Products
Products
home
EATON
LZMC2 160A
Parameter Specification Manufacturer / Series Eaton (Often part of the Moeller or IZM brand in some markets) Model Number LZMC2 160A (Full catalog number may include suffixes) Product Type Thermal Overload Relay Pole Configuration 2-Pole Rated Operational Current (Ith) 160 A Setting Current Range Adjustable, typically 100 - 160 A (The exact range must be verified from the datasheet) Trip Class Class 10 (Standard for general purpose motors) Ambient Compensation Yes (Standard feature) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 Mounting Snap-on attachment to a compatible contactor (e.g., Eaton DIL series) Auxiliary Contacts Typically 1 NO (Normally Open) + 1 NC (Normally Closed) Reset Mode Manual reset (Automatic reset may be available as an option) Ambient Temperature -25°C to +60°C (with compensation)

More details >> Request a Quote >>
EATON
NZMH1-A80
Parameter Specification Manufacturer / Series Eaton, NZM Series Model Number NZMH1-A80 Product Type Miniature Circuit Breaker (MCB) Pole Configuration 1-Pole Rated Current (In) 80 A Trip Curve Characteristic H Characteristic (High Inrush) Rated Operational Voltage (Ue) 230/400V AC Rated Insulation Voltage (Ui) 500V AC Rated Frequency 50/60 Hz Breaking Capacity (Icu) 10 kA at 230/400V AC (IEC 60898) / 25 kA at 400V AC (IEC 60947-2) * Standards Compliance IEC 60898-1, IEC 60947-2 Mounting Fixed Mounting (on DIN Rail TH35-7.5) Electrical Life 6,000 cycles Mechanical Life 20,000 cycles Ambient Temperature -25°C to +70°C (Derating above 40°C) Torque Specification Typically 2.0 - 2.5 N·m

More details >> Request a Quote >>
EATON
LZMC3-A320
Parameter Specification Manufacturer / Series Eaton (Often part of the Moeller or DIL product line) Model Number LZMC3-A320 Product Type Thermal Overload Relay Pole Configuration 3-Pole Rated Operational Current (Ith) 320 A Setting Current Range Adjustable, typically within a range such as 200 - 320 A (The exact range must be verified from the datasheet) Trip Class Class 10 (Standard for general purpose motors) Ambient Temperature Compensation Yes (Standard in most LZM relays) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 Mounting Snap-on attachment to a compatible contactor (e.g., Eaton DIL series) Auxiliary Contacts Typically at least 1 NO (Normally Open) and 1 NC (Normally Closed) Reset Mode Manual reset (Automatic reset may be available as an option) Ambient Temperature -25°C to +60°C

More details >> Request a Quote >>
EATON
LZMN3-A320
Parameter Specification Manufacturer / Series Eaton (Often part of the Moeller or DIL product line) Model Number LZMN3-A320 Product Type Thermal Overload Relay Pole Configuration 3-Pole Rated Operational Current (Ith) 320 A Setting Current Range Adjustable, typically within a range such as 200 - 320 A (The exact range must be verified from the datasheet) Trip Class Class 10 (Standard for general purpose motors) Ambient Temperature Compensation Yes (Standard in most LZM relays) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 Mounting Snap-on attachment to a compatible contactor (e.g., Eaton DILM series) Auxiliary Contacts Typically at least 1 NO (Normally Open) and 1 NC (Normally Closed) Reset Mode Manual reset (Automatic reset may be available as an option) Ambient Temperature -25°C to +60°C

More details >> Request a Quote >>
EATON
NZMS2-ME220
Parameter Specification Manufacturer / Series Eaton, NZM Series Model Number NZMS2-ME220 Product Type Molded Case Circuit Breaker (MCCB) with Electronic Trip Unit Pole Configuration 2-Pole Rated Current (In) 220 A (The rated current is set via the trip unit) Trip Unit Type Electronic ("M" - Modular) Rated Operational Voltage (Ue) 400/415V AC Rated Insulation Voltage (Ui) 690V AC Adjustable Protections L (Long-Time), S (Short-Time), I (Instantaneous) Breaking Capacity (Icu) Very High (e.g., 70kA, 100kA, or 150kA at 400V AC). Must be verified from the datasheet. Current Limiting Class Class 3 (Very high current-limiting capability, as per IEC 60947-2) Power Supply Self-powered from the current path (No external AUX power required for basic trip function) Mounting Fixed Mounting Standards Compliance IEC 60947-2 Communication Capability Optional communication modules (e.g., for Modbus, Profibus) can typically be added.

