Products
Products
home
eaton
FAZ-D15/3-NA
Parameter Description Specification Product Series FAZ Series Circuit Breaker Rated Current In 15A Number of Poles 3 Poles Rated Voltage AC 480V AC (600V AC maximum) Breaking Capacity Icn 10kA at 240V AC 5kA at 480V AC Tripping Characteristic D Curve (High inrush, 10-20x In) Mounting 35mm DIN Rail Connection Terminals Screw terminals Terminal Capacity Up to 16mm² (AWG 6) Operating Temperature -25°C to +60°C Mechanical Life >20,000 operations Standards & Approvals UL 1077, CSA C22.2, CE Weight Approximate 0.4 kg

More details >> Request a Quote >>
eaton
NZMN2-A160
Parameter Description Specification Product Series NZM Series Molded Case Circuit Breaker Frame Size NZMN2 160A frame size Rated Current In 160A (adjustable)* Number of Poles 3 Poles Rated Voltage AC 690V AC Rated Frequency 50/60 Hz Breaking Capacity Icu 50kA at 415V AC Tripping Characteristic Electronic trip unit Mounting Fixed or plug-in version Connection Terminals Front connection Standards & Approvals IEC 60947-2, CE, UL Ambient Temperature Operation -25°C to +60°C

More details >> Request a Quote >>
eaton
NZM2/3-XU110-130AC
Parameter Description Specification Product Series NZM Series Undervoltage Release Accessory Compatible Breakers NZM2, NZM3 Molded Case Circuit Breakers Rated Control Voltage 110-130V AC Operating Range Voltage 70-130% of rated voltage Tripping Delay Typically 0.5-3 seconds (adjustable) Power Consumption Low power design Mounting Installation Direct mounting on compatible breakers Connection Terminals Screw-type terminals Ambient Temperature Operation -25°C to +60°C Protection Degree Enclosure IP20 Standards & Approvals IEC 60947-2, CE, UL

More details >> Request a Quote >>
eaton
P3-100/EA/SVB
Parameter Description Specification Product Series P3 Series Residual Current Circuit Breaker Rated Current In 100A Sensitivity IΔn 30mA (High sensitivity) Number of Poles 4 Poles (3P + N) Rated Voltage AC 400V Rated Frequency 50/60 Hz Breaking Capacity According to P3 series standards Tripping Characteristic Type A (AC and pulsating DC) Mechanical Life > 20,000 operations Electrical Life > 4,000 operations Mounting 35mm DIN Rail Connection Terminals Suitable for rigid and flexible conductors Operating Temperature -25°C to +60°C Standards & Approvals IEC 61008, CE

More details >> Request a Quote >>
eaton
NZMN2-A250
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, NZM Series Model Number NZMN2-A250 Number of Poles 2-Pole Rated Current (In) 250 A Rated Operational Voltage (Ue) 400/415V AC, 50/60 Hz Rated Insulation Voltage (Ui) 500V AC Rated Impulse Withstand Voltage (Uimp) 6 kV Breaking Capacity (Icu) Typically 25 kA (Please confirm with the local datasheet for specific voltage ratings) Tripping Characteristic Type A Mechanical Durability 20,000 operations Electrical Durability 5,000 operations at rated current (In) Mounting Standard 35mm DIN Rail (EN 60715) Standards Compliance IEC/EN 60898-1, IEC/EN 60947-2 Termination Suitable for busbar or cable lug connection. Tightening torques as per manufacturer's specification. Protection Degree (IP Code) IP20 (when installed in a suitable enclosure)

More details >> Request a Quote >>
eaton
DILM25-10N
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, DILM Series Model Number DILM 25-10N Rated Operational Current (Ie) 25 A at AC-3, 400V Rated Thermal Current (Ith) 25 A Poles (Main Circuit) 3 (Normally Open) Auxiliary Contacts 1 NO (Normally Open) + 1 NC (Normally Closed) - Convertible Rated Operational Voltage (Ue) Up to 690V AC Control Coil Voltage "N" denotes a standard AC voltage range (e.g., 110V, 230V, 400V, etc.). The specific voltage must be ordered (e.g., DILM25-10 230V AC). Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running (~ 2.5 million operations at 25A) AC-1: Non-inductive or slightly inductive loads (~ 10 million operations) Motor Rating (at 400V AC) 15 kW / 20 HP Short-Circuit Protection Must be coordinated with Type a (gG/gL) fuses or circuit breakers. Recommended max. fuse: 63A Mechanical Life ~ 15 million operations Electrical Life (AC-3) ~ 2.5 million operations Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14 Terminal Type Cage Clamp / Screw Clamp

