Products
Products
home
eaton
DILM32-XTEE11(RAC240)
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Model DILM32-XTEE11 Catalog Reference RAC240 Product Type Contactor Relay (4-pole, changeover contacts) Number of Contacts 4 Contact Type 4 Changeover (CO) / Form C (Each contact: 1 NO + 1 NC) Rated Operational Current (Iₑ) 10 A (at 250V AC) Rated Thermal Current (Ith) 16 A Rated Insulation Voltage (Ui) 500 V AC Control Coil Voltage 24 V DC Special Feature Latching (Impulse) Version (Mechanically held) Electrical Life > 1 x 10⁶ operations Mechanical Life > 10 x 10⁶ operations Mounting 35 mm DIN Rail Terminal Type Cage Clamp (Spring-loaded) Approvals / Certifications CE, cULus, CCC, IEC/EN 60947-5-1

More details >> Request a Quote >>
eaton
ED6-10/1N/D/003
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series ED6 Product Model ED6-10/1N/D/003 Product Type Type 2 / Class II Surge Protective Device (SPD) Rated Voltage 230/400 V AC Nominal System Voltage 230 V AC (Single-Phase + N) Protection Mode 1-Pole + N (L-N, N-PE) Max. Discharge Current (Imax - 8/20 µs) 10 kA per pole Nominal Discharge Current (In - 8/20 µs) 5 kA Voltage Protection Level (Up) ≤ 1.5 kV Response Time < 25 ns Backup Fuse Recommendation 16 A gG/gL (or according to local regulations) Status Indication Visual (Green: OK; Red: End-of-Life) & Remote Signalling Contact Remote Contact 1 Changeover Contact (SPDT) Mounting 35 mm DIN Rail (EN 60715) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>
eaton
PXK-B16/1N/003-A
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series PXK Product Model PXK-B16/1N/003-A Product Type Type 2 / Class II Surge Protective Device (SPD) Rated Voltage (Uc) 230/400 V AC Nominal System Voltage 230 V AC (Single-Phase + N) Protection Mode 1-Pole + N (L-PE, N-PE) Max. Discharge Current (Imax - 8/20 µs) 16 kA per mode Nominal Discharge Current (In - 8/20 µs) 8 kA Voltage Protection Level (Up) ≤ 1.5 kV Response Time < 25 ns Backup Overcurrent Protection (Recommended) 16 A to 63 A gG/gL (or per local regulations) Status Indication Visual Indicator (Green: OK; Red: End-of-Life) Remote Signalling Contact 1 Changeover Contact (SPDT) Mounting 35 mm DIN Rail (EN 60715) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>
eaton
PFIM-40/4/003
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series PFIM Product Model PFIM-40/4/003 Product Type Type 1 + Type 2 Combined SPD Rated Voltage (Uc) 230/400 V AC Nominal System Voltage 400 V AC (Three-Phase + N) Protection Mode 3-Poles + Neutral (3P+N) (L1-PE, L2-PE, L3-PE, N-PE) Lightning Impulse Current (Iimp - 10/350 µs) 20 kA per pole Max. Discharge Current (Imax - 8/20 µs) 40 kA per pole Voltage Protection Level (Up) ≤ 2.5 kV Response Time < 100 ns Backup Overcurrent Protection Required (specific rating per local regulations and installation manual) Status Indication Visual Indicator (Green: OK; Red: End-of-Life) Remote Signalling Contact 1 Changeover Contact (SPDT) Special Feature Thermal Disconnector Mounting Mounting Plate (for panel mounting) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>
eaton
PLD9-10/1N/C/003
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series PLD9 Product Model PLD9-10/1N/C/003 Product Type Type 2 / Class II Surge Protective Device (SPD) Rated Voltage (Uc) 230/400 V AC Nominal System Voltage 230 V AC (Single-Phase + N) Protection Mode 1-Pole + N (L-PE, N-PE) Max. Discharge Current (Imax - 8/20 µs) 10 kA per mode Nominal Discharge Current (In - 8/20 µs) 5 kA Voltage Protection Level (Up) ≤ 1.5 kV Response Time < 25 ns Backup Overcurrent Protection (Recommended) 16 A gG/gL (or per local regulations) Status Indication Visual Indicator (Green: OK; Red: End-of-Life) Remote Signalling Contact 1 Changeover Contact (SPDT) Mounting 35 mm DIN Rail (EN 60715) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>
eaton
PLD9-C20
