Technical Specifications
Parameter Specification / Description Notes
Manufacturer / Series Eaton MCM (Modular Control Manifold)
Model Number DGMC-2-3-AB-CW-BA-CW-41
Product Type Integrated Hydraulic Manifold Block
Port Size (P, T) D02 (NG4) The "-2-" likely denotes the primary pressure and tank port size.
Work Port Size (A, B) D03 (NG6) The "-3-" likely denotes the work port (A, B) size for each section.
Number of Sections 2 Identical Work Sections The pattern "-AB-CW-" and "-BA-CW-" confirms two parallel sections.
Internal Cartridge Valves Cavities for CETOP-style cartridges The specific types are defined by the suffix codes.
Maximum Operating Pressure 350 bar (5,000 psi) Typical for this series.
Maximum Flow Rate (Total) ~ 75 L/min (20 US gpm) Shared between the two sections.
Technical Specifications
Parameter Specification / Description Notes
Manufacturer / Division Eaton Aerospace
Model Number ICE30F35S5
Product Type Brushless AC Generator (Alternator)
Output Power 30 kVA (or similar, based on "30" in model number) Kilo-Volt-Ampere, the apparent power rating.
Output Phase 3-Phase Standard for aircraft AC systems.
Output Voltage 115/200 VAC Typical aircraft AC voltage.
Output Frequency 400 Hz Standard frequency for aerospace applications.
Cooling Method Air-cooled or Oil-cooled Common methods for aircraft generators.
Speed Range Designed to operate at a specific constant speed (e.g., 6000 RPM, 8000 RPM) Aircraft generators run at a constant speed.
Mounting Flange mount per aerospace standard
Compliance Meets relevant aerospace standards (e.g., DO-160, MIL-STD)
Technical Specifications
Electrical
Voltage: 24 V DC
Power Rating: approx. 26–29 W
Duty Rating: Continuous duty (operates at 85%–110% of rated voltage)
Mechanical / Environmental
Connector Type: DIN 43650-A (ISO 4400)
Coil Housing: Glass-filled nylon
Ingress Protection: IP65 (dust-tight and water-resistant)
Operating Temperature: Up to 100 °C
Weight: approx. 0.14–0.18 kg
Hydraulic Compatibility
Used with Eaton/Vickers screw-in cartridge valves (Size 10 / 12 / 16 / 20)
Suitable for valves rated up to 350 bar (5075 psi)
Compatible with standard hydraulic fluids (e.g., MIL-H-5606, SAE 10/20)
Design / Mounting
Solenoid coil only (no ports)
Explosion-proof-style construction
Fits standard Eaton cartridge-valve solenoid tubes
Technical Specifications
Valve Type: Pilot-operated, solenoid-controlled directional control valve (two-stage)
Series: DG5S4-04 (subplate / manifold mount; ISO 4401 Size 07)
Actuation / Operation: Pilot operated, solenoid controlled
Coil / Electrical Connection: 24 V DC coil, ISO 4400 (DIN 43650) connector
Mounting Interface: ISO 4401-07 (subplate / manifold mount)
Flow Capacity: Up to 227 L/min (≈ 60 US gpm)
Maximum Operating Pressure: 210 bar (≈ 3000 psi)
Body Material: Gray Iron, solid cast with cored passages
Seal Material: Standard Buna-N (nitrile)
Spool Type / Spool Arrangement: Two-stage spool, spring-centered spool arrangement
Stage: Two-stage directional valve
Fluid Compatibility: Petroleum-based hydraulic oils
Fluid Cleanliness Requirement: 19/17/14 (micron)
Operating Temperature Range: –20 °C to +70 °C (approx. –4°F to +158°F)
Mount Type: Subplate / manifold mount
Manual Override: Plain (no special override)
Tank / Return Port Rating: same as pressure rating (210 bar / 3000 psi)
Pilot Pressure Type: Internal pilot supply
External Features: Standard performance (no special features like explosion-proof, spool monitoring, or damping — unless configured differently)
Technical Specifications
