Parameter Specification
Product Model MTL5521
Product Line Eaton MTL Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated 4-20 mA DC signal.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).
Parameter Specification / Inference
Product Model T0-4-8344/I1/SVB
Product Line Eaton T0 Power Contactor
Rated Operational Current (Ie) Typically up to ~25 A at AC-3, 400V
Rated Operational Voltage (Ue) Up to 690 V AC
Number of Main Poles 4
Coil Voltage 110-120 V AC, 50/60 Hz
Auxiliary Contacts 1 NO (Normally Open)
Mounting Style Base Mounting with Screw Terminals (SVB)
Electrical Life > 1 million operations (at rated load)
Mechanical Life > 10 million operations
Standards Compliance IEC 60947-4-1, UL 508
Parameter Specification / Inference
Product Model E56ADL50UAD01
Product Line Eaton E56 Thermostats
Product Type Digital Programmable Room Thermostat
Display LCD
Power Supply 24 V AC
Control Output Analog Output: 0-10 V DC
Sensor Input Built-in room temperature sensor (typical)
Setpoint Range Typically adjustable (e.g., 5°C to 30°C)
Accuracy Typically ±0.5°C
Control Action Likely Heating and Cooling mode selectable
Programmability Yes, typically 7-day programmable with multiple periods per day
Mounting Standard wall mount
Enclosure Color Typically white
Parameter Specification
Product Model MTL4546Y
Product Line Eaton MTL4500+ Series Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated Voltage Output (e.g., 0-10 V DC or other programmable range, MUST be verified from datasheet).
Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher)
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (MUST be verified from datasheet):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, etc.
Parameter Specification / Inference
Product Model ZM1/2-XV4
Product Line Eaton ZM (RCCB)
Device Type Residual Current Circuit Breaker (RCCB)
Number of Poles 2 Poles (1P + N)
Rated Current (In) This is not specified in this part of the code. The ZM frame accepts a range of current ratings (e.g., 16A, 25A, 40A, 63A) which is a separate specification.
Rated Operational Voltage (Ue) 230 V AC
Rated Residual Operating Current (IΔn) 40 mA
Type of Residual Current AC (Sensitive to alternating sinusoidal residual currents)
Tripping Time Instantaneous (Typically < 300 ms for 1x IΔn, and < 40 ms for 5x IΔn as per standards)
Breaking Capacity According to IEC 61009-1 (e.g., 6000 A)
Mounting DIN Rail Mount (35 mm)
Standards Compliance IEC 61008-1, VDE 0664, etc.
Parameter Specification
Product Model MTL4041B
Product Line Eaton MTL Signal Conditioners & Isolators
Function Single-channel Signal Isolator / Repeater
Input Signal 4-20 mA
Output Signal Isolated 4-20 mA
Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher)
Power Supply Typically 20-30 V DC
Accuracy Typically better than ±0.1% of span
Load Capacity Typically up to 850 Ω (at 20 mA)
Line Fault Detection Yes, can be configured for indication on open or short circuit input.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification
Product Model MTL7787P+
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification
Product Model MTL7767+
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification
Product Model MTL7782+
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification / Inference
Product Model IOP32
Product Line Eaton Industrial Control Devices
Product Type Illuminated Pushbutton
Mounting Hole Diameter 32 mm
Protection Rating NEMA 4X / IP65
Contact Block Not included in base model. Must be selected separately
Lens Color Not specified in base model. Various colors available
Illumination Voltage Not specified in base model. Requires separate selection of lamp holder or LED module
Rated Operational Current Depends on the contact block used
Operator Material Thermoplastic or metal, designed for durability.
Mounting Panel-mounted from the front with a securing nut.