Parameters
Parameter Specification Explanation
Manufacturer & Line Eaton RV Series A standard range of MCBs from Eaton's Moeller series.
Number of Poles 3 3-Pole. Designed to protect a three-phase electrical circuit.
Rated Breaking Capacity 10 kA Can safely interrupt electrical faults up to 10,000 Amperes.
Tripping Characteristic Type C The "S" in the code typically denotes a standard characteristic, which for a 36A MCB is Type C. Suitable for circuits with moderate inrush currents (e.g., lighting, sockets, small motors).
Auxiliary Contacts None The "0" indicates no auxiliary switches (e.g., alarm contact or shunt trip) are fitted.
Rated Current (In) 36 A The maximum continuous current the breaker can carry without tripping under normal conditions.
Key Parameters
Item Specification / Description
Valve Type Electro-proportional flow control cartridge valve (poppet type)
Style / Orientation B style — side-in, nose-out
Function (de-energized) Port-to-port flow blocked (normally closed)
Function (energized) Flow allowed, rate proportional to coil current
Cartridge / Cavity NG16, cavity C-16-3S
Maximum Working Pressure 280 bar
Rated Flow Capacity 0–160 L/min
Operating Fluid Anti-wear hydraulic oils; standard Buna-N seals, Viton optional
Fluid Viscosity Range 10–800 cSt
Operating Temperature Range –30 °C to +90 °C
Internal Leakage (max) ≤ 10 cm³/min at 140 bar
Coil Supply Voltage 24 V DC
Coil Current for Max Flow ~0.7 A @ 24 V DC
Recommended Filtration 15/13/11 (high pressure) or 17/15/12 (lower pressure)
Key Parameters
Item Specification / Description
Valve Type Proportional pressure-compensated flow control cartridge valve
Series / Size DGMPC‑3 (NG6 / CETOP 3 / ISO 4401-03 interface)
Function Controls flow proportionally based on electrical input; maintains stable flow under varying load pressure
Maximum Flow 40 L/min (approx.)
Maximum Operating Pressure 350 bar (≈ 5000 psi)
Pilot Pressure Requirement 20–30 bar typical (for spool operation)
Control Signal 0–10 V DC or 4–20 mA (depending on coil/driver)
Spool Type ABK (proportional spool)
Seal Material Buna-N standard; Viton optional
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Recommended Filtration 17/15/12 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Screw-in cartridge, manifold / subplate mount
Electrical Connector Typically 7-pin connector (depends on variant)
Key Parameters
Parameter Specification / Description
Valve Type Solenoid-operated directional control valve (5/3-way)
Series / Size DG4V-5M (subplate / modular mount)
Spool Type / Center 2AJ spool, closed center
Maximum Operating Pressure 350 bar (≈ 5000 psi)
Maximum Flow Rate 160 L/min (≈ 42 US gpm)
Coil Type / Voltage KUP5 solenoid, 24 V DC standard
Electrical Connection 7-pin DIN connector (variant dependent)
Seal Material H7 (Buna-N standard, compatible with mineral oil)
Metering Function Meter-in or meter-out, depending on spool configuration
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Fluid Cleanliness Recommended 17/15/12 µm (or better)
Operating Temperature –20 °C to +70 °C
Mounting Subplate / manifold mount (ISO 4401 / CETOP 5)
Key Parameters
Parameter Specification / Description
Valve Type Proportional flow control cartridge valve
Series / Size DGMC‑3 (NG6 / CETOP 3 / ISO 4401-03)
Function Regulates flow proportionally based on electrical input; maintains consistent flow under varying load pressure
Maximum Flow 40 L/min (approx.)
Maximum Operating Pressure 350 bar (≈ 5000 psi)
Pilot Pressure Requirement 20–30 bar typical (for spool operation)
Electrical Control Signal 0–10 V DC or 4–20 mA (depending on coil/driver)
Spool Type BT spool (proportional)
Seal Material Buna-N standard; Viton optional
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Recommended Filtration 17/15/12 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Screw-in cartridge, manifold / subplate mount
Electrical Connector Typically 7-pin connector (variant dependent)
Key Parameters
Parameter Specification / Description
Valve Type Solenoid-operated directional control valve, 2-way, 2-position
Series SBV series
Function (de-energized) Normally closed — blocks flow
Function (energized) Opens to allow flow
Rated Flow 12 L/min (approx.)
Maximum Operating Pressure 210 bar (≈ 3000 psi)
Coil Voltage 24 V DC
Electrical Connector DIN 43650-A / ISO 4400 standard connector
Seal Material Buna-N (standard)
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Fluid Cleanliness Recommended 18/16/13 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Subplate / manifold mount
Port Size 1/4″ (or corresponding NG1 / CETOP 1 interface)
Key Parameters
Parameter Specification / Description
Valve Type Solenoid-operated directional control valve, 2-way, 2-position
Series SBV series
Function (de-energized) Normally open — allows flow
Function (energized) Closes to block flow
Rated Flow 12 L/min (approx.)
Maximum Operating Pressure 210 bar (≈ 3000 psi)
Coil Voltage 24 V DC
Electrical Connector DIN 43650-A / ISO 4400 standard connector
Seal Material Buna-N (standard)
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Fluid Cleanliness Recommended 18/16/13 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Subplate / manifold mount
Port Size 1/4″ (or corresponding NG1 / CETOP 1 interface)
Key Parameters
Parameter Specification / Description
Valve Type Proportional flow control cartridge valve
Series / Size DGMX2‑3 (NG6 / CETOP 3 / ISO 4401-03 interface)
Function Regulates flow proportionally based on electrical input; maintains stable flow under varying load pressure
Maximum Flow 40 L/min (approx.)
Maximum Operating Pressure 350 bar (≈ 5000 psi)
Pilot Pressure Requirement 20–30 bar typical (for spool operation)
Electrical Control Signal 0–10 V DC or 4–20 mA (depending on coil/driver)
Spool Type PB (proportional)
Seal Material Buna-N standard; Viton optional
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Recommended Filtration 17/15/12 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Screw-in cartridge, manifold / subplate mount
Electrical Connector Typically 7-pin connector (variant dependent)
Parameters
Parameter Category Specification
Product Type Variable Frequency Drive (VFD) / AC Drive
Brand / Series Eaton DG1 Series
Model Code DG17S4-018N50
Rated Output Power 18.5 kW (25 HP)
Rated Output Current 38 A (at 400V) - Consult datasheet for full range
Input Voltage 3-phase, 380 - 480 V AC, 50/60 Hz
Output Voltage 0 to Input Voltage, 3-phase
Frame Size 7S4
Control Method Sensorless Vector Control & V/Hz Control
Key Features Built-in PID controller, PLC functionality, multiple digital & analog I/O, DC bus choke, keypad with display.
Protection Features Overcurrent, Overvoltage, Undervoltage, Motor Overload, Short Circuit, Ground Fault, Heatsink Overtemperature.
Communication Protocols Modbus RTU, BACnet MS/TP (on board). Optional cards for DeviceNet, PROFIBUS, EtherNet/IP.
Typical Applications Pumps, Fans, Compressors, Conveyors, Mixers.