Brand / Series: Vickers by Eaton — DG4V-5 (22 series)
Model Code: DG4V-5-2AJ-M-U-H7-22
Valve Type: 4-way directional control valve (solenoid-operated)
Mounting / Interface: ISO 4401-05 / NFPA D05 / NG10 (subplate / manifold mount)
Actuation: Solenoid, electrical connection via ISO 4400 (DIN 43650) connector
Coil Voltage: 24 V DC
Maximum Flow Rate: 120 L/min (≈ 32 GPM)
Maximum Operating Pressure (P, A, B ports): 315–350 bar (approx. 4500 psi)
Tank Port Pressure Rating (T port): typically 210 bar (≈ 3000 psi)
Seal Material: Viton (or standard hydro-oil compatible seals)
Fluid Compatibility: Petroleum-based hydraulic oils
Ambient / Operating Temperature Range: –20 °C to +70 °C (–4 °F to +158 °F)
Spool Type / Center Condition: Spool “2AJ 22” — closed/tandem-center (spring offset or spring-center depending config)
Manual Override: Plain (standard)
Construction / Body Material: Gray iron cast body, subplate-mountable
Fluid Cleanliness Requirement: ISO 19/17/14 (micron code)
Electrical Connector: ISO 4400 (DIN 43650) solenoid coil connector
Valve Mount Type: Subplate / manifold mounted (ISO / CETOP D05)
Performance Level: High-performance industrial directional control valve
Technical Specifications
Brand / Series: Vickers by Eaton, DG4V-3 series (60 Series design)
Model Code: DG4V-3-2AL-M-U-H7-60
Actuation Type: Solenoid operated
Coil Voltage: 24 V DC
Mounting / Interface: Subplate / manifold mount, ISO 4401-03 (D03) interface
Valve Type: Directional control valve (3- or 4-way)
Flow Rate (max): up to 21.0 GPM (≈ 80.0 L/min)
Max Operating Pressure (P, A, B ports): 350 bar (≈ 5000 psi)
Max Tank Port Pressure (T port): 210 bar (≈ 3000 psi)
Seal Material (standard): Viton (for multi-fluid compatibility) — nitrile (Buna-N) may be an option depending on variant.
Electrical Connection: ISO 4400 (DIN 43650) solenoid connector
Power Consumption (coil): approx. 30 W
Spool Type / Spring Arrangement: Spool “2AL” / Spool 2, Spring-offset (end-to-end) center arrangement
Manual Override: Plain (standard)
Fluid Compatibility: Petroleum-based hydraulic oils
Fluid Cleanliness Recommended: 19/17/14 micron code
Operating Temperature Range: –20 °C to +70 °C (–4 °F to +158 °F)
Body Material: Gray cast iron
Valve Size: D03 (ISO 4401)
Technical Specifications
Parameter / Spec Value / Description
Brand / Series Vickers by Danfoss — DG4V-3, 60 Series
Model Code DG4V32NMUH760
Valve Type Directional control valve, solenoid-operated
Actuation Type Solenoid operated (double-solenoid)
Coil Voltage 24 V DC
Electrical Connection ISO 4400 (DIN 43650) solenoid connector
Mounting / Interface Subplate / manifold mount, ISO 4401-03 (D03)
Maximum Flow Rate 21.0 GPM (≈ 80.0 L/min)
Maximum Operating Pressure (P, A, B ports) 350 bar (≈ 5000 psi)
Tank (T) Port Pressure Rating 210 bar (≈ 3000 psi)
Seal Material (standard) Viton
Fluid Compatibility Petroleum-based hydraulic oils
Fluid Cleanliness Requirement 19/17/14 (µm code)
Power Consumption (coil) 30 W
Stage / Spool Single stage; Spool type “Spool 2” (closed/tandem-center or equivalent per code)
Spring / Center Arrangement No spring detent (i.e. double solenoid, springless center)
Operating Temperature Range –20 °C to +70 °C (–4 °F to +158 °F)
Valve Mount Type Subplate / manifold mounted
Size (ISO) D03 (ISO 4401-03)
Valve Functionality 3- or 4-way directional control valve, suitable for typical industrial hydraulic circuits
Technical Specifications
Brand / Series: Vickers by Eaton — DG4V-5 series (20-series design)
Model Code: DG4V-5-2AJ-VMU620
