Products
Products
home
EATON
NZMH4-AE1250
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, NZM Series Model Number NZMH4-AE1250 Number of Poles 4-Pole Rated Current 1250 A (Frame Size) Rated Operational Voltage (Ue) Up to 690V AC Rated Ultimate Breaking Capacity (Icu) Typically 65 kA / 85 kA at 415V AC (Confirm with specific datasheet) Trip Unit Type AE - Advanced Electronic Trip Unit with LCD Display Protection Functions L - Long-time Delay (Overload) S - Short-time Delay (Short-Circuit) I - Instantaneous (Short-Circuit) G - Ground-Fault (Earth Leakage) Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
E125E
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, E-Frame Series Model Number E125E Rated Current 125 A (Frame Size) Pole Configurations Available in 1, 2, and 3-pole versions (specific model varies) Rated Voltage 120/240V AC for 1-2 poles 240V AC for 3 poles Interrupting Rating 10 kA / 14 kA / 22 kA (Depending on specific version and certification) Trip Characteristics Thermal-Magnetic • Thermal Trip: Inverse time delay for overloads • Magnetic Trip: Instantaneous for short-circuits Standards Compliance UL 489, CSA C22.2 No. 5

More details >> Request a Quote >>
EATON
NZMN2-A125
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, NZM Series Model Number NZMN2-A125 Number of Poles 2-Pole Rated Current 125 A (Frame Size) Rated Operational Voltage (Ue) Up to 480V AC Rated Insulation Voltage (Ui) 690V AC Rated Ultimate Breaking Capacity (Icu) Typically 25 kA / 35 kA at 480V AC (Confirm with specific datasheet) Trip Unit Type Type A - Adjustable Electronic Trip Unit Protection Functions L - Long-time Delay (Overload) S - Short-time Delay (Short-Circuit) I - Instantaneous (Short-Circuit) Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
NZM2
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, NZM Series Model Designation NZM2 Frame Size Compact Frame (Specific current ratings typically up to 160A) Pole Configurations Available in 2, 3, and 4-pole versions Rated Operational Voltage (Ue) Up to 690V AC Rated Insulation Voltage (Ui) 750V AC / 800V AC Breaking Capacity High interrupting rating (Typically 25kA to 50kA depending on specific model and voltage) Trip Unit Options Available with Thermal-Magnetic (TMD) or Electronic (A/ME) trip units Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
ETR4-11-A
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, ETR4 Series Model Number ETR4-11-A Poles 3-Pole Trip Class Class 10 Current Setting Range 0.11 - 0.16 A Rated Operational Voltage (Ue) 690V AC Rated Insulation Voltage (Ui) 1000V AC Ambient Temperature Range -25°C to +60°C (Derating may apply above +50°C) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14 Mounting Snap-on mounting to compatible Eaton DIL contactors Auxiliary Contacts 1 NO (95-96) + 1 NC (97-98) - Convertible Reset Mode Manual reset (Automatic reset optional)

More details >> Request a Quote >>
EATON
DILM7-10C
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, DILM Series Model Number DILM7-10C Rated Operational Current (Ie) 7 A at AC-3, 400V Thermal Current (Ith) 7 A Poles (Main Circuit) 3 (Normally Open) Auxiliary Contacts 1 NO (Normally Open) - Fixed Rated Operational Voltage (Ue) Up to 690V AC Control Coil Voltage "C" denotes a standard DC voltage range. The specific voltage must be ordered (e.g., 24V DC, 110V DC). Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running AC-1: Non-inductive or slightly inductive loads Motor Rating (at 400V AC) 3 kW / 4 HP Mechanical Life ~ 15 million operations Electrical Life (AC-3) ~ 1.5 million operations Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14 Terminal Type Cage Clamp / Screw Clamp

More details >> Request a Quote >>
EATON
DILA-22C
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, DILA Series Model Number DILA-22C Rated Operational Current (Ie) 22 A at AC-3, 400V Thermal Current (Ith) 22 A Poles (Main Circuit) 3 (Normally Open) Auxiliary Contacts 1 NO (Normally Open) - Fixed Rated Operational Voltage (Ue) Up to 690V AC Control Coil Voltage "C" denotes a standard DC voltage range. The specific voltage must be ordered (e.g., 24V DC, 110V DC). Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running AC-1: Non-inductive or slightly inductive loads Motor Rating (at 400V AC) 11 kW / 15 HP Mechanical Life ~ 15 million operations Electrical Life (AC-3) ~ 1.5 million operations Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14 Terminal Type Cage Clamp / Screw Clamp

More details >> Request a Quote >>
EATON
HI11-P1/P3Z
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, HI System (formerly Moeller) Model Number HI11-P1/P3Z Power Supply Voltage 24-240V AC/DC (Wide range) Output Contact 1 CO (Changeover) - 1 NO + 1 NC Contact Rating: Typically 8A resistive at 250V AC Timing Ranges Multiple ranges selectable (e.g., 0.1s-10h, depending on function) Functions Multiple timing functions selectable via rotary switch: • On-delay (1) • Off-delay (2) • Star-delta (3) • Pulse generator (4) • On/off cycling (5) • Single shot (6) Accuracy ±0.5% of set value ±20ms Mounting DIN Rail (35mm) Display Digital display with status LEDs Standards Compliance IEC/EN 61812-1, UL 508, CSA C22.2 No. 14

More details >> Request a Quote >>
EATON
NZM2-XRD208-240AC
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, NZM Series Model Number NZM2-XRD208-240AC Frame Size NZM2 (Compact Frame, specific current rating up to 160A) Mounting Type Draw-Out Version (Fixed mounting in a draw-out frame) Rated Operational Voltage (Ue) 208-240V AC Trip Unit Type Electronic Trip Unit (Specific type indicated by "X" in XRD) Rated Current 208A (Indicated by "208" in the model number) Control Voltage 240V AC (For the operating mechanism/shunt trip, etc.) Breaking Capacity High interrupting rating (Specific kA rating depends on the NZM2-XR platform) Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
LH-50/2/C
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, LH Series Model Number LH-50/2/C Fuse Type & Rating LH Cartridge Fuse Rated Current: 50 A Number of Poles / Quantity 2 pieces (2-pole set) Time-Current Characteristic Type C (General Purpose) Rated Voltage 500V AC / 250V DC Breaking Capacity Medium to High (Specific rating depends on certification) Standards Compliance IEC 60269-1 and related national standards Fuse Dimension 10 x 38 mm or 14 x 51 mm (Depending on specific LH type) Mounting Requires compatible fuse holder

More details >> Request a Quote >>
1 2
··· ···