EATON
DILM750/22(RA250)
Key Parameters Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 75 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 37 kW at 400V / 50 Hz. AC-1 (Resistive Load) 45 kW at 400V. Poles Main Circuits 4 Poles (4 NO) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM750 series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This is a built-in resistor-capacitor network that limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability Typically > 3 million mechanical operations; operational life depends on the load category (e.g., AC-3). Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM580/22(RA250)
Key Parameters Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 58 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 30 kW at 400V / 50 Hz. AC-1 (Resistive Load) 40 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM580 series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 1.5 million operations. Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM500/22(RA250)
Key Parameters Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 50 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 25 kW at 400V / 50 Hz. AC-1 (Resistive Load) 35 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (It is crucial to verify the specific voltage from the coil label or datasheet, as other standard voltages like 24V, 110V, and 400V are available for this series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 1.3 million operations. Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM400/22(RA250)
Key Parameters Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 40 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 18.5 kW at 400V / 50 Hz. AC-1 (Resistive Load) 22 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM400 series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 1.3 million operations. Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM300A/22(RA250)
Key Parameters Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Product Generation A Indicates the enhanced "A" version, offering improved electrical endurance. Rated Operational Current (Ie) AC-1 (Resistive Load) 32 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 15 kW at 400V / 50 Hz. AC-1 (Resistive Load) 22 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or official datasheet, as other voltages like 24V, 110V, and 400V are available). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 2 million operations (improved in the "A" version). Mechanical Durability Typically > 15 million operations. Mounting Standard 35 mm DIN rail (EN 60715). Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM250A/22(RA250)
Key Parameters Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Product Generation A Denotes the enhanced "A" version, offering improved electrical endurance. Rated Operational Current (Ie) AC-1 (Resistive Load) 25 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 11 kW at 400V / 50 Hz. AC-1 (Resistive Load) 18.5 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (It is essential to verify the specific voltage from the coil label or official datasheet, as other standard voltages like 24V, 110V, and 400V are available). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network effectively clamps voltage peaks generated when the coil is de-energized, protecting sensitive control devices. Electrical Durability AC-3 (at rated operational current) Typically > 2 million operations (a key improvement in the "A" version). Mechanical Durability Typically > 15 million operations. Mounting Standard 35 mm DIN rail (EN 60715). Connection Cage clamp (spring-loaded) terminals for fast, secure, and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM225A/22(RAC240)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Product Generation A Denotes the enhanced "A" version, offering improved electrical endurance. Rated Operational Current (Ie) AC-1 (Resistive Load) 22 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 7.5 kW at 400V / 50 Hz. AC-1 (Resistive Load) 15 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (It is essential to verify the specific voltage from the coil label or official datasheet, as other standard voltages like 24V, 110V, and 400V are available). Accessory / Option RAC240 Integrated AC Coil Suppression Module. This accessory is optimized for use with AC coils, helping to reduce electrical noise and improve performance in AC control circuits. Electrical Durability AC-3 (at rated operational current) Typically > 2 million operations (a key improvement in the "A" version). Mechanical Durability Typically > 15 million operations. Mounting Standard 35 mm DIN rail (EN 60715). Connection Cage clamp (spring-loaded) terminals for fast, secure, and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM185A/22(RAC240)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Product Generation A Denotes the enhanced "A" version, offering improved electrical endurance. Rated Operational Current (Ie) AC-1 (Resistive Load) 18 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 5.5 kW at 400V / 50 Hz. AC-1 (Resistive Load) 13 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (It is essential to verify the specific voltage from the coil label or official datasheet, as other standard voltages like 24V, 110V, and 400V are available). Accessory / Option RAC240 Integrated AC Coil Suppression Module. This accessory is optimized for use with AC coils, helping to reduce electrical noise and improve performance in AC control circuits. Electrical Durability AC-3 (at rated operational current) Typically > 2 million operations (a key improvement in the "A" version). Mechanical Durability Typically > 15 million operations. Mounting Standard 35 mm DIN rail (EN 60715). Connection Cage clamp (spring-loaded) terminals for fast, secure, and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM650/22 (RA250)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 65 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 37 kW at 400V / 50 Hz. AC-1 (Resistive Load) 45 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM650 series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 1 million operations. Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
EATON
DILM580/22 (RA250)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 58 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 30 kW at 400V / 50 Hz. AC-1 (Resistive Load) 40 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM580 series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 1.5 million operations. Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>