Industrial Grade Semiconductor Part MVAJ051RA0800B

Alstom / Areva MVAJ051RA0800B high-speed mechanical tripping auxiliary relay from classic MVAJ Midos series, case Size 2 cabinet mounted unit, DC 110V control coil variant (code RA0800B). Designed for fast trip circuit driving, breaker auxiliary interlock, fault signal latching and protection logic expansion in medium voltage switchgear, traction substations, power plant control panels and industrial distribution systems.

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Specifications Basic Identification Brand: Alstom / Areva T&D (GE Grid legacy) Full Model Code: MVAJ051RA0800B Series: MVAJ Midos Auxiliary Tripping Relay Case Size: Size 2 standard cabinet enclosure Core Function: High-speed tripping, fault latching, multi-channel auxiliary signal conversion Coil Rated Voltage: DC 110V Application: MV switchgear bay control, railway traction substation, generator protection panel, transformer trip interlock circuit Coil Electrical Parameters Rated Control Supply Voltage: 110 VDC Operating Voltage Tolerance: 77 ~ 137.5 VDC Coil Power Consumption: ≤10 W at rated voltage Pull-in Voltage: ≤70% Un; Drop-out Voltage: ≥10% Un Operating Response Time: Ultra-fast trip action ≤10 ms Continuous withstand voltage: 125 VDC long-term safe operation Contact Configuration & Load Ratings Contact Arrangement: 5 change-over (CO) multi-contact sets (5NO + 5NC) Continuous thermal carrying current per contact: 5 A AC Breaking Capacity (AC-15, 250 VAC): Max 1250 VA (5A inductive load) DC Breaking Capacity (DC-13, L/R=0.04s, 110 VDC): Max 330 W, 3A inductive trip coil load Momentary make/carry capacity (0.2s short pulse): 30 A peak Contact Material: Silver alloy anti-welding contact tips Mechanical Service Life: ≥10,000,000 cycles (unloaded) Electrical Service Life: ≥100,000 cycles under full rated breaking load Indication & Reset Features Latched mechanical trip flag: Visual red fault indicator, remains locked after trip until manual reset Front panel built-in manual reset push button for fault flag clearing Lockable transparent polycarbonate dustproof front cover, prevents accidental internal contact adjustment Rear screw-clamp terminal block for coil power, trip circuit and signal wiring Mechanical & Installation Mounting Type: Standard flush panel mounting (Size 2 unified cabinet cutout dimension) Overall External Dimensions: H 180 mm × W 144 mm × D 212 mm Net Unit Weight: ~1.6 kg Enclosure: Sealed industrial polycarbonate housing, dust & moisture resistant Environmental & Compliance Standards Operating Ambient Temperature: -20 ℃ ~ +70 ℃ Storage & Transport Temperature: -40 ℃ ~ +85 ℃ Relative Humidity: 5% ~ 95% non-condensing Vibration & Shock Resistance: IEC 60255-21-1 substation anti-vibration test standard EMC Immunity Standard: IEC 61000-6-2 industrial electromagnetic compatibility Compliance Norm: IEC 60255 Measuring relays and protection equipment Certifications: CE marked, RoHS & REACH hazardous substance compliant