Parameter Specification Notes / Typical Value for this Series
Product Model NZM1/2-XCR-S/MODAN
Product Line NZM (Molded Case Circuit Breaker)
Rated Operational Voltage (Ue) Typically up to 690V AC
Rated Current (In) Depends on the Rating Plug. The frame size NZM1/2 supports a range (e.g., up to 63A or 125A). The actual current is set by a separate rating plug.
Rated Ultimate Breaking Capacity (Icu) Standard Breaking Capacity ("S") Specific kA value at a given voltage (e.g., 25kA @ 415V) must be verified from datasheet.
Trip Unit Type Electronic (XCR)
Protection Functions
L - Long-Time (Overload)
S - Short-Time (Short-Circuit)
I - Instantaneous
G - Ground Fault
All thresholds are adjustable.
Communication Capability Yes (Typically PROFIBUS-DP or Modbus) The "X" in XCR often denotes communication readiness. Requires a separate communication module.
Auxiliary Contacts Can be equipped Via add-on modules.
Mounting Fixed or Plug-in (as per MODAN kit) The "MODAN" kit facilitates specific mounting.
Standards Compliance IEC 60947-2, UL 489, etc.
Parameter Specification
Product Model FAZ-B63/3N
Product Line Eaton FAZ B-Series (Miniature Circuit Breaker)
Number of Poles 3 Poles + Neutral (3P+N)
Rated Current (In) 63 A
Tripping Characteristic B-Curve (Instantaneous tripping between 3 to 5 times rated current). Suitable for resistive and low inductive loads.
Rated Operational Voltage (Ue) 230/400 V AC
Rated Insulation Voltage (Ui) 500 V AC
Rated Impulse Withstanding Voltage (Uimp) 4 kV
Rated Breaking Capacity (Icn) Typically 10 kA at 230/400V AC according to IEC 60898-1. (Please confirm with local catalog as higher capacity versions may exist).
Standards IEC/EN 60898-1, IEC/EN 60947-2
Terminal Connection Suitable for cables up to 35 mm² (copper).
Mounting Standard DIN Rail (35 mm) mounting.
Mechanical Life Typically > 20,000 cycles
Electrical Life Typically > 10,000 cycles
Torque Screw Typically 3.0 N·m
Parameter Specification
Product Model LS-11DA
Product Type Heavy-Duty Limit Switch
Contact Arrangement 1 NO (Normally Open) + 1 NC (Normally Closed) - Single Circuit, Double Break
Contact Operation Maintained Contact
Switch Mechanism Slow Action (Snap-Action)
Rated Operational Current Typically 10 A @ 600 V AC / 0.5 A @ 600 V DC (Specific values depend on thermal and inductive load)
Electrical Life Typically 1 to 2 million operations (at rated load)
Mechanical Life Typically 10 million operations
Enclosure Rating NEMA 4, 4X, 6P, 13; IP67 (Dust-tight and protected against immersion)
Housing Material Typically Zinc Die Cast
Operating Head Various actuator types available (e.g., roller lever, plunger) - the "DA" suffix may specify a particular type.
Terminal Type Screw terminals
Conduit Opening Standard ½" NPT
Temperature Range Typically -20°C to +120°C (-4°F to +248°F)
Standards Compliance UL Listed, cULus Listed, CE
Parameter Specification
Product Model BLR-CX06R
Sensor Type Inductive Proximity Sensor
Body Shape Rectangular
Detection Type Shielded (Embeddable)
Output Type DC 3-wire
Output Configuration NPN Normally Open (NO)
Supply Voltage 10 to 30 V DC
Rated Sensing Distance 2 mm (±10%)
Setpoint 0 to 1.62 mm
Hysteresis ≤ 10% of rated sensing distance
Standard Target Fe 12x12x1 mm (Mild Steel)
Response Frequency 500 Hz
Protection Circuit Reverse Polarity Protection, Short-circuit protection, Overcurrent protection
Protection Rating IP67
Housing Material Nickel-plated brass
Connection Type Pre-wired cable (2m standard length is common, but please verify)
Operating Temperature -25 to 70°C
Compliance CE
Parameter Specification
Product Model MTL-779+
Product Line Eaton MTL Signal Conditioners & Isolators
Function 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal 4-20 mA DC (Isolated)
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC (for standard models)
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).
