High Precision Industrial Control Module ACT20X-HAI-SA0-S

The Weidmüller ACT20X-HAI-SAO-S (Order No. 8965430000) is a HART®-protocol transparent current supply isolator from the ACT20X series. It is designed to transmit standard 4...20 mA analog DC current signals from hazardous areas (Ex Zone 0, 1, 2) to the safe area with full galvanic isolation.

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Specifications Parameter Category Specification Ordering & General Data Order Number 8965430000 Type ACT20X-HAI-SAO-S Version EX signal isolating converter, HART®, 1-channel, Ex-input: 4 - 20 mA, Safe-output: 4-20mA GTIN (EAN) 4032248785049 Quantity 1 pc(s) Dimensions & Weight Width 22.5 mm / 0.886 inch Height 119.2 mm / 4.693 inch Depth 113.6 mm / 4.472 inch Net Weight 186 g Input (Ex / Intrinsically Safe) Number of Inputs 1 Input Type 4…20 mA (active as current source or passive as current sink) Sensor Supply > 16 V DC Voltage Drop (powered) < 4.5 V Voltage Drop (not powered) < 6 V Residual Ripple < 7.5 mVeff Output Signal in Case of Wire Break < 1 mA Output Number of Outputs 1 Output Signal 4...20 mA (active as current source or passive as current sink) Load Impedance (Current) ≤ 600 Ω Output Signal Limit < 28 mA Load Stability ≤ 0.01 % of end value / 100 Ω Status Output (Alarm) Type Status relay, 1 NC (voltage-free) Alarm Functions Signal limit exceeded, line interruption, no supply voltage, device error Nominal Switching Voltage (Safe Area) ≤ 125 V AC / 110 V DC Nominal Switching Voltage (Zone 2) ≤ 32 V AC / 32 V DC Continuous Current (Safe Area) ≤ 0.5 A AC / 0.3 A DC Continuous Current (Zone 2) ≤ 0.5 A AC / 1 A DC General Specifications Supply Voltage 19.2…31.2 V DC Power Consumption ≤ 1.0 W HART® Transparency Supported (signal forwarded unchanged) Step Response Time ≤ 5 ms Accuracy < 0.1% of span Temperature Coefficient < 0.01% of span/°C Connection Type Screw connection (0.25...2.5 mm² / AWG 26...12) Configuration Via FDT/DTM software (requires CBX200 USB adapter 8978580000) Protection Degree IP20 Environment Operating Temperature -20 °C...60 °C Storage Temperature -20 °C...85 °C Humidity 0...95 % (no condensation) Safety & Approvals Safety Integrity Level (SIL) SIL 2 (per IEC 61508) MTBF 177 a ATEX/IECEx Marking II (1) G [Ex ia Ga] IIC/IIB/IIA; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I Installation Location Device installed in safe area, Zone 2 Ex Parameters (U0/I0/P0) 28 V DC / 93 mA / 0.65 W Insulation Voltage 2.6 kV (input / output) Certificates cULus (E337701), ATEX, IECEx, DNV GL