Key Parameters
Parameter Specification / Description
Valve Type Proportional pressure-compensated flow control cartridge valve
Series / Size DGMC2‑3 (NG6 / CETOP 3 / ISO 4401-03 interface)
Function Controls flow proportionally based on electrical input; maintains stable flow under varying load pressure
Maximum Flow 40 L/min (approx.)
Maximum Operating Pressure 350 bar (≈ 5000 psi)
Pilot Pressure Requirement 20–30 bar typical (for spool operation)
Electrical Control Signal 0–10 V DC or 4–20 mA (depending on coil/driver)
Spool Type AT / BT (proportional pilot-operated)
Seal Material Buna-N standard; Viton optional
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Recommended Filtration 17/15/12 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Screw-in cartridge, manifold / subplate mount
Electrical Connector Typically 7-pin connector (variant dependent)
Key Parameters
Parameter Specification / Description
Valve Type Pilot-operated pressure relief valve
Series / Size ST307‑V2
Function Limits system pressure by opening when preset pressure is exceeded
Maximum Pressure 150 bar (≈ 2175 psi)
Flow Capacity Up to rated flow (depends on system configuration, approx. 50–100 L/min typical)
Adjustment Adjustable spring for setting desired relief pressure
Seal Material Buna-N standard; Viton optional
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Fluid Viscosity Range 10–800 cSt
Operating Temperature –20 °C to +80 °C
Mounting Type Subplate / manifold mount
Port Size NG10 / CETOP 5 (or as per installation requirements)
Key Parameters
Parameter Specification / Description
Coil Type Solenoid coil for hydraulic valves
Part Number 02‑154423
Rated Voltage 24 V DC
Rated Current 7 A
Duty Cycle Continuous duty
Operating Temperature –20 °C to +70 °C
Electrical Connector Flying leads or DIN connector (variant dependent)
Mounting Screw-in / valve-specific mount
Insulation Class Typically Class H or equivalent
Environmental Protection Designed for industrial/mobile environments (splash and dust resistant)
Compatible Valves Directional control valves, proportional valves (specific series dependent)
Key Parameters
Parameter Specification / Description
Valve Type Proportional directional control cartridge valve
Series / Size DGMDC‑3 (NG6 / CETOP 3 / ISO 4401-03 interface)
Function Controls flow direction proportionally based on electrical input; maintains stable operation under varying load pressure
Maximum Flow 40 L/min (approx.)
Maximum Operating Pressure 350 bar (≈ 5000 psi)
Pilot Pressure Requirement 20–30 bar typical (for spool operation)
Electrical Control Signal 0–10 V DC or 4–20 mA (depending on coil/driver)
Spool Type X / BK (proportional pilot-operated)
Seal Material Buna-N standard; Viton optional
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Recommended Filtration 17/15/12 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Screw-in cartridge, manifold / subplate mount
Electrical Connector Typically 7-pin connector (variant dependent)
Key Parameters
Parameter Specification / Description
Valve Type Pilot-operated pressure relief cartridge valve
Function Protects hydraulic circuits by relieving excess pressure
Maximum Operating Pressure 350 bar (≈ 5000 psi)
Flow Capacity Up to rated flow (depends on system design, typically 20–50 L/min)
Adjustment Adjustable spring for setting desired relief pressure
Seal Material Buna-N standard; Viton optional
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Fluid Viscosity Range 10–800 cSt
Operating Temperature –20 °C to +80 °C
Mounting Type Screw-in cartridge or manifold mount
Port Size NG6 / CETOP 3 (or as per installation requirements)
Key Parameters
Parameter Specification / Description
Valve Type Solenoid-operated directional control valve, 3-position, 4-way
Series DSG-01
Function Controls hydraulic flow direction; closed center in neutral
Maximum Flow Rate 30 L/min (approx.)
Maximum Operating Pressure 210 bar (≈ 3000 psi)
Actuation Solenoid, 24 V DC
Spool Type 3C2 (closed-center, 3-position)
Seal Material NBR/Buna-N standard; Viton optional
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Fluid Cleanliness Recommended 18/16/13 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Subplate mount (ISO 4401 / CETOP 3 interface)
Electrical Connector DIN 43650-A / ISO 4400 standard
Key Parameters
Parameter Specification / Description
Valve Type Solenoid-operated directional control valve, 3-position, 4-way
Series DG4V-3
Function Controls hydraulic flow direction; closed center in neutral
Maximum Flow Rate 60 L/min (approx.)
