Parameter Description Specification
Product Series DILM Series Contactor Relay
Generation Enhanced "A" Version Improved electrical endurance
Rated Operational Current AC-1 (Resistive Load) 32 A at 690V
Motor Rating AC-3 (Squirrel Cage Motor) 15 kW at 400V/50 Hz
Resistive Load Rating AC-1 22 kW at 400V
Number of Poles Main Circuits 4 NO (Normally Open)
Rated Insulation Voltage 1000 V
Rated Operational Voltage Up to 690 V AC
Coil Control Voltage AC Operation 230V AC, 50/60 Hz*
Electrical Endurance AC-3 > 2 million operations
Mechanical Durability > 15 million operations
Mounting Method 35 mm DIN rail
Connection Type Spring-loaded cage clamp
Terminal Capacity Main Circuits Up to 10 mm²
Ambient Temperature Operation -25°C to +60°C
Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC
Parameter Description Specification
Product Series DILM Series Contactor Relay
Rated Operational Current AC-1 (Resistive Load) 25 A at 690V
Motor Rating AC-3 (Squirrel Cage Motor) 11 kW at 400V/50 Hz
Resistive Load Rating AC-1 18.5 kW at 400V
Number of Poles Main Circuits 4 NO (Normally Open)
Rated Insulation Voltage 1000 V
Rated Operational Voltage Up to 690 V AC
Coil Control Voltage AC Operation 230V AC, 50/60 Hz*
Electrical Endurance AC-3 > 1 million operations
Mechanical Durability > 10 million operations
Mounting Method 35 mm DIN rail
Connection Type Spring-loaded cage clamp
Terminal Capacity Main Circuits Up to 10 mm²
Ambient Temperature Operation -25°C to +60°C
Weight Approximate 0.6 kg
Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC
Parameter Description Specification
Product Series DILM Series Contactor Relay
Rated Operational Current AC-1 (Resistive Load) 22 A at 690V
Motor Rating AC-3 (Squirrel Cage Motor) 7.5 kW at 400V/50 Hz
Resistive Load Rating AC-1 15 kW at 400V
Number of Poles Main Circuits 4 NO (Normally Open)
Rated Insulation Voltage 1000 V
Rated Operational Voltage Up to 690 V AC
Coil Control Voltage AC Operation 230V AC, 50/60 Hz*
Electrical Endurance AC-3 > 1 million operations
Mechanical Durability > 10 million operations
Mounting Method 35 mm DIN rail
Connection Type Spring-loaded cage clamp
Terminal Capacity Main Circuits Up to 10 mm²
Ambient Temperature Operation -25°C to +60°C
Weight Approximate 0.55 kg
Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC
Parameter Description Specification
Product Series EMR6 Series Electronic Motor Protection Relay
Model Variant F500 Protection relay configuration
Rated Current Setting Range 0.4-6.3A (adjustable)*
Power Supply Operating Voltage 24-240V AC/DC (wide range)
Motor Power Range Corresponding Rating Up to 3kW at 400V*
Protection Functions Overload Protection Yes (inverse time characteristic)
Phase Failure Yes
Phase Imbalance Yes
Locked Rotor Yes
Undercurrent Yes
Control Inputs Digital Inputs Multiple programmable inputs
Output Relays Control Relays Programmable relay outputs
Mounting Installation 35mm DIN rail
Display Indication LED status indicators
Ambient Temperature Operation -25°C to +60°C
Standards & Approvals IEC/EN 60947-4-1, UL 508, CE
Parameter Description Specification
Product Series NZM2 Series Circuit Breaker
Accessory Type XRD24 Undervoltage Release
Rated Current Main Breaker 30A
Rated Voltage Operational 690V AC maximum
Undervoltage Release Control Voltage 24V DC
Tripping Delay Undervoltage Typically 0.5-2 seconds
Release Power Consumption Operating Low power design
Breaking Capacity Icu According to NZM2 ratings
Poles Main Circuit 3 Poles (typical)
Mounting Installation Fixed or plug-in version
Connection Terminals Screw-type terminals
Ambient Temperature Operation -25°C to +60°C
Standards & Approvals IEC 60947-2, UL 489, CE
Parameter Description Specification
Product Series DILM Series Contactor Relay
Rated Operational Current AC-1 9A
Rated Operational Voltage AC 250V / 400V
Motor Rating AC-3 2.2kW at 230V
4kW at 400V
Number of Poles Main Contacts 1 NO (Normally Open)
Coil Control Voltage Standard 230V AC, 50/60 Hz*
Electrical Endurance Mechanical > 10 million operations
Mechanical Durability Electrical > 1 million operations (at rated current)
Mounting Method 35mm DIN rail
Connection Type Screw terminals
Terminal Capacity Up to 2.5mm²
Ambient Temperature Operation -25°C to +60°C
Weight Approximate 0.15kg
Standards & Approvals IEC/EN 60947-4-1, CE
Parameter Description Specification
Product Series FAZ Series Circuit Breaker
Rated Current In 4A
Number of Poles 1 Pole
Rated Voltage AC 240V/480V AC
Breaking Capacity Icn 10kA at 240V AC
5kA at 480V AC
Tripping Characteristic D Curve (High inrush)
Mounting 35mm DIN Rail
Connection Terminals Screw terminals
Terminal Capacity Up to 16mm²
Operating Temperature -25°C to +60°C
Standards & Approvals UL 1077, CSA C22.2, CE
Mechanical Life >20,000 operations
Parameter Description Specification
Product Series P3 Series Residual Current Circuit Breaker
Rated Current In 63A
Sensitivity IΔn 30mA (High sensitivity)
Number of Poles 4 Poles (3P + N)
Rated Voltage AC 400V
Rated Frequency 50/60 Hz
Breaking Capacity According to P3 series standards
Tripping Characteristic Type AC (Alternating Current)
Mechanical Life > 20,000 operations
Electrical Life > 4,000 operations
Mounting 35mm DIN Rail
Connection Terminals Suitable for rigid and flexible conductors
Operating Temperature -25°C to +60°C
Standards & Approvals IEC 61008, CE
Parameter Description Specification
Product Series Eaton Circuit Breaker T0 Series
Rated Current In 20A
Number of Poles 2 Poles
Rated Voltage AC 240V/415V
Breaking Capacity Icn 6kA at 230/400V AC
Tripping Characteristic Type C (Medium inrush)
Mounting 35mm DIN Rail
Connection Terminals Screw terminals
Terminal Capacity Up to 25mm²
Operating Temperature -25°C to +60°C
Mechanical Life > 20,000 operations
Electrical Life > 10,000 operations
Standards & Approvals IEC 60898, CE
Parameter Description Specification
Product Series ESR5 Series Electronic Motor Protection Relay
Model Variant NV3-30 Specific configuration
Rated Current Setting Range 0.1-30A (adjustable)
Power Supply Operating Voltage 24-240V AC/DC (wide range)
Motor Power Range Corresponding Rating Up to 15kW at 400V
Protection Functions Overload Protection Yes (inverse time characteristic)
Phase Failure Yes
Phase Imbalance Yes
Locked Rotor Yes
Undercurrent Yes
Earth Fault Optional
Control Inputs Digital Inputs 3 programmable inputs
Output Relays Control Relays 2 programmable relay outputs
Communication Interface Optional communication modules
Mounting Installation 35mm DIN rail
Display Indication LED status indicators
Ambient Temperature Operation -25°C to +60°C
Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, cULus