Parameter Specification / Inference
Product Model LSM-11/RLA
Product Line Eaton Limit Switches
Product Type Heavy-Duty Precision Limit Switch
Contact Configuration 1 NO + 1 NC
Actuator Type Rotating Lever Arm, Adjustable (RLA)
Rated Operational Current Typically 10 A @ 600 V AC
Electrical Life > 1 million operations
Mechanical Life > 10 million operations
Enclosure Rating NEMA 4, 4X, 13; IP67
Housing Material Typically Zinc Die Cast
Terminal Type Screw terminals
Standards Compliance UL Listed, cULus, CE
Parameter Specification / Inference
Product Model LS-11
Product Line Eaton Heavy-Duty Limit Switch
Contact Arrangement Typically 1 NO (Normally Open) + 1 NC (Normally Closed) - Single Circuit, Double Break
Contact Operation Maintained Contact
Switch Mechanism Slow Action (Snap-Action)
Rated Operational Current 10 A @ 600 V AC (A common standard for this series)
Electrical Life Typically 1 to 2 million operations (at rated load)
Mechanical Life Typically 10 million operations
Enclosure Rating NEMA 4, 4X, 6P, 13; IP67 (Dust-tight and protected against immersion)
Housing Material Typically Zinc Die Cast
Operating Head Plunger (as a standard configuration). Various other actuator types (e.g., roller lever, cat whisker) are available with different suffixes.
Terminal Type Screw terminals
Conduit Opening Standard ½" NPT
Temperature Range Typically -20°C to +120°C (-4°F to +248°F)
Standards Compliance UL Listed, cULus Listed, CE
Parameter Specification
Product Model MTL5541A
Product Line Eaton MTL5500+ Series Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated 4-20 mA DC signal.
Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher)
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (MUST be verified from datasheet):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, with enhanced diagnostics (inferred from "A" suffix).
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, etc.
Parameter Specification
Product Model MTL7761PAC
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply AC Input (e.g., 100-240V AC, specific range MUST be verified from datasheet).
Connection Plug-in terminal blocks (inferred from "P") for easy wiring and maintenance.
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification
Product Model MTL5561
Product Line Eaton MTL5500+ Series Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher)
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (MUST be verified from datasheet):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, etc.
Parameter Specification
Product Model DG4V-3-8B-LW-V-M-U-H-L-761
Product Line Eaton DG4V Proportional Valves
Valve Type 4-way, 3-position proportional directional valve
Service Rating (Size) 03 (Nominal flow ~10 US gpm / 38 Lpm)
Maximum Operating Pressure Typically 350 bar (5000 psi)
Solenoid Type Wet Pinion Solenoid (LW)
Coil Voltage 12 V DC
Spool Feedback LVDT (H) for precise closed-loop control
Manual Override Yes (U)
Electrical Connector Specific type (M)
Seal Material Buna-N (L)
Technical Parameters
Category Specification
Model DRAQ127-220-R
Product Type HMI + PLC All-in-One Panel PC
Display
Screen Size 7 inches (diagonal)
Resolution 800 x 480 pixels (WVGA)
Touchscreen Projected Capacitive (PCAP) / Multi-touch
Processor (CPU) Intel Atom E3845, Quad-core, 1.6 GHz
Memory (RAM) 4 GB DDR3L (soldered)
Storage 32 GB eMMC (onboard)
Operating System Windows 10 IoT Enterprise (pre-installed)
Power Supply 220V AC (typically 100-240V AC wide range)
Communication Ports
Ethernet 2 x Gigabit Ethernet (10/100/1000 Mbps)
USB 4 x USB 2.0 ports
Serial (COM) 2 x RS-232/422/485 (software-configurable)
Expansion 1 x Mini PCIe slot (for additional modules like Wi-Fi/4G)
PLC Functionality Integrated runtime for Eaton's PLC software (e.g., XSoft-CODESYS)
Protection Rating IP65 (front panel) - Dust-tight and protected against water jets
Operating Temperature Typically -20°C to +60°C (confirm specific rating in official datasheet)
Technical Parameters
Category Specification
Model T5-4-8903/I5-SI
Product Type 4-Quadrant Digital DC Drive
Input Power
Supply Voltage Typically 400V AC, 3-Phase (Confirm based on "4-" prefix and region)
Frequency 50/60 Hz
Output Power
Armature Output 15 HP / 11 kW (This is a common rating for this frame size, e.g., 8903)
DC Armature Voltage Typically 0-500 V DC
Field Supply Typically 0-300 V DC (for motor field excitation)
Control
Control Type Digital, 4-Quadrant (Regenerative)
Speed Regulation Typically < 1% of base speed (with tachometer)
Typically 2-5% of base speed (armature voltage feedback, IR comp)
Interface Digital Keypad with Display
Communication Optional communication modules (e.g., DeviceNet, Profibus, Modbus)
Features
Diagnostics Comprehensive fault logging and status monitoring
Protections Overcurrent, Overvoltage, Undervoltage, Overload, Heatsink Overtemperature, Field Loss, etc.
Programming Via keypad or PC software (e.g., Eaton's Drive Setup Software)
Enclosure Typically supplied as a chassis unit for panel mounting (IP00). Requires an external enclosure for protection.
Technical Parameters
Category Specification
Model MTL5575
Product Type Safety Relay Module / Safety Loop Monitor
Typical Safety Standard IEC 61508, IEC 61511 (SIL 2 capable)
Input Channels Typically one or two Dual-channel inputs (for monitoring E-Stop circuits etc.)
Input Type Dry contacts (volt-free contacts) from safety devices.
Outputs 3 C/O (Changeover) relays - 2 "Auxiliary" and 1 "Safety".
Contact Rating Typically 8 A, 250 V AC / 5 A, 30 V DC (resistive)
Supply Voltage 24 V DC (nominal), with a wide operating range (e.g., 19-32 V DC).
Key Features
Fault Detection Yes. Automatically detects cross faults, earth faults, and loss of supply.
Reset Modes Manual, Automatic, or Monitored reset (selectable).
Status Indication LED indicators for Power, Inputs, and Faults.
Safety Integrity Level Suitable for SIL 2 applications (as per specific safety manual).
Operating Temperature -40°C to +70°C (standard for industrial MTL products).
Mounting Standard 35 mm DIN rail.
Safety Function Upon a valid input signal or detected fault, it de-energizes the safety relay, breaking the circuit to the controlled device.
Technical Parameters
Category Specification
Model MTL5044
Product Type Foundation Fieldbus H1 Power Conditioner & Repeater
Compliance Designed to meet Foundation Fieldbus H1 standards.
Network Topology Supports trunk-and-spur topology.
Primary Function Signal Conditioning, Repeater, and Power Supply for the fieldbus segment.
Signal Repeater Yes. Regenerates the digital signal, extending the network range.
Number of Ports Typically 4 isolated fieldbus ports, allowing it to create a network hub.
Power Supply Requires an external 24V DC power source (input). Provides conditioned power to the fieldbus.
Key Features
Segment Protection Includes short-circuit protection for each output port.
Diagnostics LED status indicators for power, network activity, and faults.
Isolation Provides galvanic isolation between ports and from the power supply.
Typical Use Case Used in conjunction with intrinsic safety barriers (e.g., MTL5043) to build a complete FISCO / Entity approved Fieldbus system in hazardous areas.
Mounting Standard DIN rail mount.
Operating Temperature -40°C to +70°C (standard for industrial MTL products).