Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Designation NZM2
Frame Size Compact Frame (Specific current ratings typically up to 160A)
Pole Configurations Available in 2, 3, and 4-pole versions
Rated Operational Voltage (Ue) Up to 690V AC
Rated Insulation Voltage (Ui) 750V AC / 800V AC
Breaking Capacity High interrupting rating (Typically 25kA to 50kA depending on specific model and voltage)
Trip Unit Options Available with Thermal-Magnetic (TMD) or Electronic (A/ME) trip units
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, ETR4 Series
Model Number ETR4-11-A
Poles 3-Pole
Trip Class Class 10
Current Setting Range 0.11 - 0.16 A
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 1000V AC
Ambient Temperature Range -25°C to +60°C (Derating may apply above +50°C)
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Mounting Snap-on mounting to compatible Eaton DIL contactors
Auxiliary Contacts 1 NO (95-96) + 1 NC (97-98) - Convertible
Reset Mode Manual reset (Automatic reset optional)
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM7-10C
Rated Operational Current (Ie) 7 A at AC-3, 400V
Thermal Current (Ith) 7 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts 1 NO (Normally Open) - Fixed
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage "C" denotes a standard DC voltage range. The specific voltage must be ordered (e.g., 24V DC, 110V DC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 3 kW / 4 HP
Mechanical Life ~ 15 million operations
Electrical Life (AC-3) ~ 1.5 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Cage Clamp / Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILA Series
Model Number DILA-22C
Rated Operational Current (Ie) 22 A at AC-3, 400V
Thermal Current (Ith) 22 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts 1 NO (Normally Open) - Fixed
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage "C" denotes a standard DC voltage range. The specific voltage must be ordered (e.g., 24V DC, 110V DC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running
AC-1: Non-inductive or slightly inductive loads
Motor Rating (at 400V AC) 11 kW / 15 HP
Mechanical Life ~ 15 million operations
Electrical Life (AC-3) ~ 1.5 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Cage Clamp / Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, HI System (formerly Moeller)
Model Number HI11-P1/P3Z
Power Supply Voltage 24-240V AC/DC (Wide range)
Output Contact 1 CO (Changeover) - 1 NO + 1 NC
Contact Rating: Typically 8A resistive at 250V AC
Timing Ranges Multiple ranges selectable (e.g., 0.1s-10h, depending on function)
Functions Multiple timing functions selectable via rotary switch:
• On-delay (1)
• Off-delay (2)
• Star-delta (3)
• Pulse generator (4)
• On/off cycling (5)
• Single shot (6)
Accuracy ±0.5% of set value ±20ms
Mounting DIN Rail (35mm)
Display Digital display with status LEDs
Standards Compliance IEC/EN 61812-1, UL 508, CSA C22.2 No. 14
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZM2-XRD208-240AC
Frame Size NZM2 (Compact Frame, specific current rating up to 160A)
Mounting Type Draw-Out Version (Fixed mounting in a draw-out frame)
Rated Operational Voltage (Ue) 208-240V AC
Trip Unit Type Electronic Trip Unit (Specific type indicated by "X" in XRD)
Rated Current 208A (Indicated by "208" in the model number)
Control Voltage 240V AC (For the operating mechanism/shunt trip, etc.)
Breaking Capacity High interrupting rating (Specific kA rating depends on the NZM2-XR platform)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, LH Series
Model Number LH-50/2/C
Fuse Type & Rating LH Cartridge Fuse
Rated Current: 50 A
Number of Poles / Quantity 2 pieces (2-pole set)
Time-Current Characteristic Type C (General Purpose)
Rated Voltage 500V AC / 250V DC
Breaking Capacity Medium to High (Specific rating depends on certification)
Standards Compliance IEC 60269-1 and related national standards
Fuse Dimension 10 x 38 mm or 14 x 51 mm (Depending on specific LH type)
Mounting Requires compatible fuse holder
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PKZM0 Series
Model Number PKZM0-20
Rated Operational Current (Ie) 20 A
Rated Current Setting (Ir) Adjustable, typically from 0.1A to 20A (or a specific range within this)
Poles 3-Pole
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 690V AC
Utilization Category AC-3 (Squirrel cage motor: Starting, switching off during running)
Motor Power Rating (at 400V AC) 9 kW / 12 HP (Approximate)
Short-Circuit Breaking Capacity (Icu) Typically 50 kA at 400V AC (Confirm with specific datasheet)
Trip Class Class 10 (Standard for motor protection)
Standards Compliance IEC/EN 60947-2, IEC/EN 60947-4-1
Mounting DIN Rail (35mm)
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, SL7 Series
Model Number SL7-100-L-RYG-24LED
Mounting Diameter 30 mm (Cut-out: Ø30.5 mm)
Function Illuminated Pushbutton / Indicator Light
Lens Type Multi-lens (RYG) - Red, Yellow, Green
Operating Voltage 24V DC
Light Source LED (Long-life, low power consumption)
Contact Block 1 NO (Normally Open) pushbutton contact (Typically)
Protection Degree IP65 (Front panel, when properly mounted)
Mounting Panel Mount from the front with integrated snap-in mechanism
Standards Compliance IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, LZM2 Series
Model Number LZM2-A160
Rated Current 160 A (Frame Size)
Poles 3-Pole
Rated Operational Voltage (Ue) Up to 690V AC
Rated Insulation Voltage (Ui) 800V AC
Trip Unit Type Type A - Adjustable Electronic Trip Unit
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
Breaking Capacity (Icu) High interrupting capacity (e.g., 35kA, 50kA, or 65kA depending on specific rating and voltage - confirm with datasheet)
Standards Compliance IEC 60947-2