Key Parameters
Category Description / Value
Product Line Eaton FAK (Control Relays)
Type Modular Control Relay
Contact Configuration Multiple changeover contacts (specific arrangement depends on R/V code)
Coil Voltage Specific voltage to be verified from datasheet (indicated by IY suffix)
Rated Operational Current Typically 6-10A for relay contacts
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals or spring-cage terminals
Standards Compliance IEC/EN 60947-5-1
Key Parameters
Category Description / Value
Product Line Eaton NZMH (Air Circuit Breakers)
Rated Current (Iₙ) 400 A
Number of Poles 3-Pole or 4-Pole versions available
Trip Unit Type Electronic Trip Unit (S1 type)
Rated Operational Voltage (Uₑ) Up to 690 V AC, 50/60 Hz
Rated Insulation Voltage (Uᵢ) 1000 V
Rated Ultimate Short-Circuit Breaking Capacity (Iᶜᵘ) Very high, typically 65 kA to 100 kA at 400V AC (IEC 60947-2)
Protection Functions • Long-time delay (L)
• Short-time delay (S)
• Instantaneous (I)
• Ground-fault (G)
Mounting Fixed mounting or Draw-out version available
Standards Compliance IEC/EN 60947-2
Key Parameters Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 13 A
Fuse Characteristic Quick-Acting (Fast-Blow, Type D)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 32 A
Number of Poles 3-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 3 A
Number of Poles 2-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 230 V AC (Single-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 6 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 2 A
Number of Poles 2-Pole
Tripping Characteristic C-Curve
Rated Operational Voltage (Uₑ) DC Voltage - Specific maximum DC voltage must be confirmed from device datasheet
Application DC circuits only
Breaking Capacity Rated for DC circuits according to relevant standards
Standards Compliance Relevant DC standards
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 4 A
Number of Poles 2-Pole
Tripping Characteristic C-Curve
Rated Operational Voltage (Uₑ) DC Voltage - Specific maximum DC voltage must be confirmed from device datasheet (e.g., 60V DC, 125V DC)
Application DC circuits only
Breaking Capacity Rated for DC circuits according to relevant standards
Standards Compliance Relevant DC standards
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 10 A
Number of Poles 3-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 6-10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Parameter Specification
Product Line Eaton PLD RCBO Series
Rated Current 6A
Poles 1P + N (2-pole)
Tripping Characteristic C-Curve (5-10×Iₙ)
Residual Current 30mA
Rated Voltage 230V AC
Breaking Capacity Typically 6kA (IEC 60898)
Standards IEC 61009-1
Mounting DIN Rail (35mm)
Key Parameters
Category Description / Value
Product Line Eaton PLD9 (Miniature Circuit Breakers)
Rated Current (Iₙ) 10 A
Number of Poles Typically 1-Pole (other configurations available)
Tripping Characteristic Standard Characteristic (typically C-Curve)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals