating sinusoidal residual currents) Tripping Time Instantaneous (Typically < 300 ms for 1x IΔn, and < 40 ms for 5x IΔn as per standards) Breaking Capacity According to IEC 61009-1 (e.g., 6000 A) Mounting DIN Rail Mount (35 mm) Standards Compliance IEC 61008-1, VDE 0664, etc.

More details >> Request a Quote >>
eaton
MTL4041B
Parameter Specification Product Model MTL4041B Product Line Eaton MTL Signal Conditioners & Isolators Function Single-channel Signal Isolator / Repeater Input Signal 4-20 mA Output Signal Isolated 4-20 mA Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher) Power Supply Typically 20-30 V DC Accuracy Typically better than ±0.1% of span Load Capacity Typically up to 850 Ω (at 20 mA) Line Fault Detection Yes, can be configured for indication on open or short circuit input. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C

More details >> Request a Quote >>
eaton
MTL7787P+
Parameter Specification Product Model MTL7787P+ Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (Example values, MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C

More details >> Request a Quote >>
eaton
MTL7767+
Parameter Specification Product Model MTL7767+ Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (Example values, MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C

More details >> Request a Quote >>
eaton
MTL7782+
Parameter Specification Product Model MTL7782+ Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (Example values, MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C

More details >> Request a Quote >>
eaton
IOP32
Parameter Specification / Inference Product Model IOP32 Product Line Eaton Industrial Control Devices Product Type Illuminated Pushbutton Mounting Hole Diameter 32 mm Protection Rating NEMA 4X / IP65 Contact Block Not included in base model. Must be selected separately Lens Color Not specified in base model. Various colors available Illumination Voltage Not specified in base model. Requires separate selection of lamp holder or LED module Rated Operational Current Depends on the contact block used Operator Material Thermoplastic or metal, designed for durability. Mounting Panel-mounted from the front with a securing nut.

More details >> Request a Quote >>
eaton
MTL7706+
Parameter Specification Product Model MTL7706+ Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (Example values, MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C

More details >> Request a Quote >>
eaton
MTL7743
Parameter Specification Product Model MTL7743 Product Line Eaton MTL Signal Conditioners & Isolators Function Single-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area. Output Signal Isolated 4-20 mA DC signal. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (Example values, MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C

More details >> Request a Quote >>
eaton
MTL7765AC
Parameter Specification Product Model MTL7765AC Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Likely 100-240V AC (Inferred from "AC" suffix. MUST be verified from datasheet). Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C Compliance & Certifications ATEX, IECEx, FM, CSA, etc.

More details >> Request a Quote >>
eaton
MTL788+
Parameter Specification Product Model MTL788+ Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (Example values, MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C

More details >> Request a Quote >>
1 2
··· ···