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series PLD9 Product Model PLD9-C20 Product Type Type 2 / Class II Surge Protective Device (SPD) Rated Voltage (Uc) 230/400 V AC Nominal System Voltage 230 V AC (Single-Phase) Protection Mode 1-Pole (L-PE) Max. Discharge Current (Imax - 8/20 µs) 20 kA Nominal Discharge Current (In - 8/20 µs) 10 kA Voltage Protection Level (Up) ≤ 1.5 kV Response Time < 25 ns Backup Overcurrent Protection (Recommended) 16 A gG/gL (or per local regulations) Status Indication Visual Indicator (Green: OK; Red: End-of-Life) Remote Signalling Contact Not Available Mounting 35 mm DIN Rail (EN 60715) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>
eaton
PF1M-63/4/003
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series PF1M Product Model PF1M-63/4/003 Product Type Type 1 + Type 2 Combined SPD Rated Voltage (Uc) 230/400 V AC Nominal System Voltage 400 V AC (Three-Phase + N) Protection Mode 3-Poles + Neutral (3P+N) (L1-PE, L2-PE, L3-PE, N-PE) Lightning Impulse Current (Iimp - 10/350 µs) 25 kA per pole Max. Discharge Current (Imax - 8/20 µs) 63 kA per pole Voltage Protection Level (Up) ≤ 2.5 kV Response Time < 100 ns Backup Overcurrent Protection Required (specific rating per local regulations and installation manual) Status Indication Visual Indicator (Green: OK; Red: End-of-Life) Remote Signalling Contact 1 Changeover Contact (SPDT) Special Feature Thermal Disconnector Mounting Mounting Plate (for panel mounting) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>
eaton
PFlM-25/2/003
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series PF1M Product Model PF1M-25/2/003 Product Type Type 1 + Type 2 Combined SPD Rated Voltage (Uc) 230/400 V AC Nominal System Voltage 230 V AC (Single-Phase + N) Protection Mode 1-Pole + Neutral (1P+N) (L-PE, N-PE) Lightning Impulse Current (Iimp - 10/350 µs) 12.5 kA per pole Max. Discharge Current (Imax - 8/20 µs) 25 kA per pole Voltage Protection Level (Up) ≤ 2.0 kV Response Time < 100 ns Backup Overcurrent Protection Required (specific rating per local regulations and installation manual) Status Indication Visual Indicator (Green: OK; Red: End-of-Life) Remote Signalling Contact 1 Changeover Contact (SPDT) Special Feature Thermal Disconnector Mounting Mounting Plate (for panel mounting) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>
eaton
PLD9-32/1N/C/003
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series PLD9 Product Model PLD9-32/1N/C/003 Product Type Type 2 / Class II Surge Protective Device (SPD) Rated Voltage (Uc) 230/400 V AC Nominal System Voltage 230 V AC (Single-Phase + N) Protection Mode 1-Pole + Neutral (1P+N) (L-PE, N-PE) Max. Discharge Current (Imax - 8/20 µs) 32 kA per mode Nominal Discharge Current (In - 8/20 µs) 15 kA Voltage Protection Level (Up) ≤ 1.5 kV Response Time < 25 ns Backup Overcurrent Protection (Recommended) 25 A gG/gL (or per local regulations) Status Indication Visual Indicator (Green: OK; Red: End-of-Life) Remote Signalling Contact 1 Changeover Contact (SPDT) Mounting 35 mm DIN Rail (EN 60715) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>
eaton
PLD9X-10/1N/C/03-A
Technical Parameters Parameter Category Specification / Value Brand Eaton Product Series PLD9X Product Model PLD9X-10/1N/C/03-A Product Type Type 2 / Class II Surge Protective Device (SPD) Rated Voltage (Uc) 230/400 V AC Nominal System Voltage 230 V AC (Single-Phase + N) Protection Mode 1-Pole + Neutral (1P+N) (L-PE, N-PE) Max. Discharge Current (Imax - 8/20 µs) 10 kA per mode Nominal Discharge Current (In - 8/20 µs) 5 kA Voltage Protection Level (Up) ≤ 1.5 kV Response Time < 25 ns Backup Overcurrent Protection (Recommended) 16 A gG/gL (or per local regulations) Status Indication Visual Indicator (Green: OK; Red: End-of-Life) Remote Signalling Contact 1 Changeover Contact (SPDT) Mounting 35 mm DIN Rail (EN 60715) Connection Screw Terminal Approvals / Certifications CE, IEC 61643-11

More details >> Request a Quote >>