Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 3 A
Number of Poles 2-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 230 V AC (Single-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 6 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 2 A
Number of Poles 2-Pole
Tripping Characteristic C-Curve
Rated Operational Voltage (Uₑ) DC Voltage - Specific maximum DC voltage must be confirmed from device datasheet
Application DC circuits only
Breaking Capacity Rated for DC circuits according to relevant standards
Standards Compliance Relevant DC standards
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 4 A
Number of Poles 2-Pole
Tripping Characteristic C-Curve
Rated Operational Voltage (Uₑ) DC Voltage - Specific maximum DC voltage must be confirmed from device datasheet (e.g., 60V DC, 125V DC)
Application DC circuits only
Breaking Capacity Rated for DC circuits according to relevant standards
Standards Compliance Relevant DC standards
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 10 A
Number of Poles 3-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 6-10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Parameter Specification
Product Line Eaton PLD RCBO Series
Rated Current 6A
Poles 1P + N (2-pole)
Tripping Characteristic C-Curve (5-10×Iₙ)
Residual Current 30mA
Rated Voltage 230V AC
Breaking Capacity Typically 6kA (IEC 60898)
Standards IEC 61009-1
Mounting DIN Rail (35mm)
Key Parameters
Category Description / Value
Product Line Eaton PLD9 (Miniature Circuit Breakers)
Rated Current (Iₙ) 10 A
Number of Poles Typically 1-Pole (other configurations available)
Tripping Characteristic Standard Characteristic (typically C-Curve)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 4 A
Number of Poles 3-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 6-10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 32 A
Number of Poles 3-Pole
Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ)
Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase)
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton E (Residual Current Releases)
Type Residual Current Release (RCD Module)
Compatible Main Device Specific Eaton load breakers (e.g., certain PL, EZ9 series MCBs).
Poles For use with 1-pole (1P) main devices.
Rated Residual Operating Current (IΔn) 30 mA (0.03 A)
Test Function Manual Test Button (as indicated by "ME" suffix)
Mounting Side-mounted onto the compatible load breaker.
Connection Wiring for the current transformer and auxiliary connections.
Key Parameters
Category Description / Value
Product Line Eaton BZM (Explosion-Proof Enclosures)
Type Explosion-Proof Power Distribution & Control Box
Main Switch Rating 320 A
Branch Circuits 8 ways (as indicated by "S08")
Branch Protection Typically fuses or miniature circuit breakers (specific type to be confirmed from datasheet).
Body Material Cast Aluminum
Hazardous Location Classifications Certified for Class I, Division 1, Class II, Division 1, and Class III groups (Exact certification must be verified).
Enclosure Rating NEMA 4X (Weatherproof and Corrosion-Resistant)
Terminal Compartments Separate compartments for power and control wiring.
Window / Cover Typically includes a window for viewing indicators and a bolted cover.