Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 63 A
Number of Poles 3-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 6 A
Number of Poles Typically 1-Pole or 2-Pole (must be confirmed from datasheet)
Tripping Characteristic C-Curve
Rated Operational Voltage (Uₑ) DC Voltage - The specific maximum DC voltage (e.g., 60V DC, 125V DC) must be confirmed from the device datasheet, as it differs from AC ratings.
Breaking Capacity Rated for DC circuits according to relevant standards.
Standards Compliance IEC/EN 60898-1 (or relevant DC standard)
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Connection Screw terminals.
Key Parameters
Category Description / Value
Product Line Eaton FAZT (Fuse Switch Disconnectors)
Rated Current (Iₙ) 32 A (for switch and fuses)
Number of Poles 1 Pole + Neutral (1P+N)
Fuse Type Time-Delay (Type C), 10x38mm or 14x51mm DIN fuse (to be confirmed from datasheet)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V / 690 V
Utilization Category AC-22B or AC-23B (for switching mixed loads including motor loads)
Switch Function Load switching and isolation
Protection Via external fuses
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 10 A
Fuse Characteristic Quick-Acting (Fast-Blow, Type B)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 63 A
Fuse Characteristic Time-Delay (Slow-Blow, Type C)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/3" size code)
Fuse Size/Dimension 14 x 51 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 10 A
Fuse Characteristic Time-Delay (Slow-Blow, Type C)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 3 A
Fuse Characteristic Time-Delay (Slow-Blow, Type C)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 0.5 A (500 mA)
Fuse Characteristic Time-Delay (Slow-Blow, Type C)
Rated Voltage (Uₑ) 250 V AC (as indicated by "/1" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 250V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton BZM (Explosion-Proof Enclosures)
Type Explosion-Proof Control Station / Operator Station
Body Material Typically Cast Aluminum or other non-corrosive, non-sparking material.
Hazardous Location Classifications Certified for Class I, Division 1, Class II, Division 1, and Class III groups (Exact certification must be verified from product documentation).
Enclosure Rating Typically NEMA 4X (Weatherproof and Corrosion-Resistant)
Control Devices Contains integrated control components (e.g., push buttons, switches, lights) as specified by the "U3N-3" code.
Conduit Entries Multiple threaded openings for cable entry.
Window / Cover Transparent, impact-resistant window for viewing indicators, with a bolted cover to maintain explosion-proof integrity.
Key Parameters
Category Description / Value
Product Line Eaton NZMN3 Accessories
Compatible Breakers NZMN3 series air circuit breakers of the specified frame size (Frame 4).
Function Undervoltage Release (UVR)
Rated Control Supply Voltage (Us) 400-415V AC / 500V AC (as indicated by "A500" suffix). The exact voltage must be confirmed by the order code sticker on the device itself.
Mounting Mounts directly onto the compatible NZMN3 breaker.
Operation The breaker can only be closed when the supply voltage is present and above the trip threshold. It automatically trips when the voltage drops below the threshold or is lost.