W40159X0022
Technical Parameters Parameter Specification Model / Assembly DVC2000 (Assembly: W40159X0022) Input Signal 4-20 mA DC, with HART 5/7 protocol Supply Air Pressure 20 to 150 psi (1.4 to 10.3 bar) - Actuator Dependent Air Consumption (Quiescent) Typically < 0.2 SCFM (0.34 Nm³/hr) Enclosure Rating NEMA 4X (IP66) Ambient Temperature Range -40° to 185°F (-40° to 85°C) Travel Range Actuator Dependent. This is a critical parameter defined by the specific actuator in the assembly. Valve Shutoff Rating Valve Dependent. Defined by the specific valve body included in the assembly. Mounting Directly on linear or rotary actuators (Pre-assembled unit)

More details >> Request a Quote >>
___FISHER
Fisher RS232
Typical Technical Parameters Parameter Specification Interface Type EIA/TIA-232 (Standard Serial RS-232) Connector Type Varies by device. Often a proprietary, weather-proof jack requiring a specific Fisher/Emerson cable (e.g., for connection to a Fisher 475 Field Communicator). Data Format Asynchronous, 8 data bits, No parity, 1 stop bit (8N1) is common. Baud Rate Device-specific, but commonly 9600 or 19200 baud. Communication Mode Full-Duplex, Point-to-Point. Communication Protocol Not a process protocol like HART. It uses a device-specific proprietary protocol (e.g., Fisher's own protocol for the FIELDVUE series) that is interpreted by dedicated configuration tools. Primary Use Local device configuration and diagnostics, not for real-time process control. Compatible Tools Fisher 475 Field Communicator, laptop with AMS Device Manager and a specific interface cable.

More details >> Request a Quote >>
___FISHER
W30382X0012
Technical Parameters Parameter Specification Model / Assembly DVC6200 (W30382X0012) Input Signal 4-20 mA DC, with HART 5/7/ protocol Supply Air Pressure 20 to 150 psi (1.4 to 10.3 bar) - Actuator Dependent Air Consumption (Quiescent) Typically < 0.14 SCFM (0.23 Nm³/hr) Enclosure Rating NEMA 4X / IP66/67 Ambient Temperature Range -40° to 185°F (-40° to 85°C) Travel Range Actuator Dependent. This is a critical parameter defined by the specific actuator in the assembly. Line Size / Valve Type Actuator and Valve Dependent. Defined by the complete assembly. Mounting Directly on linear or rotary actuators (Pre-assembled unit)

More details >> Request a Quote >>
___FISHER
W30382X0032
Typical Specifications Parameter Specification Model DVC6200fp (Assembly: W30382X0032) Communication Protocol Foundation Fieldbus H1 (31.25 kbit/s) with Fisher Proprietary (fp) interface Supply Air Pressure Dependent on the actuator; typically 20 to 150 psi (1.4 to 10.3 bar) Air Consumption Very low quiescent flow; consumption depends on output and stroking Enclosure Rating NEMA 4X (IP66/67) Ambient Temperature -40° to 185°F (-40° to 85°C) Travel Range Dependent on the specific actuator in the assembly. This is a critical parameter that must be confirmed by the detailed product specification sheet. Input Signal Foundation Fieldbus digital signal (via the network) Mounting Directly on linear or rotary actuators (Pre-assembled unit)

More details >> Request a Quote >>
___FISHER
W40159X0012
Typical Specifications Parameter Specification Model DVC2000 (Assembly: W40159X0012) Signal 4-20 mA analog with HART® 5/7 protocol Supply Air Pressure 20 to 150 psi (1.4 to 10.3 bar) - Dependent on actuator capability Air Consumption Low quiescent flow; < 0.2 SCFM (5.7 NLPM) Enclosure Rating NEMA 4X (IP66) Ambient Temperature -40° to 185°F (-40° to 85°C) Travel Range Dependent on the specific actuator in the assembly. Must be confirmed by datasheet. Input Signal 4-20 mA DC, with HART communication Mounting Directly on linear or rotary actuators (Pre-assembled unit)

More details >> Request a Quote >>
___FISHER
TYPE107
Typical Specifications Parameter/Condition Specification Model Type 107 (Size 1 and Size 2 are the most common) Orifice Size Size 1: 1/4 inch (6.4 mm) Size 2: 3/8 inch (9.5 mm) Inlet Supply Pressure Up to 250 psig (17.2 bar) Outlet Pressure Range 5 to 150 psig (0.3 to 10.3 bar) [Adjustable by spring] Maximum Flow Coefficient (Cv) Size 1: ~ 1.0 Size 2: ~ 2.5 Body Material Aluminum (Standard), Ductile Iron (Optional) Connection Sizes 1/4" NPT (Size 1) / 3/8" NPT (Size 2) and 1/2" NPT (for some versions) Temperature Limits Standard Buna-N Elastomer: -20° to 200°F (-29° to 93°C) Optional Viton Elastomer: -20° to 300°F (-29° to 149°C) Approvals Typically meets API 6D requirements.

