Products
Products
home
EATON
SM4-40(40)151-80/40-10-S205
Technical Parameters Parameter Value Notes Nominal Size 40 NG10 (CETOP 05) interface Maximum Flow Rate 80 L/min 21 US gpm Minimum Controlled Flow 1.5 L/min 0.4 US gpm Maximum Operating Pressure 350 bar 5,075 psi Control Signal 0-10V DC or 4-20mA Analog input with digital interface Hysteresis < 1.5% Maximum value Linearity < 2% Maximum deviation Response Time < 30 ms 10-90% step response Repeatability < 0.5% Typical value

More details >> Request a Quote >>
EATON
TP-P48-N-NDI
Parameter Specification Product Model TP-P48-N-NDI Product Type 19-inch Rackmount Patch Panel Total Ports 48 Connector Type 8P8C (RJ45) Shielding Unshielded (UTP) Performance Category Category 6A Compliant Standards TIA/EIA-568-B.2-10 (Cat 6A) Cable Termination 110-Type Insulation Displacement Connectors (IDC) Wire Gauge 22-26 AWG (solid) Bandwidth Up to 500 MHz Supported Applications
  • 10GBASE-T (IEEE 802.3an)
  • NDI (Network Device Interface) High-Bandwidth Video
  • PoE/PoE+ (IEEE 802.3at/af)
  • Gigabit Ethernet (1000BASE-T)
Color Black Mounting Standard 19-inch Rack (1U Height) Key Feature Optimized and tested for superior performance with NDI protocols.

More details >> Request a Quote >>
EATON
XTOE1P6CGSS
Parameter Specification Product Model XTOE1P6CGSS Product Type Duplex Receptacle / Outlet Grade Commercial Spec Grade Current Rating 15 A Voltage Rating 125 VAC Poles & Wires 2-Pole, 3-Wire Receptacle Configuration 5-15R (Two vertical slots and a round ground pin) Tamper Resistance Yes (TR), complies with NEC requirements for safety. Construction Material Stainless Steel body and faceplate Color / Finish Stainless Steel (Brushed Satin look) Wiring Type Side and Back Wire (Pressure Plate Clamp terminals for secure connections) Mounting Standard Wall Mount Compliant Standards UL Listed, cULus Listed, compliant with NEC and OSHA standards. Special Features
  • Corrosion-resistant stainless steel construction.
  • Self-grounding (No separate ground wire needed to the mounting strap).
  • Thermoplastic interior for electrical insulation.
  • Designed for high-traffic and harsh environments.


More details >> Request a Quote >>
EATON
13104RS5007
Parameter Specification Product Model 13104RS5007 Product Line Cutler Hammer by Eaton Product Type Emergency Stop Push Button Station Button Type Mushroom Head, Emergency Stop (E-STOP) Button Function Maintained Contact (latching); requires a twisting or pulling action to release after being pressed. Button Diameter 50 mm (Large, highly visible and accessible) Button Color Red Contact Block Typically supplied as a N.O. (Normally Open) contact that opens when pressed (safety standard). Note: Configuration can vary; verifying the specific contact arrangement upon receipt is recommended. Enclosure Rating NEMA 4X (Weatherproof, Watertight, Dusttight, Corrosion-Resistant) Ingress Protection (IP) IP66 (Equivalent to NEMA 4X, protected against powerful water jets and dust.) Enclosure Material Fiberglass Reinforced Polyester or similar robust, corrosion-resistant material. Mounting Surface Mount Operator Material Thermoplastic or Metal (designed for high impact and repeated use) Applications Industrial machinery, manufacturing lines, processing plants, and any application requiring a highly visible and reliable emergency stop function. Compliant Standards UL Listed, cULus Listed, conforms to relevant IEC and NEMA standards for safety devices.

More details >> Request a Quote >>
EATON
311574
Parameter Specification Product Model 311574 Product Type Window-type, Fixed-mount Current Transformer (CT) Rated Primary Current (Ipr) 400 A Rated Secondary Current (Isr) 5 A Frequency 50/60 Hz Accuracy Class 0.5 or 1.0 Burden (Rated Output) e.g., 2.5 VA or 5 VA Insulation / Voltage Rating e.g., 600 V to 1000 V Window Diameter (Opening) e.g., 30 mm Mounting Method Fixed mounting, typically with pre-drilled holes for bolts/screws. Standards Compliance Complies with IEC 61869-1, IEC 60044-1, or equivalent ANSI/IEEE standards. Applications
  • Electrical energy metering
  • Power monitoring systems
  • Motor load monitoring
  • Protective relaying
Material Typically a thermoset or thermoplastic insulated housing.

