Products
Products
home
EATON
NZMN2-M160
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMN2-M160 Product Line NZM Rated Current (Iₙ) 160 A Poles 3 Frame Size NZMN2-M Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 160A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 160A terminals)

More details >> Request a Quote >>
EATON
NZMS2-A200
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMS2-A200 Product Line NZM Rated Current (Iₙ) 200 A Poles 3 Frame Size NZMS2-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 200A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 200A terminals) 典型应用 (Typical Applications):

More details >> Request a Quote >>
EATON
NZMN1-A125
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMN1-A125 Product Line NZM Rated Current (Iₙ) 125 A Poles 3 Frame Size NZMN1-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 125A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 125A terminals)

More details >> Request a Quote >>
EATON
NZMC1-A100
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMC1-A100 Product Line NZM Rated Current (Iₙ) 100 A Poles 3 Frame Size NZMC1-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 36 kA / 50 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 100A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles Mechanical Life Tens of thousands of cycles Terminal Torque Refer to official manual (Specific torque for 100A terminals)

More details >> Request a Quote >>
EATON
LZMN1-A160
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number LZMN1-A160 Product Line NZM Rated Current (Iₙ) 160 A Poles 3 Frame Size NZM1-A Rated Operational Voltage (Uₑ) 400/415 V AC (IEC) / 690 V AC Rated Insulation Voltage (Uᵢ) 690 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (I꜀ᵤ) Typically 25 kA / 36 kA @ 400V (Must be verified from datasheet) Trip Unit Type Thermal-Magnetic (Non-Adjustable) Overload Protection (Ir) Fixed at 160A Short-Circuit Protection (Im) Fixed magnetic trip Installation Fixed Type Standards Compliance IEC 60947-2 Electrical Life Several thousand cycles (e.g., 5,000) Mechanical Life Tens of thousands of cycles (e.g., 20,000) Terminal Torque Refer to official manual (Specific torque for 160A terminals)

More details >> Request a Quote >>
EATON
NZMS1-A125
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMS1-A125 Product Line NZM Rated Current (In) 125 A Poles 3 Frame Size NZMS1 Mounting Type Fixed Trip Unit Type Fixed Thermal-Magnetic (TMD) Rated Operational Voltage (Ue) 400/415 V AC 690 V AC Rated Insulation Voltage (Ui) 750 V / 1000 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (Icu) e.g., 36 kA / 50 kA @ 400V (This is a CRITICAL detail that must be verified from the official datasheet) Accessories Can typically be fitted with auxiliary contacts, shunt trips, under-voltage releases, and rotary handles. Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
NZMB1-AF80-NA
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZMB1-AF80-NA Product Line NZM Rated Current (In) 80 A Poles 3 Frame Size NZMB1 Mounting Type Fixed Trip Unit Type Fixed Thermal-Magnetic (TMD) Rated Operational Voltage (Ue) 400/415 V AC 690 V AC Rated Insulation Voltage (Ui) 750 V / 1000 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (Icu) e.g., 25 kA / 36 kA @ 400V (Crucial to verify from datasheet) Accessories None (Can typically be field-equipped with auxiliary contacts, shunt trips, etc.) Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
NZM2/3-XA208-250AC/DC
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number NZM2/3-XA208-250AC/DC Product Line NZM Rated Current (In) 208 A (Set at the trip unit) Frame Size NZM2 Poles 3 Trip Unit Type Electronic (MPU type) Rated Operational Voltage (Ue) 400/415 V AC 690 V AC Rated Insulation Voltage (Ui) 750 V / 1000 V AC Rated Frequency 50/60 Hz Rated Ultimate Breaking Capacity (Icu) e.g., 50 kA / 65 kA @ 400V (Must be verified from datasheet) Protection Functions L - Long-time (Ir, tr) S - Short-time (Isd, tsd) I - Instantaneous (Ii) G - Ground-fault (Ig, tg) Adjustability All protection settings (Ir, Isd, Ii, Ig, time delays) are fully adjustable. Accessory Supply Voltage 250 V AC / 250 V DC (For built-in shunt trip, under-voltage release, etc.) Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
PKZM0-16
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number PKZM0-16 Product Line PKZ Rated Operational Current for Motors (Ie) 16 A (Max) Setting Range for Thermal Overload Approx. 12 - 16 A (Adjustable) Poles (Main Circuit) 3 Rated Operational Voltage (Ue) 400 V / 690 V AC Rated Insulation Voltage (Ui) 690 V / 750 V AC Rated Ultimate Breaking Capacity (Icu) 50 kA / 100 kA @ 400V AC (Must be verified from datasheet) Tripping Class Class 10 Short-Circuit Protection Setting Fixed (approx. 12 x Ie) Auxiliary Contacts Compatible with accessory modules (e.g., PKZM0-1X) Mounting DIN Rail (35 mm) Standards Compliance IEC/EN 60947-2, IEC/EN 60947-4-1

More details >> Request a Quote >>
EATON
PKZM0-25
Technical Specifications Parameter Specification / Typical Value Manufacturer / Brand Eaton Model Number PKZM0-25 Product Line PKZ (Moeller Series) Rated Operational Current for Motors (Ie) 25 A (Max) Setting Range for Thermal Overload Approx. 18 - 25 A (adjustable via a dial) Poles (Main Circuit) 3 Rated Operational Voltage (Ue) 690 V AC Rated Insulation Voltage (Ui) 690 V / 750 V AC Rated Ultimate Breaking Capacity (Icu/@400V) Typically 50 kA or 100 kA (Must be verified from the official datasheet) Tripping Class Class 10 (Standard for general motors, trips within 10 seconds at 7.2 x Ir) Short-Circuit Protection Setting Fixed, based on the device design (typically around 12 x Ie or higher) Auxiliary Contacts Can typically be fitted with one or more auxiliary contact modules (e.g., PKZM0-1X) to signal the trip status. Mounting DIN Rail Mount (35mm) Standards Compliance IEC/EN 60947-2, IEC/EN 60947-4-1

More details >> Request a Quote >>
1 2
··· ···