The Omron D4C-1227-P is a Small Enclosed Limit Switch with an adjustable roller lever actuator . It is a general-purpose limit switch featuring a slim design (16 mm width), a triple-sealed construction, and a high protection rating of IP67 against water and dust .

open
TEL:+86 13600179521
Mail:info@easyautomationparts.com
info@easyautomationparts.com
WhatsApp
Parameters
Request a Quote
Return to List
Key Specifications Parameter Specification Product Type Enclosed Limit Switch (Small, General-purpose) Actuator Type Adjustable roller lever (φ17.5 × 7 mm sintered stainless steel roller) Contact Form SPDT (Single Pole Double Throw) Switch Function On-Momentary Contact Rating (AC) 5 A at 250 VAC (resistive load) Contact Rating (DC) 4 A at 30 VDC (resistive load) Connection Method Pre-wired VCTF oil-resistant cable, 3 m length Cable Specifications 4 cores, 0.75 mm² conductor, φ7.6 mm outer diameter Degree of Protection IP67 (IEC 60529) - Dust tight, Waterproof Housing Material Metal / Plastic Indicator Red LED (lights when not operating), 24 VDC Earth Terminal With earth wire (Class I protection against electric shock) Operating Characteristics Parameter Specification Operating Force (OF) 5.69 N max. (approx. 569 gf) Release Force (RF) 1.47 N min. (approx. 150 gf) Pre-Travel (PT) 25° max. Over-Travel (OT) 40° min. Movement Differential (MD) 3° max. Total Travel (TT) 65° Lever Length (R) 30 to 75 mm (adjustable) Permissible Operating Speed — Permissible Operating Frequency Electrical: 30 operations/min max.; Mechanical: 120 operations/min max. Durability & Environmental Ratings Parameter Specification Electrical Durability 200,000 operations min. (at 5 A 125 VAC resistive load) Mechanical Durability 500,000 to 10,000,000 operations min. Ambient Temperature (Operating) -10 to 70 °C (with no icing) Ambient Humidity (Operating) 35% to 95% Insulation Resistance 100 MΩ min. (at 500 VDC) Dielectric Strength Between terminals: 1,000 VAC for 1 min; Between terminal and ground: 1,500 VAC for 1 min Impulse Withstand Voltage 2.5 kV (between live metallic part and ground) Vibration Resistance (Malfunction) 10 to 55 Hz, 1.5 mm double amplitude Shock Resistance (Destruction) 1,000 m/s² max. Shock Resistance (Malfunction) 500 m/s² max. Contact Resistance (Initial) 300 mΩ max. Physical Characteristics Parameter Specification Body Dimensions (W × H × D) 40 mm × 17.4 mm × 65 mm Body Width 16 mm (slim type) Roller Diameter φ17.5 mm Mounting Type Front mounting / Chassis mount Mounting Hole Spacing 25 mm Cable Length 3 meters Weight Approx. 350 g Approved Standards EN, UL, CSA, CCC