More details >> Request a Quote >>
eaton
FAZ-C10/3
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, FAZ Series (Bussmann) Model Number FAZ-C10/3 Fuse Class & Rating Class CC Rated Current: 10 A Rated Voltage: 600V AC Number of Poles / Quantity 3 pieces (Typically supplied as a 3-pole set for a 3-phase application) Type Fast-Acting (Non-Time-Delay) Rated Voltage 600V AC / 300V DC Rated Breaking Capacity (Interrupting Rating) 200 kA AC (200,000 Amps) at 600V AC Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4, IEC 60269-1 (Optional) Electrical Characteristics Current-Limiting: Yes Melting I²t (10A): Approximately 1.5 A²s (Refer to official datasheet for precise values) Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length) Mounting / Fuse Holder Requires a compatible Class CC fuse holder or fuse block (e.g., Eaton FHCC100, KRP-C-100SP)

More details >> Request a Quote >>
eaton
P1-25/EA/SVB
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, P1 Series (Domae) Model Number P1-25/EA/SVB Rated Current (In) 25 A Number of Poles 2-Pole (1P + N) Rated Operational Voltage (Ue) 230V AC (Single-Phase + Neutral) Rated Insulation Voltage (Ui) 400V AC Breaking Capacity (Icn) 25 kA (25,000 A) at 230/400V AC Tripping Characteristic Type A (Instantaneous trip: 2-3 x In) Mechanical Life 20,000 operations Electrical Life 10,000 operations Mounting Standard 35mm DIN Rail (EN 60715) Auxiliary Indication EA - Standard ON/OFF flag indicator Terminal Type SVB - Shrouded Terminal Barrier (Finger Protection) for enhanced safety. Suitable for solid and stranded conductors. Standards Compliance IEC/EN 60898-1

More details >> Request a Quote >>
eaton
NZMN3-AE630
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, NZM Series Model Number NZMN3-AE630 Rated Current (In) 630 A (This is the frame size. The adjustable electronic trip unit can be set to a specific value up to 630A). Rated Ultimate Breaking Capacity (Icu) Typically 50 kA / 65 kA at 415V AC (Please confirm with the specific datasheet for your voltage and certification). Number of Poles 3-Pole Rated Operational Voltage (Ue) Up to 690V AC Trip Unit Type AE - Advanced Electronic Trip Unit with LCD Display Protection Functions L - Long-time Delay (Overload) S - Short-time Delay (Short-Circuit) I - Instantaneous (Short-Circuit) G - Ground-Fault (Earth Leakage) Adjustable Settings All protection functions (L, S, I, G) are fully adjustable for current and time delay, allowing for precise selective coordination. Standard Compliance IEC/EN 60947-2

More details >> Request a Quote >>
eaton
DILM25-01C
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, DILM Series Model Number DILM25-01C Rated Operational Current (Ie) 25 A at AC-3, 400V Rated Thermal Current (Ith) 25 A Poles (Main Circuit) 3 (Normally Open) Auxiliary Contacts 1 NO (Normally Open) - Fixed Rated Operational Voltage (Ue) Up to 690V AC Control Coil Voltage "C" denotes a standard DC voltage range. The specific voltage must be ordered (e.g., 24V DC, 110V DC). Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running (~ 1.5 million operations) AC-1: Non-inductive or slightly inductive loads (~ 10 million operations) Motor Rating (at 400V AC) 15 kW / 20 HP Short-Circuit Protection Must be coordinated with fuses or circuit breakers. Mechanical Life ~ 15 million operations Electrical Life (AC-3) ~ 1.5 million operations Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14 Terminal Type Cage Clamp / Screw Clamp

More details >> Request a Quote >>
1 2
··· ···