Parameter Specification
Product Model EMR6-I15-A -1
Product Line Eaton EMR6 Electronic Overload Relay
Rated Operational Voltage (Ue) Up to 690 V AC
Motor Full-Load Current Range Depends on the installed Heater Element / Rating Plug. The I15 frame covers a specific range (e.g., 0.15 A to 25 A). The exact value is set by a removable rating plug.
Tripping Class Selectable (e.g., Class 5, 10, 15, 20, 30)
Protection Functions
Phase Loss / Unbalance
Overload
Locked Rotor / Stall
Jam / High Current
Ground Fault (Earth Fault)
Auxiliary Contacts Typically includes at least one 95-96 (NC) fault contact and one 97-98 (NO) alarm contact.
Reset Mode Manual Reset (inferred from "-1" suffix), with options for automatic reset.
Mounting Designed to be mounted directly onto a corresponding Eaton contactor (e.g., DIL series) without tools.
Ambient Temperature -25°C to +60°C
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Parameter Specification / Inference
Product Model T5-4-I5682/I5/SVB
Product Line Eaton T5 Power Contactor
Rated Operational Current (Ie) ~ 32 A at AC-3, 400V
Rated Operational Voltage (Ue) Up to 690 V AC
Number of Main Poles 4
Coil Voltage 24 V DC
Auxiliary Contacts 1 NO (Normally Open) + 1 NC (Normally Closed)
Mounting Style Base Mounting with Screw Terminals (SVB)
Terminal Type Screw Clamp
Electrical Life > 1 million operations (at rated load)
Mechanical Life > 10 million operations
Standards Compliance IEC 60947-4-1, UL 508
Parameter Specification
Product Model PFS3322
Product Line Eaton Bussmann PFS (High Performance Class Fuse)
Fuse Type Current-Limiting
Ampere Rating 200 A
Voltage Rating AC 600 V AC
Voltage Rating DC Typically 300 V DC (Please verify for specific DC applications)
Interrupting Rating 200,000 A RMS (200 kA) at 600V AC
Standards & Approvals UL Listed (Class J), CSA Certified
Time-Current Characteristic Fast-Acting
Label Color Black (Standard for this amperage in PFS series)
Terminal Type Knife Blade (Standard for Class J fuses)
Dimensions (Body) Standard Class J dimensions.
Parameter Specification
Product Model MTL4851
Product Line Eaton MTL Signal Conditioners & Isolators
Function 1-channel Signal Isolator
Input Signal 4-20 mA (Sourced from a 2-wire or 3-wire transmitter)
Output Signal 4-20 mA (Isolated)
Power Supply Typically 20-30 V DC
Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher)
Accuracy Typically better than ±0.1% of span
Load Capacity Typically up to 850 Ω (at 20 mA)
Ambient Temperature Range -20°C to +60°C
Mounting DIN-Rail Mount (Standard 35 mm)
Field-side Intrinsic Safety Can be used in Intrinsic Safety (IS) loops when installed with an approved associated apparatus (safety barrier/isolator) on its input.
Approvals ATEX, IECEx, FM, CSA (for general purpose and IS applications)
Parameter Specification
Product Model NZMH2-S63
Product Line Eaton NZM MCCB (NZMH2 series)
Poles 2-Poles (Inferred from "H2", where "2" typically means 2 poles)
Rated Current (In) 63 A (Fixed)
Rated Operational Voltage (Ue) 400/415 V AC
Rated Insulation Voltage (Ui) 690 V AC
Rated Ultimate Breaking Capacity (Icu) Standard Capacity (e.g., 25 kA @ 415V AC) 必须根据官方数据表确认
Trip Unit Type Thermal-Magnetic (Non-adjustable)
Tripping Characteristic According to IEC 60947-2 (e.g., Curve B or similar for MCCBs)
Mounting Fixed Mounting
Terminal Connection Suitable for copper or aluminum cables (specific sizes to be verified)
Standards Compliance IEC/EN 60947-2
Electrical Life Typically several thousand cycles at rated current