More details >> Request a Quote >>
EATON
PXR20 IZMX16H4-V16W
Parameter Specification Manufacturer / Series Eaton, IZMX Series Model Number IZMX16H4-V16W Product Type 1-Pole + N MCB with Integrated RCD (RCBO) Pole Configuration 1P + N Rated Current (In) 16 A Trip Curve C Characteristic (5-10 x In) Rated Voltage 230V AC Residual Current (IΔn) 30 mA RCD Type Type A (Sensitive to both AC and pulsating DC residual currents) Breaking Capacity (Icn) 10 kA (High Performance) Standards Compliance IEC 61009-1, IEC 60898-1

More details >> Request a Quote >>
EATON
NZMB1-A20-NA
Parameter Specification Manufacturer / Series Eaton, NZM Series Model Number NZMB1-A20-NA Product Type Miniature Circuit Breaker (MCB) Pole Configuration 1-Pole Rated Current (In) 20 A Trip Curve Characteristic B Characteristic (General Purpose) Rated Operational Voltage (Ue) 230/400V AC Rated Insulation Voltage (Ui) 500V AC Rated Frequency 50/60 Hz Breaking Capacity (Icu) 10 kA at 230/400V AC (IEC 60898) / 25 kA at 400V AC (IEC 60947-2) * Standards Compliance IEC 60898-1, IEC 60947-2 Mounting Fixed Mounting (on DIN Rail TH35-7.5) Electrical Life 6,000 cycles Mechanical Life 20,000 cycles Ambient Temperature -25°C to +70°C (Derating above 40°C) Torque Specification Typically 2.0 - 2.5 N·m

More details >> Request a Quote >>
EATON
LZMN2-S125
Parameter Specification Manufacturer / Series Eaton (Often part of the Moeller or IZM brand in some markets) Model Number LZMN2-S125 Product Type Thermal Overload Relay Pole Configuration 2-Pole Rated Operational Current (Ith) 125 A Setting Current Range Adjustable, typically 63 - 125 A (The exact range must be verified from the datasheet) Trip Class Class 10 (Standard for general purpose motors) Ambient Compensation Yes (Standard feature) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 Mounting Snap-on attachment to a compatible contactor (e.g., Eaton DIL series) Auxiliary Contacts Typically 1 NO (Normally Open) + 1 NC (Normally Closed) Reset Mode Manual reset (Automatic reset may be available as an option) Ambient Temperature -25°C to +60°C (with compensation)

More details >> Request a Quote >>
EATON
HJD 65k
Parameter Specification Manufacturer / Series Eaton, HJD Series (Current Limiting Fuse) Model Number HJD 65k Product Type Current Limiting Fuse Rated Voltage Typically 600V AC or 690V AC (Must verify from datasheet) Rated Breaking Capacity (Icn) 65 kA (65,000 Amps RMS Symmetrical) Rated Current (In) Various ratings available (e.g., 100A, 200A, 400A, etc.). The "65k" refers to the interrupting rating, not the current rating. The specific amperage rating is a separate value that must be specified (e.g., HJD 200A 65k). Standards Compliance IEC 60269-1, IEC 60269-2 (or UL/ANSI 248-1 for relevant versions) Let-through Current (Ipk) Very low compared to the prospective fault current (Specific values can be found in peak let-through current charts). Let-through Energy (I²t) Very low, providing excellent thermal protection for downstream devices. Mounting / Style Typically a bolt-on or clip-mount design for secure connection in fuse bases or holders.

More details >> Request a Quote >>
EATON
LZM C3-A320A
Parameter Specification Manufacturer / Series Eaton (Often part of the Moeller or DIL product line) Model Number LZM C3-A320A Product Type Thermal Overload Relay Pole Configuration 3-Pole Rated Operational Current (Ith) 320 A Setting Current Range Adjustable, typically within a range such as 200 - 320 A (The exact range must be verified from the datasheet) Trip Class Class 10 (Standard for general purpose motors) Ambient Temperature Compensation Yes (Standard in most LZM relays) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 Mounting Snap-on attachment to a compatible contactor (e.g., Eaton DILM series) Auxiliary Contacts Typically at least 1 NO (Normally Open) and 1 NC (Normally Closed) Reset Mode Manual reset (Automatic reset may be available as an option) Ambient Temperature -25°C to +60°C

More details >> Request a Quote >>