Technical Parameters
Parameter Specification
Product Series Eaton NZM4
Product Type Electronic Trip Unit with Communication
Rated Current (In) 208-240A (as indicated by model suffix)
Rated Operational Voltage (Ue) Up to 690 V AC
Rated Insulation Voltage (Ui) 1000 V AC
Rated Frequency 50/60 Hz
Protection Functions L (Long-time), S (Short-time), I (Instantaneous), G (Ground Fault)
Communication Protocol Modbus RTU (via RS-485 interface)
Measurement Capabilities Current, Voltage, Power, Energy, Power Factor, Frequency
Display Integrated LCD display
Setting Adjustment Programmable via front interface or communication network
Mounting Integrated into compatible NZM4 circuit breaker frame
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Specification
Product Series Eaton DILM
Product Type AC Power Contactor
Rated Operational Current (Ie) 820 A
Rated Thermal Current (Ith) 820 A
Number of Poles 3
Auxiliary Contacts Typically 2 NO + 2 NC (configurable)
Rated Operational Voltage (Ue) Up to 1000 V AC
Control Coil Voltage Specific voltage indicated by XHB code variant
Motor Load Rating (AC-3) 400 kW at 400V AC
Electrical Life (AC-3) Up to 1 million operations
Mechanical Life Up to 10 million operations
Mounting Panel mounting or base plate mounting
Terminal Type Screw clamp or busbar connection
Standards Compliance IEC 60947-4-1, UL 508
Technical Parameters
Parameter Specification
Product Series Eaton DILM
Product Type AC Power Contactor
Rated Operational Current (Ie) 820 A
Rated Thermal Current (Ith) 820 A
Number of Poles 3
Rated Operational Voltage (Ue) Up to 1000 V AC
Control Coil Voltage Specific voltage indicated by XKB code variant
Motor Load Rating (AC-3) 400 kW at 400V AC
Electrical Life (AC-3) Up to 1 million operations
Mechanical Life Up to 10 million operations
Mounting Panel mounting or base plate mounting
Terminal Type Screw clamp or busbar connection
Special Features Custom configuration as indicated by "-S" suffix
Standards Compliance IEC 60947-4-1, UL 508
Technical Parameters
Parameter Specification
Product Series Eaton DILM
Product Type AC Power Contactor
Rated Operational Current (Ie) 820 A
Rated Thermal Current (Ith) 820 A
Number of Poles 3
Auxiliary Contacts Configurable (typically 2 NO + 2 NC)
Rated Operational Voltage (Ue) Up to 1000 V AC
Control Coil Voltage Various voltages available (specific voltage indicated by XMV code)
Motor Load Rating (AC-3) 400 kW at 400V AC
Electrical Life (AC-3) Up to 1 million operations
Mechanical Life Up to 10 million operations
Mounting Panel mounting or base plate mounting
Terminal Type Screw clamp or busbar connection
Standards Compliance IEC 60947-4-1, UL 508
Technical Parameters
Parameter Specification
Product Series Eaton EIS
Product Type Load Break Switch / Disconnector
Rated Operational Current (Ie) 80 A
Number of Poles 4 (3 phases + neutral)
Rated Operational Voltage (Ue) 400 V AC
Rated Insulation Voltage (Ui) 690 V AC
Utilization Category AC-22A / AC-23A
Mechanical Life ≥ 20,000 operations
Electrical Life ≥ 5,000 operations at rated current
Protection Degree IP20 (when properly installed in enclosure)
Mounting DIN Rail (35 mm)
Terminal Type Screw clamp
Connection Capacity Suitable for rigid and flexible conductors
Standards Compliance IEC 60947-3
Technical Parameters
Parameter Specification
Product Series Eaton EIS
Product Type Load Break Switch / Disconnector
Rated Operational Current (Ie) 80 A
Number of Poles 3
Rated Operational Voltage (Ue) 400 V AC
Rated Insulation Voltage (Ui) 690 V AC
Utilization Category AC-22A / AC-23A
Mechanical Life ≥ 20,000 operations
Electrical Life ≥ 5,000 operations at rated current
Protection Degree IP20 (when properly installed in enclosure)
Mounting DIN Rail (35 mm)
Terminal Type Screw clamp
Connection Capacity Suitable for rigid and flexible conductors
Standards Compliance IEC 60947-3
Technical Parameters
Parameter Specification
Product Series Eaton EIS
Product Type Load Break Switch / Disconnector
Rated Operational Current (Ie) 63 A
Number of Poles 4 (3 phases + neutral)
Rated Operational Voltage (Ue) 400 V AC
Rated Insulation Voltage (Ui) 500-690 V AC
Utilization Category AC-22A / AC-23A
Mechanical Life ≥ 20,000 operations
Electrical Life ≥ 5,000 operations at rated current
Protection Degree IP20 (when properly installed in enclosure)
Mounting DIN Rail (35 mm)
Terminal Type Screw clamp
Torque Requirement Typically 2.5-3.0 Nm
Standards Compliance IEC 60947-3
Technical Parameters
Parameter Specification
Product Series Eaton EIS
Product Type Load Break Switch / Disconnector
Rated Operational Current (Ie) 63 A
Number of Poles 3
Rated Operational Voltage (Ue) 400 V AC
Rated Insulation Voltage (Ui) 500 V AC
Utilization Category AC-22A or AC-23A
Mechanical Life Typically 20,000 operations
Electrical Life Typically 5,000 operations at rated current
Protection Degree IP20 (when mounted in appropriate enclosure)
Mounting DIN Rail (35 mm)
Terminal Type Screw clamp
Standards Compliance IEC 60947-3
Technical Parameters
Parameter Specification
Product Series Eaton NZN2 / NZN3
Product Type Undervoltage Release (UVR) / Shunt Release
Rated Control Supply Voltage (Us) 24 V DC
Trip Voltage Range Typically trips between 70% and 35% of Us (e.g., ~16.8V to ~8.4V)
Power Consumption Typically <15 W
Mounting Integrated into a compatible NZN2/NZN3 circuit breaker
Function Trips the breaker when control voltage is lost; prevents closing when de-energized
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Specification
Product Series Eaton NZM4
Product Type Undervoltage Release (UVR) / Shunt Release
Rated Control Supply Voltage (Us) 24 V DC
Trip Voltage Range Typically trips between 70% and 35% of Us (e.g., ~16.8V to ~8.4V)
Mounting Integrated into a compatible NZM4 circuit breaker frame
Function Trips the breaker when control voltage is lost; prevents closing when de-energized
Standards Compliance IEC 60947-2