Parameter Specification
Product Series Eaton PLHTX (Accessory for PLH/PLHT MCB)
Model Number PLHTX-D100/4
Description Residual Current Release Module, for 4-Pole MCB, 100A
Compatible With Eaton PLH/PLHT series, 4-pole, 100A Miniature Circuit Breaker
Rated Current of Assembly 100 A
Number of Poles 4 Poles (3 Phase + Neutral)
Rated Residual Operating Current (IΔn) 30 mA
Residual Current Type Type A (for alternating and pulsating direct currents)
Rated Voltage 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PLH/PLHT MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PLD101X (Accessory for PL10 MCB)
Model Variants PLD101X-C10 (for 10A MCB), PLD101X-C40 (for 40A MCB)
Description Residual Current Release Module, for 1P+N MCB, C-Curve
Compatible With Eaton PL10 series, 2-pole (1P+N), C-Curve Miniature Circuit Breakers
Rated Current of Assembly 10 A (for C10) / 40 A (for C40)
Number of Poles 2 Poles (1 Phase + Neutral)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 230V AC (1P+N)
Mounting Snaps onto the side of a compatible PL10 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL9X (Accessory for PL9 MCB)
Model Number PL9X-C32
Description Residual Current Release Module, for 1P+N (2-Pole) MCB, 32A
Compatible With Eaton PL9 series, 2-pole (1P+N), 32A Miniature Circuit Breaker
Rated Current of Assembly 32 A
Number of Poles 2 Poles (1 Phase + Neutral)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 230V AC (1P+N)
Mounting Snaps onto the side of a compatible PL9 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL9X (Accessory for PL9 MCB)
Model Number PL9X-B40
Description Residual Current Release Module, for 3-Pole MCB, 40A
Compatible With Eaton PL9 series, 3-pole, 40A Miniature Circuit Breaker
Rated Current of Assembly 40 A
Number of Poles 3 Poles (3 Phase)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 400V AC (3P)
Mounting Snaps onto the side of a compatible PL9 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL9X
Model Number PL9X-C63
Description Residual Current Release Module, for 4-Pole MCB, 63A
Compatible With Eaton PL9 series, 4-pole, 63A Miniature Circuit Breaker
Rated Current of Assembly 63 A
Number of Poles 4 Poles (3 Phase + Neutral)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PL9 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL10X
Model Number PL10X-C32
Description Residual Current Release Module, for 4-Pole MCB, 32A
Compatible With Eaton PL10 series, 4-pole, 32A Miniature Circuit Breaker
Rated Current of Assembly 32 A
Number of Poles 4 Poles (3 Phase + Neutral)
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PL10 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton PL10X (Accessory for PL10 MCB)
Model Number PL10X-D20
Description Residual Current Release Module, for 4-Pole MCB, 20A
Compatible With Eaton PL10 series, 4-pole, 20A Miniature Circuit Breaker
Rated Current of Assembly 20 A
Number of Poles 4 Poles
Rated Residual Operating Current (IΔn) Typically 30 mA
Residual Current Type Typically Type A
Rated Voltage 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PL10 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE
Parameter Specification
Product Series Eaton EAR2..TO (Electronic Overload Relay)
Model Number EAR2TO012S1
Description Electronic Overload Relay, 1.0-1.6A, Self-Protected, Screw Terminals
Motor Current Setting Range (FLA) 1.0 - 1.6 A
Poles 3 (for 3-phase motor protection)
Rated Operational Voltage (Ue) 690V AC
Rated Supply Voltage (Us) 24V AC/DC - 240V AC/DC (for the control circuit)
Protection Functions Overload (Class 10, 20, 30 adjustable)
Phase Loss
Phase Unbalance
Jam / Stall Protection
Earth Fault Protection (Optional, may require external CT)
Self-Protected Feature Yes (Integral HBC fuse for short-circuit protection of the control unit)
Auxiliary Contacts 1 NO + 1 NC (95-96 / 97-98)
Terminals Screw Terminals
Mounting Mounts directly onto compatible contactors (e.g., Eaton DIL series)
Communication Optional communication modules (e.g., PROFIBUS, Modbus) available
Standards & Certifications IEC/EN 60947-4-1, UL 508, CE, cULus
Parameter Specification
Product Series Eaton PLD9X (Accessory for PL9 MCB)
Model Number PLD9X-6/2/D/003
Description Residual Current Release Module, for 2-Pole MCB, Type A, 30mA
Compatible With Eaton PL9 series, 2-pole Miniature Circuit Breakers
Max. Rated Current of Assembly Up to 63A (When combined with a compatible PL9 MCB)
Rated Residual Operating Current (IΔn) 30 mA
Residual Current Type Type A (for alternating and pulsating direct currents)
Rated Voltage 230V AC (1P+N) / 400V AC (3P+N)
Mounting Snaps onto the side of a compatible PL9 MCB on a DIN Rail.
Standards & Certifications IEC 61009-1, CE