Valve Type: Solenoid-operated directional control valve (4-way / 3-way, depending on port/spool configuration)
Mounting / Interface: Subplate / manifold mount, ISO 4401-05 (NFPA D05 / NG10)
Actuation: Solenoid operated (dual/ single depending on coil config)
Electrical Connection: ISO 4400 (DIN 43650) connector
Flow Capacity: up to 32 US gpm (≈ 120 L/min) — depending on spool and system conditions
Maximum Operating Pressure (Ports P, A, B): 315 bar (≈ 4500 psi)
Tank Port Pressure Rating (T port): typically up to 160–210 bar (depending on coil type / spec)
Seal Material (standard): Viton (O-rings / seals compatible with petroleum hydraulic oils)
Fluid Compatibility: Petroleum-based hydraulic oils
Spool Type: 2AJ (closed-center / all ports blocked in neutral, per spool code)
Spool Spring Arrangement: Spring-offset (end-to-end) — spring offsets spool toward one end when solenoids are de-energized
Manual Override: Plain (standard override in solenoid end only, if equipped)
Valve Mount Type: Subplate / manifold mounted (D05 / NG10)
Fluid Cleanliness Requirement: 19/17/14 micron code (recommended filtration)
Working (Ambient) Temperature Range: from –20 °C (–4 °F) up to about +40 °C (104 °F) for certain coils (for AC coils; DC-coil variants may permit higher ambient)
Valve Body Material: Cast gray-iron (robust industrial construction)
Technical Specifications
Parameter / Spec Value / Description
Brand / Series Vickers by Eaton — DG4V-5M, 22 Series
Model Code DG4V-5M-2AJ-M-KUP5-H7-22-EN194
Valve Type Directional control valve, solenoid-operated
Actuation Type Solenoid operated
Coil / Electrical Connection Integrated Deutsch connector (“KUP5”)
Coil Rating / Voltage 24 V DC
Flow Capacity up to 32 US gpm (≈ 120 L/min)
Maximum Operating Pressure (Ports P, A, B) 315 bar (≈ 4500 psi)
Tank Port Pressure Rating (Port T) 210 bar (≈ 3000 psi)
Seal Material (standard) Viton
Fluid Compatibility Petroleum-based hydraulic oils
Fluid Cleanliness Requirement 19/17/14 micron code
Spool Type Spool 22 (2AJ)
Spool Spring / Center Arrangement Spring-offset, end-to-end (spring returns spool toward one end when de-energized)
Stage Single-stage directional valve
Mounting / Interface Subplate / manifold mount, ISO 4401-05 (NG10 / D05) standard
Manual Override Plain manual override (standard)
Performance Level High-performance industrial directional valve
Operating Ambient Temperature Range –20 °C to +70 °C (–4 °F to +158 °F)
Power Consumption (coil) 38 W (when energized)
Electrical Response / Energising Time ~ 120–45 ms (typical)
Technical Specifications
Brand / Series: Vickers by Eaton — DG4V‑5, 20 Series
Model Code: DG4V‑5-8CJ-VM-U-H6-20
Valve Type: Solenoid-operated directional control valve (4-way / 3-way depending on spool)
Mounting / Interface: Subplate / manifold mount — ISO 4401‑05 (D05 / NG10)
Actuation: Solenoid operated (wet-armature)
Electrical Connection: ISO 4400 (DIN 43650) connector
Coil Rating / Type: 24 V DC
Maximum Flow Rate: Up to 32 US gpm (≈ 120 L/min)
Maximum Operating Pressure (P, A, B ports): 315 bar (≈ 4500 psi)
Tank (T) Port Pressure Rating: 160 bar (≈ 2320 psi)
Seal Material (standard): Viton
Fluid Compatibility: Petroleum-based hydraulic oils
Fluid Cleanliness Requirement: 19/17/14 micron code
Spool Type / Center Condition: Spool “8CJ”, spring-centered spool with four-land design
Stage: Single-stage directional valve
Manual Override: Plain (manual override at solenoid ends)
Valve Mount Type: Subplate / manifold mounted (ISO / NFPA standard)
Ambient / Operating Temperature Range: –20 °C to +70 °C (–4 °F to +158 °F)