More details >> Request a Quote >>
___FISHER
W30381X0022
Typical Specifications Parameter Specification Model DVC6200fp (Assembly: W30381X0022) Communication Protocol Foundation Fieldbus H1 (31.25 kbit/s) with Fisher Proprietary (fp) interface Supply Air Pressure Dependent on the actuator; typically 20 to 150 psi (1.4 to 10.3 bar) Air Consumption Very low quiescent flow; consumption depends on output and stroking Enclosure Rating NEMA 4X (IP66/67) Ambient Temperature -40° to 185°F (-40° to 85°C) Travel Range Dependent on the specific actuator in the assembly. This must be confirmed by the detailed datasheet. Input Signal Foundation Fieldbus digital signal (via the network) Mounting Directly on linear or rotary actuators (Pre-assembled unit)

More details >> Request a Quote >>
___FISHER
W30398X0012
Typical Specifications Parameter Specification Model DVC6200 (Assembly: W30398X0012) Signal 4-20 mA analog with HART® protocol (Standard) Supply Air Pressure Typically 20 to 150 psi (1.4 to 10.3 bar) Air Consumption Low quiescent consumption; depends on output volume and stroking speed Enclosure Rating NEMA 4X (IP66/67 equivalent) Ambient Temperature -40° to 185°F (-40° to 85°C) Travel Range Varies with actuator; typically up to 100 mm (linear) or 90° (rotary) Mounting Directly on linear or rotary actuators (Part of a pre-assembled unit in this model) Communication HART® 5/7/ FDT/ DTM (via AMS Device Manager or other compatible systems)

More details >> Request a Quote >>
___FISHER
HSR-CDHBLYN
Technical Parameters Category Parameter Specification / Description Actuator Model/Series HSR Type Double-Acting Rack-and-Pinion Air Connection Likely 1/2" NPT or 3/4" NPT Spring Range Not Applicable (Double-acting has no fail-safe spring) Mounting Style According to ISO 5211 or specific Fisher design for gate valves Valve Valve Type Slab-Disk (Through-Conduit) Gate Valve Valve Size Varies (e.g., 2", 3", 4", 6" - specified when ordering) Pressure Class Varies (e.g., ANSI 600, 900, 1500, 2500) End Connection Flanged (RF or RTJ) or Buttweld (specified when ordering) Positioner & Control Positioner Model FIELDVUE DVC6200 Series or similar Communication Protocol FOUNDATION Fieldbus H1 Supply Pressure Typical: 20 - 100 psi (1.4 - 6.9 bar) Diagnostics Full suite of digital diagnostics (travel, pressure, etc.) Performance & Environment Operating Temperature Standard: -20°F to +180°F (-29°C to +82°C) Extended ranges available Explosive Atmosphere Certification Explosion-Proof (e.g., ATEX, IECEx, or cFMus for Class I, Division 1, Groups B, C, D) Enclosure Rating Typically IP66 / IP67 (Dust-tight and protected against water jets/immersion) Materials Aluminum actuator body, epoxy coating. Stainless steel internals. Valve trim materials per application.

More details >> Request a Quote >>
___FISHER
DVC6215
Technical Parameters Category Parameter Specification / Description General Model DVC6215 Description Digital Valve Controller (HART Protocol) Product Family FIELDVUE Input & Control Input Signal 4 to 20 mA DC, two-wire (sourcing) Supply Pressure Minimum: 2.5 psig (0.17 bar) above actuator requirement Maximum: See table below for supply pressure vs. enclosure material. Characterization Linear, Quick-Open, Equal Percentage, and custom user-configurable Performance Sensitivity 0.05% of span Linearity ±0.5% of span (default) Hysteresis Less than 0.2% of span Air Consumption Steady State: ~0.04 SCFM (1.1 NLPM) During Stroking: ~1.5 SCFM (42.5 NLPM) Pneumatic Output Output Capacity Supply Relay: Up to 100 SCFM (2832 NLPM) Exhaust Relay: Up to 40 SCFM (1133 NLPM) Environmental Ambient Temperature Standard: -40°F to 185°F (-40°C to 85°C) Extended: -40°F to 185°F (-40°C to 85°C) with specific seals. Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water jets/immersion. Material & Pressure Aluminum: Max 150 psig (10.3 bar) Stainless Steel: Max 365 psig (25.2 bar) Hazardous Area Certifications FM/CSA: Explosion-proof, Dust-ignition proof, Intrinsically Safe (Class I, II, III, Div. 1 & 2) ATEX/IECEx: Ex db, Ex tb, Ex ia [ia] (Zone 1 & 21) Physical Conduit Openings Two 1/2" NPT conduit openings Pneumatic Connections Supply & Output: 1/4" NPT Gauges: 1/8" NPT Weight Aluminum: Approx. 4.5 kg (10 lbs) Stainless Steel: Approx. 9.1 kg (20 lbs)

More details >> Request a Quote >>