More details >> Request a Quote >>
EATON
NZM1/2-XCR-S/MODAN
Parameter Specification Notes / Typical Value for this Series Product Model NZM1/2-XCR-S/MODAN Product Line NZM (Molded Case Circuit Breaker) Rated Operational Voltage (Ue) Typically up to 690V AC Rated Current (In) Depends on the Rating Plug. The frame size NZM1/2 supports a range (e.g., up to 63A or 125A). The actual current is set by a separate rating plug. Rated Ultimate Breaking Capacity (Icu) Standard Breaking Capacity ("S") Specific kA value at a given voltage (e.g., 25kA @ 415V) must be verified from datasheet. Trip Unit Type Electronic (XCR) Protection Functions
  • L - Long-Time (Overload)
  • S - Short-Time (Short-Circuit)
  • I - Instantaneous
  • G - Ground Fault
All thresholds are adjustable. Communication Capability Yes (Typically PROFIBUS-DP or Modbus) The "X" in XCR often denotes communication readiness. Requires a separate communication module. Auxiliary Contacts Can be equipped Via add-on modules. Mounting Fixed or Plug-in (as per MODAN kit) The "MODAN" kit facilitates specific mounting. Standards Compliance IEC 60947-2, UL 489, etc.

More details >> Request a Quote >>
EATON
FAZ-B63/3N
Parameter Specification Product Model FAZ-B63/3N Product Line Eaton FAZ B-Series (Miniature Circuit Breaker) Number of Poles 3 Poles + Neutral (3P+N) Rated Current (In) 63 A Tripping Characteristic B-Curve (Instantaneous tripping between 3 to 5 times rated current). Suitable for resistive and low inductive loads. Rated Operational Voltage (Ue) 230/400 V AC Rated Insulation Voltage (Ui) 500 V AC Rated Impulse Withstanding Voltage (Uimp) 4 kV Rated Breaking Capacity (Icn) Typically 10 kA at 230/400V AC according to IEC 60898-1. (Please confirm with local catalog as higher capacity versions may exist). Standards IEC/EN 60898-1, IEC/EN 60947-2 Terminal Connection Suitable for cables up to 35 mm² (copper). Mounting Standard DIN Rail (35 mm) mounting. Mechanical Life Typically > 20,000 cycles Electrical Life Typically > 10,000 cycles Torque Screw Typically 3.0 N·m

More details >> Request a Quote >>
EATON
LS-11DA
Parameter Specification Product Model LS-11DA Product Type Heavy-Duty Limit Switch Contact Arrangement 1 NO (Normally Open) + 1 NC (Normally Closed) - Single Circuit, Double Break Contact Operation Maintained Contact Switch Mechanism Slow Action (Snap-Action) Rated Operational Current Typically 10 A @ 600 V AC / 0.5 A @ 600 V DC (Specific values depend on thermal and inductive load) Electrical Life Typically 1 to 2 million operations (at rated load) Mechanical Life Typically 10 million operations Enclosure Rating NEMA 4, 4X, 6P, 13; IP67 (Dust-tight and protected against immersion) Housing Material Typically Zinc Die Cast Operating Head Various actuator types available (e.g., roller lever, plunger) - the "DA" suffix may specify a particular type. Terminal Type Screw terminals Conduit Opening Standard ½" NPT Temperature Range Typically -20°C to +120°C (-4°F to +248°F) Standards Compliance UL Listed, cULus Listed, CE

More details >> Request a Quote >>
EATON
BLR-CX06R
Parameter Specification Product Model BLR-CX06R Sensor Type Inductive Proximity Sensor Body Shape Rectangular Detection Type Shielded (Embeddable) Output Type DC 3-wire Output Configuration NPN Normally Open (NO) Supply Voltage 10 to 30 V DC Rated Sensing Distance 2 mm (±10%) Setpoint 0 to 1.62 mm Hysteresis ≤ 10% of rated sensing distance Standard Target Fe 12x12x1 mm (Mild Steel) Response Frequency 500 Hz Protection Circuit Reverse Polarity Protection, Short-circuit protection, Overcurrent protection Protection Rating IP67 Housing Material Nickel-plated brass Connection Type Pre-wired cable (2m standard length is common, but please verify) Operating Temperature -25 to 70°C Compliance CE

More details >> Request a Quote >>
EATON
MTL-779+
Parameter Specification Product Model MTL-779+ Product Line Eaton MTL Signal Conditioners & Isolators Function 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area. Output Signal 4-20 mA DC (Isolated) Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Typically 20-30 V DC (for standard models) Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (Example values, MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).

More details >> Request a Quote >>
1 2
··· ···