Products
Products
home
honeywell
CC-pcnt01
CC-pcnt01: Isolated Pulse Counter Module

Key features in 4 words:
Isolated → Electrical noise immunity

Pulse Counter → Core function (digital pulse accumulation)

Module → Industrial embeddable format

Ultra-compact versions (for labels/BOMs):
Isolated Pulse Counter (CC-pcnt01)

Pulse Counter Mod. w/Isolation

More details >> Request a Quote >>
honeywell
CW4500
CW4500: 4500-Count Digital Counter Module

Key features in 6 words:
4500-Count: Max counting capacity

Digital: Discrete pulse input (e.g., PLC/encoder signals)

Counter: Core function

Module: Industrial embeddable hardware

Ultra-compact alternatives (for labels/schematics):
4500-Ct Digital Counter (CW4500)

Digital Counter Mod. 4500

Why this works:
"4500-Count" immediately conveys critical capacity (avoids misreading as frequency/voltage)

"Digital" specifies input type (essential for compatibility)

"Module" maintains consistency with previous codes (CD-820, RM7840G1022)

Omits redundant specs (e.g., voltage/speed) unless specified in datasheets

More details >> Request a Quote >>
honeywell
RM7840G1022
RM7840G1022: 10A/22VDC SPST-NO Relay Module

Key details included:
Electrical Rating: 10A current capacity at 22V DC

Contact Type: SPST-NO (Single-Pole Single-Throw, Normally Open)

Function: Relay Module (electromechanical switching device)

Alternative shorter formats:
10A/22VDC SPST Relay (RM7840G1022)

SPST-NO Relay, 10A @ 22VDC (RM7840G1022)

More details >> Request a Quote >>
honeywell
RTU SC-UMIX01
SC-UMIX01: Universal Signal Mixer/Converter Module (RTU Interface)

More details >> Request a Quote >>
honeywell
CC-PSP401
Honeywell CC-PSP401
Function: 120W Power Supply Module for Experion® C-Series I/O systems.

Key Features:

Input: 85–265 VAC (50/60 Hz) or 88–300 VDC (universal).

Output: 24 VDC, 5A (120W max).

Redundancy: Supports N+1 backup (hot-swappable).

Protections: Short-circuit, over-voltage, and thermal shutdown.

Compatibility:

Designed for Experion C200/C300 I/O chassis (e.g., CIOM/HIOM racks).

Robust Design:

Industrial-grade (-40°C to +70°C; 5–95% humidity).

Certifications: UL, CE, ATEX Zone 2.

More details >> Request a Quote >>
honeywell
FC-RUSIO-3224
honeywell
900P01-0301=2
Honeywell 900P01-0301=2
Function: Redundancy-Ready CPU Module for HC900 Process Control Systems.

Core Role:

Primary processor for executing control logic (PID, sequencing) in HC900 racks.

Supports hot-swap N+1 redundancy for fail-safe operation.

Key Specs:

I/O Capacity: Up to 16 modules (256 points).

Communications: Modbus TCP (Ethernet), Modbus RTU/ASCII (RS-232/485).

Environment: -40°C to +70°C industrial rating.

Integration:

Requires HC900 C70/C75 chassis; compatible with analog/digital I/O modules.

More details >> Request a Quote >>
honeywell
900C75-0460=2
Honeywell 900C75-0460=2
Function: 120W Power Supply Module for HC900 Process Control Systems.

Key Features:

Input: 85–265 VAC (50/60 Hz) or 88–300 VDC (universal).

Output: 24 VDC, 5A (regulated, 120W max).

Redundancy: Supports N+1 backup with identical modules.

Protections: Short-circuit, over-voltage, and thermal shutdown.

Compatibility:

Designed for HC900 C50/C70/C75 racks.

Robust Design:

Operates in -40°C to +70°C harsh environments.

Certifications: UL, CE, ATEX Zone 2.

More details >> Request a Quote >>
honeywell
HC900RR0-0101
Honeywell HC900RR0-0101
Function: CPU Module for Honeywell’s HC900 Hybrid Process Control System.

Core Role:

Acts as the central processor for HC900 racks, executing control logic (PID, sequencing, etc.).

Supports 16 I/O modules (max 256 points) for analog/digital signals.

Key Features:

Communications: Ethernet (Modbus TCP), RS-232/485 (Modbus RTU/ASCII), embedded web server.

Robust Operation: -40°C to +70°C industrial temperature range.

Power: 24 VDC (±10%).

More details >> Request a Quote >>
honeywell
XF524A
Honeywell XF524A
Function: Dual-Circuit Monitor Module for conventional fire alarm systems.

Key Features:

Monitors two independent dry-contact devices (e.g., flow switches, tamper switches, door holders).

Input Voltage: 15–32 VDC (regulated).

Low Power: Standby ≤1.5 mA; alarm ≤6 mA per circuit.

Wiring: Class A (Style Z) or Class B (Style Y) supervision.

More details >> Request a Quote >>
1 2
··· ···