Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-D3/2
Fuse Class & Rating Class D
Rated Current: 3 A
Rated Voltage: 600V AC / 300V DC
Number of Poles / Quantity 2 pieces (2-pole set)
Type Time-Delay (Dual-Element)
Rated Voltage 600V AC / 300V DC
Interrupting Rating 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-10 (Class D), CSA C22.2 No. 248.10
Electrical Characteristics Current-Limiting: Yes
Time-Delay: Can withstand 500% of rated current for several seconds
Physical Dimensions Body: 1-1/4" x 2-1/4" (31.8mm diameter x 57.2mm length) - Edison Base
Mounting / Fuse Holder Requires compatible Class D fuse holder or fuse block
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PL9 Series
Model Number PL9-C40/2
Fuse Standard & Rating IEC gG (General Application)
Rated Current: 40 A
Number of Poles / Quantity 2 pieces (2-pole set)
Rated Voltage 500V AC
Breaking Capacity 50 kA (50,000 A) at 500V AC
Standards Compliance IEC 60269-1, IEC 60269-2-1
Fuse Dimension 10 x 38 mm (Diameter x Length)
Mounting Requires compatible fuse holder for 10x38mm fuses
Utilization Category gG - Full-range breaking capacity for general applications
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PLHT Series
Model Number PLHT-B100
Fuse Standard & Rating IEC gG (General Application)
Rated Current: 100 A
Fuse System NH (Neozed) Style Size B
Rated Voltage 500V AC (690V AC also available - check specific catalog)
Breaking Capacity 50 kA / 100 kA (Depending on specific type and certification)
Standards Compliance IEC 60269-1, IEC 60269-2-1
Contact Type Knife-blade contacts for secure connection in fuse bases
Indicator Visual blown indicator (standard in PLHT series)
Mounting Requires compatible NH fuse base size B
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-C16/4
Fuse Class & Rating Class CC
Rated Current: 16 A
Rated Voltage: 600V AC
Number of Poles / Quantity 4 pieces (4-pole set for 3-phase + Neutral applications)
Type Fast-Acting (Non-Time-Delay)
Rated Voltage 600V AC / 300V DC
Rated Breaking Capacity 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4
Electrical Characteristics Current-Limiting: Yes
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting Requires compatible Class CC fuse holder or fuse block
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZM3-XR
Number of Poles 3-Pole
Mounting Type Draw-Out Version (Fixed mounting in draw-out frame)
Rated Ultimate Breaking Capacity (Icu) Up to 100 kA (Depending on specific current rating and voltage)
Rated Service Breaking Capacity (Ics) Typically 100% of Icu
Rated Operational Voltage (Ue) Up to 690V AC
Rated Insulation Voltage (Ui) 1000V AC
Rated Impulse Withstand Voltage (Uimp) 12 kV
Frame Size Varies (e.g., NZM3-XR available in multiple frame sizes: 400A, 630A, etc.)
Trip Unit Options Available with Thermal-Magnetic (TMD) or Electronic (AE/ME) trip units
Standard Compliance IEC/EN 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, LZMC Series
Model Number LZMC3-A400
Number of Poles 3-Pole
Rated Current 400 A (Frame Size)
Rated Operational Voltage (Ue) Up to 690V AC
Breaking Capacity High interrupting capacity (Specific kA rating depends on voltage - typically 35-65kA range)
Trip Unit Type Type A - Adjustable Electronic Trip Unit
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PN Series
Model Number PN3-400
Number of Poles 3-Pole
Rated Current 400 A
Rated Operational Voltage (Ue) Up to 690V AC
Breaking Capacity (Icu) 50 kA at 415V AC (Typical - confirm with specific catalog)
Trip Unit Type Thermal-Magnetic (Fixed characteristics)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZMH4-AE1250
Number of Poles 4-Pole
Rated Current 1250 A (Frame Size)
Rated Operational Voltage (Ue) Up to 690V AC
Rated Ultimate Breaking Capacity (Icu) Typically 65 kA / 85 kA at 415V AC (Confirm with specific datasheet)
Trip Unit Type AE - Advanced Electronic Trip Unit with LCD Display
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
G - Ground-Fault (Earth Leakage)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, E-Frame Series
Model Number E125E
Rated Current 125 A (Frame Size)
Pole Configurations Available in 1, 2, and 3-pole versions (specific model varies)
Rated Voltage 120/240V AC for 1-2 poles
240V AC for 3 poles
Interrupting Rating 10 kA / 14 kA / 22 kA (Depending on specific version and certification)
Trip Characteristics Thermal-Magnetic
• Thermal Trip: Inverse time delay for overloads
• Magnetic Trip: Instantaneous for short-circuits
Standards Compliance UL 489, CSA C22.2 No. 5
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZMN2-A125
Number of Poles 2-Pole
Rated Current 125 A (Frame Size)
Rated Operational Voltage (Ue) Up to 480V AC
Rated Insulation Voltage (Ui) 690V AC
Rated Ultimate Breaking Capacity (Icu) Typically 25 kA / 35 kA at 480V AC (Confirm with specific datasheet)
Trip Unit Type Type A - Adjustable Electronic Trip Unit
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
Standards Compliance IEC 60947-2