Technical Specifications
Parameter Specification
Valve Type Diaphragm Control Valve
Inlet Size DN65 (2½ inch)
Outlet Size DN50 (2 inch)
Pressure Rating ANSI Class 150 or 300 (specific to order)
Flow Characteristic Equal Percentage or Linear (trim dependent)
Actuator Type Diaphragm Actuator
Body Material Carbon Steel (WCB) or other specified materials
Trim Material Stainless Steel (standard)
Temperature Range -20°F to 400°F (-29°C to 204°C) - standard
End Connections Flanged (RF facing standard)
Technical Specifications
Parameter Specification
Model DVP-2000
Type Digital Valve Positioner
Input Signal 4-20 mA (2-wire) with HART protocol
Output Signal Pneumatic pressure to actuator (3-15, 6-30 psi or other ranges)
Supply Air Pressure 20-150 psig (1.4-10.3 bar)
Air Consumption < 0.15 SCFM (4.2 NLPM) at steady state
Accuracy ≤ 0.5% of span (including linearity, dead band, hysteresis)
Travel Feedback Non-contact magnetic position sensing
Enclosure Rating NEMA 4X (IP66/67)
Ambient Temperature -40°F to 185°F (-40°C to 85°C)
Mounting Direct mount to Fisher and other manufacturers' actuators
Communication HART 5/7 protocol
Technical Specifications
Parameter Specification
Model KJ1501x1-BC1
Type Control Valve Assembly
Valve Style Globe Valve (typical for KJ series)
Valve Size Specific size encoded in "KJ1501x1" (e.g., 1.5 inch or similar)
Pressure Class ANSI Class 150 or 300 (encoded in model number)
Actuator Type Pneumatic Spring-Diaphragm ("BC1" configuration)
Actuator Action Spring-Return (fail-safe)
Air Signal 3-15 psig (0.2-1.0 bar) standard
Flow Characteristic Equal Percentage or Linear (trim dependent)
End Connections Flanged (RF facing standard)
Temperature Range -20°F to 450°F (-29°C to 232°C) - standard
Technical Specifications
Parameter Specification
Part Number 159000677
Description Repair Kit or Component Assembly
Kit Type Maintenance/Repair Kit for Fisher valves or actuators
Contents Specific components vary (typically includes seals, gaskets, O-rings, fasteners)
Compatibility Designed for specific Fisher valve or actuator models
Materials Buna-N, PTFE, Stainless Steel, or other engineered materials
Temperature Rating Dependent on component materials (typically -20°F to 400°F / -29°C to 204°C)
Pressure Rating Matches original equipment specifications
Parameters / Specifications
Model: 3‑9900.394 Direct Conductivity/Resistivity Module
Compatible With: GF Signet 9900 transmitter platform
Input Sensor Types: Conductivity and resistivity electrodes (e.g., Signet 2819 to 2823; Signet 2839 to 2842)
Function: Converts electrode signals into conditioned output suitable for the 9900 transmitter; enables conductivity, resistivity, and salinity measurement via the 9900 digital inputs
Weight: Approximately 0.2 lb (~0.09 kg) in one listing
Dimensions: Approx. 4″ × 4″ × 4″ (~101 mm × 101 mm × 101 mm) in one listing
Mounting/Format: Module card designed to slide into or attach to the 9900 transmitter enclosure
Alternate Part Number: 159 001 699 (associated part number for this module)
Application: Water quality monitoring, process analytics, inline conductivity/resistivity measurement in industries such as water treatment, food & beverage, semiconductor, aquaculture, marine, pulp & paper
Key Features:
Direct interface of conductivity/resistivity electrodes to transmitter
Supports salinity measurement when combined with the 9900 digital S3L inputs
Simplifies wiring and integration by using a dedicated module rather than separate transmitter for each sensor type
Parameter Specification / Description
Model Series Fisher 655 Actuator
Type Scotch-Yoke / Rack and Pinion Pneumatic Piston Actuator
Configurations Double-Acting (Air-to-Air): Requires air to open and close. No fail-safe spring.
Spring-Return: Provides fail-safe action (fail-open or fail-closed) upon air supply loss.
Actuator Sizes 30, 40, 50, 60, 70, 80 (The number indicates the piston diameter in millimeters)
Standard Supply Pressure 40 to 120 psi (2.8 to 8.3 bar)
Temperature Range Standard: -4° to 180°F (-20° to 82°C)
Low Temp.: -40°F (-40°C) with optional seals & lubrication
Mounting Directly to ISO 5211 mounting pads and NAMUR (VDI/VDE 3845) compliant valves.
