Key Parameters
Category Description / Value
Product Line Eaton EASY (Smart Relays)
Series EASY500
Model / CPU EASY512
Power Supply DC (Typical rating: 24 V DC. Must be verified on the device).
Digital Inputs 8
Digital Outputs 4 (Relay Contacts - as indicated by "RC").
Output Type Relay (Electromechanical) - Can switch AC or DC loads within rating.
Programming Via EASY-SOFT software or directly on the device using the built-in display and buttons.
Display Integrated LCD for showing values, status, and messages.
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Communication Optional communication modules (e.g., for Ethernet, AS-Interface, IO-Link) can be added.
Key Parameters
Category Description / Value
Product Line Eaton EASY (Smart Relays)
Series EASY800
Model / CPU EASY820
Power Supply DC (Typical rating: 24 V DC. Must be verified on the device).
Digital Inputs 12
Digital Outputs 8 (Relay Contacts - as indicated by "RC").
Output Type Relay (Electromechanical) - Can switch AC or DC loads within rating.
Programming Via EASY-SOFT software or directly on the device using the built-in display and buttons.
Display Integrated LCD for showing values, status, and messages.
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Communication Optional communication modules (e.g., for Ethernet, AS-Interface, IO-Link) can be added.
Key Parameters
Category Description / Value
Product Line Eaton EASY (Smart Relays)
Series EASY800
Model / CPU EASY819
Power Supply AC (Common ratings: 120V AC or 230V AC. Must be verified on the device).
Digital Inputs 12
Digital Outputs 8 (Relay Contacts - as indicated by "RC").
Output Type Relay (Electromechanical) - Can switch AC or DC loads within rating.
Programming Via EASY-SOFT software or directly on the device using the built-in display and buttons.
Display Integrated LCD for showing values, status, and messages.
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Communication Optional communication modules (e.g., for Ethernet, AS-Interface, IO-Link) can be added.
Key Parameters
Category Description / Value
Product Line Eaton EASY Expansion Modules
Compatible Controllers EASY800 Series Base Units (e.g., EASY819, EASY820)
Module Type Digital I/O Expansion Module
Power Supply AC (Common ratings: 120V AC or 230V AC. Must be verified on the device).
Total I/O Points 16
Digital Inputs 8
Digital Outputs 8 (Relay Contacts)
Output Type Relay (Electromechanical) - Can switch AC or DC loads within rating.
Connection to Base Unit Via a flat ribbon cable (usually included).
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Key Parameters
Category Description / Value
Product Line Eaton NZM4
Model / Frame Size NZM4-XKM2
Release Type Electronic Trip Unit (as indicated by "S") - Adjustable protection settings.
Rated Current (Iₙ) 1250 A (This is the frame rating. The operational current can be set within a range on the electronic trip unit).
Poles 3-Pole & 4-Pole versions are available.
Rated Operational Voltage (Uₑ) Up to 690 V AC, 50/60 Hz
Rated Insulation Voltage (Uᵢ) 1000 V
Rated Ultimate Short-Circuit Breaking Capacity (Iᶜᵘ) Very high, typically 100 kA or more at 400V AC (IEC 60947-2). The exact value must be verified from the technical data sheet.
Trip Unit Functions • Long-time Delay (L)
• Short-time Delay (S)
• Instantaneous (I)
• Ground-fault (G) protection (depending on the specific "S" variant).
Mounting Fixed Mounting (for bolted installation in panels) or Draw-out Version (available as an option).
Connection Primary power connections are typically made via busbars.
Standards Compliance IEC/EN 60947-2
Auxiliary Contacts & Accessories Compatible with the full range of NZM4 accessories, such as auxiliary contacts, undervoltage release, shunt trip, and motor operator.
Key Parameters
Category Description / Value
Product Line Eaton PKZ (Equipment Protectors)
Model / Frame Size PKZMC
Rated Current (Iₙ) 1.6 A (This is the fixed rated current for this specific device).
Poles 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions are available.
Rated Operational Voltage (Uₑ) 400/690 V AC
Tripping Characteristic C-Curve (Moderate inrush current tolerance, typically 5-10 x Iₙ).
Breaking Capacity Typically high, up to 100 kA at 400V AC (IEC 60947-2), thanks to its current-limiting design.
Standards Compliance IEC/EN 60947-2
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Connection Cage Clamp terminal technology for easy, tool-free wiring.
Auxiliary Contacts Available as snap-on modules (e.g., PKZMC-AX) to provide signaling (e.g., trip indication).
Control Function Manual ON/OFF switching with a toggle handle. Can be padlocked in the OFF position.
