Specifications
Rated Input Voltage: 1-phase / 3-phase 115~230 VAC, 50/60Hz, ±10% voltage tolerance
Auxiliary Control Power: External isolated 24 VDC
Continuous Output Current: 6 A (RMS per phase)
Peak Output Current: 12 A (RMS), 200% overload sustainable for max 5 seconds
Rated Power Capacity: 12 kVA
DC Bus Voltage Range: 160~320 VDC, shared DC bus for up to 7 slave-axis expansion
PWM Switching Frequency: Configurable 8kHz / 16kHz
Communication Interface: Onboard CANopen fieldbus, maximum baud rate 500 kbps
Optional Configuration: Front LCD status display, 1MB extended flash memory
Control Modes: CANopen bus synchronous control, ±10V analog command, pulse & direction, electronic gearing synchronization
Protection Functions: Soft start, overcurrent, overvoltage, undervoltage, phase loss, short-circuit, overtemperature, motor thermal monitoring, encoder fault multi-level safety protection
Core Features: Local display for fault & status check, 1MB large memory for motion program storage, integrated EMC filter, incremental/SSI encoder emulation output, automatic motor parameter identification and loop auto-tuning
Communication & Feedback Configuration
Onboard Fieldbus: CANopen
Debug Interface: RS232 serial port for parameter configuration, online debugging, firmware upgrade and fault diagnosis
Digital & Analog I/O: 4 programmable isolated digital inputs, 2 programmable isolated digital outputs, 1 analog input terminal
Supported Feedback Types: Resolver, TTL incremental encoder, 1Vpp sine/cosine encoder, Hiperface, EnDat absolute encoder
Encoder Function: Supports incremental encoder simulation output and SSI absolute encoder signal transmission
Mechanical & Environmental Specifications
Protection Class: IP20 (Install vertically on standard DIN rail inside control cabinet)
Mounting Method: DIN rail modular installation, can be cascaded side by side with S400 master servo drives
Operating Ambient Temperature: 0 ℃ ~ +45 ℃; derate power when ambient temperature exceeds 40℃
Storage & Transportation Temperature: -20 ℃ ~ +70 ℃
Ambient Humidity: 5%~95% RH, non-condensing, free of corrosive gas and conductive dust
Altitude Derating: Derate 5% for every 1000m elevation above 1000m
Certifications: CE, UL safety certification