Products
Products
home
Industrial Grade Communication Module ACT20X-2SDL-2HDO-S

The Weidmüller ACT20X-2SDI-2HDO-S is a 2-channel intrinsically safe isolating converter designed to control pneumatic or hydraulic valves, solenoids, and alarm transmitters located in hazardous areas (Ex zone 0, 1, 2). It receives switching signals (NPN or PNP) from the safe area and provides a digital, intrinsically safe output to the field in Ex zone 0.

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Specifications Parameter Category Specification Ordering & General Data Order Number 8965420000 Type ACT20X-2SDI-2HDO-S Version EX signal isolating converter, Safe-input: relay, Ex-output: Opto module, 2-channel GTIN (EAN) 4032248785032 Quantity 1 pc(s) Dimensions & Weight Width 22.5 mm / 0.886 inch Height 119.2 mm / 4.693 inch Depth 113.6 mm / 4.472 inch Net Weight 180 g Input (Safe Area) Number of Inputs 2 Input Type NPN, PNP transistor, switching signal Input Voltage ≤ 28 V DC Trigger Level Low ≤ 2.0 V DC (NPN), ≤ 8.0 V DC (PNP) Trigger Level High ≥ 4.0 V DC (NPN), ≥ 10.0 V DC (PNP) Input Resistance, Voltage 3.5 kΩ Output (Ex / Intrinsically Safe) Number of Outputs, Ex 2 Output Type Intrinsically safe circuit, digital, output = input (direct or inverse configurable) Output Current max. 35 mA Output Values (Configurable) 12.5 V @ 35 mA / 13.5 V @ 35 mA / 14.5 V @ 35 mA Residual Ripple (current loop) < 40 mVeff Alarm Output Number of Alarm Outputs 1 Type Status relay, 1 NC (voltage-free) Alarm Functions No supply voltage, Device error Nominal Switching Voltage ≤ 125 V AC / 110 V DC (safe area), ≤ 32 V AC / 32 V DC (zone 2) Continuous Current ≤ 0.5 A AC / 0.3 A DC (safe area), ≤ 0.5 A AC / 1 A DC (zone 2) Power Rating ≤ 62.5 VA / 32 W (safe area), ≤ 16 VA / 32 W (zone 2) General Specifications Supply Voltage 19.2…31.2 V DC Power Consumption ≤ 3.1 W Step Response Time 10 ms Connection Type Screw connection Wire Gauge (AWG) AWG 26...12 Protection Degree IP20 Configuration With FDT/DTM software (requires CBX200 USB adapter 8978580000) Environment Operating Temperature -20 °C...60 °C Storage Temperature -20 °C...85 °C Humidity 0...95 % (no condensation) Safety & Approvals Safety Integrity Level (SIL) SIL 2 (per IEC 61508) MTBF 176 years ATEX/IECEx Marking II (1) G [Ex ia Ga] IIC/IIB/IIA; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I Installation Location Device installed in safe area, zone 2 Ex Parameters (U0/I0/P0) 28 V DC / ≤ 110 mA / ≤ 0.95 W Insulation Voltage 2.6 kV (input / output) Certificates cULus (E337701), ATEX, IECEx, DNV GL