Key Parameters
Category Description / Value
Product Line Eaton DILM
Model / Frame Size DILM250
Rated Operational Current (Iₑ) at AC-3 250 A (For squirrel-cage motors)
Rated Operational Power at AC-3 ~ 132 kW / 177 HP at 400V 50Hz
Rated Operational Voltage (Uₑ) Up to 1000 V AC, 50/60 Hz
Rated Thermal Current (Iᵼₕ) 300 A
Poles 3 (Main Contacts)
Coil Control Voltage Standard factory setting is often 400V/500V AC. However, this is configurable. The exact voltage must be confirmed by the order code sticker on the device itself.
Utilization Categories AC-3: Squirrel-cage motors
AC-1: Non-inductive loads
Standard Auxiliary Contacts 2 normally open (NO) contacts (as indicated by "/22")
Integrated Adapter RA250 adapter pre-mounted, enabling quick installation of RCU250 modules.
Electrical Durability Hundreds of thousands of operations (load-dependent)
Mechanical Durability Millions of operations
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Mounting Screw mounting via integrated feet or mounting plate.
Connection Large screw terminals for main power connections.
Key Parameters
Category Description / Value
Product Line Eaton DILM
Model / Frame Size DILM225A
Rated Operational Current (Iₑ) at AC-3 225 A (For squirrel-cage motors)
Rated Operational Power at AC-3 ~ 110 kW / 150 HP at 400V 50Hz
Rated Operational Voltage (Uₑ) Up to 1000 V AC, 50/60 Hz
Rated Thermal Current (Iᵼₕ) 300 A
Poles 3 (Main Contacts)
Coil Control Voltage Standard factory setting is often 400V/500V AC. However, this is configurable. The exact voltage must be confirmed by the order code sticker on the device itself.
Utilization Categories AC-3: Squirrel-cage motors
AC-1: Non-inductive loads
Standard Auxiliary Contacts 2 normally open (NO) contacts (as indicated by "/22")
Integrated Adapter RAC440 adapter pre-mounted, enabling quick installation of RCM440 modules.
Electrical Durability Hundreds of thousands of operations (load-dependent)
Mechanical Durability Millions of operations
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Mounting Screw mounting via integrated feet or mounting plate.
Connection Large screw terminals for main power connections.
Key Parameters
Category Description / Value
Product Line Eaton DILM
Model / Frame Size DILM225A
Rated Operational Current (Iₑ) at AC-3 225 A (For squirrel-cage motors)
Rated Operational Power at AC-3 ~ 110 kW / 150 HP at 400V 50Hz
Rated Operational Voltage (Uₑ) Up to 1000 V AC, 50/60 Hz
Rated Thermal Current (Iᵼₕ) 300 A
Poles 3 (Main Contacts)
Coil Control Voltage Standard factory setting is often 400V/500V AC. However, this is configurable. The exact voltage must be confirmed by the order code sticker on the device itself.
Utilization Categories AC-3: Squirrel-cage motors
AC-1: Non-inductive loads
Standard Auxiliary Contacts 2 normally open (NO) contacts (as indicated by "/22")
Integrated Adapter RAC500 adapter pre-mounted, enabling quick installation of RCA/RCM500 modules.
Electrical Durability Hundreds of thousands of operations (load-dependent)
Mechanical Durability Millions of operations
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Mounting Screw mounting via integrated feet or mounting plate.
Connection Large screw terminals for main power connections.
Key Parameters
Category Description / Value
Product Line Eaton DILM
Model / Frame Size DILM225A
Rated Operational Current (Iₑ) at AC-3 225 A (For squirrel-cage motors)
Rated Operational Power at AC-3 ~ 110 kW / 150 HP at 400V 50Hz
Rated Operational Voltage (Uₑ) Up to 1000 V AC, 50/60 Hz
Rated Thermal Current (Iᵼₕ) 300 A
Poles 3 (Main Contacts)
Coil Control Voltage Standard factory setting is often 400V/500V AC. However, this is configurable. The exact voltage must be confirmed by the order code sticker on the device itself.
Utilization Categories AC-3: Squirrel-cage motors
AC-1: Non-inductive loads
Standard Auxiliary Contacts 2 normally open (NO) contacts (as indicated by "/22")
Integrated Adapter RDC240 adapter pre-mounted, enabling quick installation of RCM240 modules.
Electrical Durability Hundreds of thousands of operations (load-dependent)
Mechanical Durability Millions of operations
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Mounting Screw mounting via integrated feet or mounting plate.
Connection Large screw terminals for main power connections.