Maximum Operating Pressure 350 bar (≈ 5000 psi)
Actuation Solenoid, modular type
Spool Type 2AL (closed-center, 3-position)
Seal Material H7 (Buna-N standard, Viton optional)
Fluid Compatibility Mineral-based hydraulic oils, anti-wear oils
Fluid Cleanliness Recommended 17/15/12 µm or better
Operating Temperature –20 °C to +70 °C
Mounting Type Subplate / manifold mount (ISO 4401 / CETOP 3 interface)
Electrical Connector DIN 43650 / ISO 4400 standard
Parameter Specification
Product Series DPS2
Ordering Code / Article No. DPS2-20-S-F0-20
Input
Input Voltage (AC) 100 - 240 V AC (±10%)
Input Frequency 47 - 63 Hz
Input Current 0.9 A at 115V AC; 0.5 A at 230V AC
Inrush Current (I²t) < 20 A²s
Output
Output Voltage 24 V DC
Rated Output Current 0.8 A
Power
Output Power (at 40°C) 20 W
Boost Function
Boost Current 1.2 A (for up to 5 seconds)
Performance & Characteristics
Efficiency Up to 94.5%
Power Factor (λ) >0.65 at 230V AC / >0.5 at 115V AC
Ripple and Noise < 150 mVpp
Line Regulation < ±0.5%
Load Regulation < ±1.0%
Protections
Overload Protection Electronic, self-recovery (Hiccup mode)
Overvoltage Protection 28 - 32 V DC (Clamping type)
Short-Circuit Protection Yes, automatic recovery
Environmental & Physical
Operating Temperature -25 °C to +70 °C (with derating above 40°C)
Storage Temperature -40 °C to +85 °C
Cooling Method Natural convection (fanless)
Housing Material Plastic (Polycarbonate)
Mounting Standard DIN Rail (EN 60715: 35mm)
Dimensions (W x H x D) 22.5 x 90 x 96 mm
Weight Approx. 0.18 kg
Safety & EMC Standards
Safety Standards UL 508, CSA C22.2 No. 14, EN 62368-1 (CB Report)
EMC Standards EN 61000-6-2, EN 61000-6-4
Certifications cULus Listed, CE Marked, RCM Marked
Parameter Specification
Manufacturer / Series Eaton / DG4V-5
Part Number / Model DG4V-5-2AJ-M-U-H6-20
Valve Type Solenoid Operated, Directional Control Valve
Configuration 5-Port, 4-Way (5/4)
Actuation Type Single Solenoid, Spring Offset
Spool Type 2AJ (This is a specific spool configuration. Refer to Eaton's datasheet for exact flow path characteristics).
Mounting Style Subplate Mounting (ISO 4401-05 (CETOP 5) interface)
Electrical Connection DIN 43650 Form A (with LED indicator and manual override)
Coil Voltage (Example) Note: The "-H6-20" typically specifies the coil. H6 often denotes 12V DC. This must be confirmed with the supplier or datasheet as other voltages are available.
Protection Class IP65 (Dust tight and protected against water jets)
Performance
Nominal Flow Rate 20 L/min (5 US GPM)
Maximum Operating Pressure 350 bar (5,000 psi)
Maximum Peak Pressure 400 bar (6,000 psi)
Solenoid Characteristics
Solenoid Type Wet Pin AC or DC (specific to order code)
Duty Cycle Continuous (Class F insulation system)
Hydraulic Fluid Mineral oil-based hydraulic fluids to ISO 11158 (e.g., HV46)
Fluid Temperature Range -30 °C to +80 °C (-22 °F to +176 °F)
Fluid Viscosity Range 10 to 500 cSt (50 SSU to 2300 SSU)
Filtration Level Recommended: 25 µm absolute or better, per ISO 4406 code 18/16/13
Weight (Approx.) ~2.5 kg (5.5 lbs) - (varies with coil and options)
Materials
Housing Steel
Spool Hardened Steel
Seals Nitrile (Buna-N) - Standard
Parameter Specification
Manufacturer / Series Eaton / CV2
Part Number / Model CV2-20-P-0-30
Valve Type Two-Port, Pilot Operated Relief Valve (Screw-in Cartridge)
Cavity Standard ISO 7368 (Size 20)
Thread M45x2
Seal Kit Eaton E-KT-30 (or similar - confirm with latest datasheet)
Function Pressure Control / System Relief
Performance
Nominal Size 20
Adjustable Pressure Range 3 to 30 bar (43 to 435 psi) [Critical Feature]
Maximum Operating Pressure 350 bar (5,000 psi)
Flow Capacity Up to 150 L/min (40 US GPM) - Flow is dependent on pressure setting and pressure drop. Refer to performance curves.
Recommended Flow Range 5 to 150 L/min
Hydraulic Fluid Mineral oil to ISO 11158 (HV46) or similar petroleum-based fluids.
Fluid Temperature Range -20 °C to +80 °C (-4 °F to +176 °F)
Fluid Viscosity Range 10 to 380 cSt (50 to 1800 SSU)
Filtration Level Recommended: 25 µm absolute or better, per ISO 4406 code 19/17/14