Accessory Mounting NAMUR standard for easy attachment of solenoid valves, limit switches, and positioners.
Body Material Standard: Aluminum with corrosion-resistant epoxy coating.
Optional: Stainless Steel (e.g., for corrosive environments).
Spring Material Carbon Steel
Piston Seals Standard: Buna-N
Optional: Ethylene Propylene (EPDM), Fluorocarbon (Viton)
Parameter Specification
Model MR95H
Product Line Fisher MR Series I/P Converter
Device Type Current-to-Pressure (I/P) Converter
Input Signal 4-20 mA DC (Standard two-wire)
Output Pressure Range Standard: 3-15 psig (0.2-1.0 bar)
Other Ranges: Available, such as 3-27 psig, 6-30 psig.
Supply Pressure 20 psig (1.4 bar) minimum, 40 psig (2.8 bar) typical, up to 120 psig (8.3 bar) maximum. Must be at least 3-5 psi above the required output pressure.
Air Consumption Static (No Signal): Typically ≤ 0.2 scfm (0.0057 Nm³/min)
Dynamic (With Signal): Varies with output.
Accuracy Typically ±0.5% of span (including linearity, hysteresis, and dead band)
Supply Connection 1/4 in. NPT (F)
Output Connection 1/4 in. NPT (F)
Mounting Standard: Panel mount (for 1-1/8 in. or 29mm diameter hole)
Optional: Manifold mount, surface mount, or 35mm DIN rail kit.
Enclosure Rating NEMA 4X (IP66) when properly mounted.
Material Aluminum enclosure with polyurethane coating.
Ambient Temperature Range -20° to 180°F (-29° to 82°C)
Parameter Specification
Model 39A9228X012
Product Line Fisher Type 678C
Device Type Self-Relieving Supply Pressure Regulator
Supply Pressure Range Up to 300 psig (20.7 bar)
Output Pressure Range 3 to 65 psig (0.2 to 4.5 bar) Adjustable via the spring knob.
Relieving Capacity Up to 25 scfm (0.71 Nm³/min) Capacity to vent excess downstream pressure.
Connection Size 1/4 in. NPT (F) for Supply, Output, and Gauge Ports
Mounting Panel Mount (Requires a 1-1/8 inch or 29mm diameter hole)
Housing Material Zinc-Aluminum Alloy (ZA-12)
Internal Parts Brass, Buna-N, Stainless Steel, Anodized Aluminum
Standard Color Gray
Temperature Range -20° to 180°F (-29° to 82°C)
Parameter Specification
Model 26A5291X012
Product Line Fisher 667 / 667FP Actuator
Component Type Spring Cartridge (Spring Module)
Actuator Size Size 70
Spring Range 1440 - 2240 psi (on a 667 diaphragm)
Equivalent Force: Approx. 3620 - 5620 lbf (16.1 - 25.0 kN)
Action Provides the return force for spring-return actuators. The fail-safe direction (FO or FC) is determined by how the actuator is oriented on the valve.
Fail-Safe Action Enables Fail-Closed or Fail-Open operation upon air supply failure.
Standard Style Standard (Non-Fire Safe)
Material Carbon Steel Spring; Protective Epoxy Coating
Parameter Specification Notes / Details
Model 16A5376X082
Product Line Fisher 1052 NAMUR Pneumatic Actuator
Actuator Type Double-Acting (Springless) Requires air for both open & close strokes.
Action Double-Acting
Fail-Safe Mode None (Air-to-Air) Lacks a spring. Stays in last position on air failure unless paired with an external safety system.
Torque Output Approx. 413 lb-in (47 Nm) at 80 psi (5.5 bar) supply pressure. Torque is proportional to air supply pressure.
Supply Pressure Range 40 to 120 psi (2.8 to 8.3 bar) Standard operating range.
Standard Air Connection NPT 1/4"
Mounting Standard VDI/VDE 3845 (NAMUR) Standardized interface for quarter-turn valve accessories (e.g., limit switches, solenoid valves).
Mounting Style Direct to NAMUR-compliant valves; Side-mounted to Fisher 1061/1066 piston actuators for double-block-and-bleed applications.
Temperature Range Standard: -4° to 180°F (-20° to 82°C)
Low Temp.: -40° to 180°F (-40° to 82°C) (with optional seals)
Materials Body: Die-cast aluminum
Corrosion Protection: Powder-coated epoxy finish
Internal Parts: Plated for corrosion resistance.