Parameter Specification
Product Model MTL7787+
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel 2-wire transmitter isolator & power supply
Input Signal 4-20 mA from hazardous-area transmitters
Output Signal Isolated 4-20 mA (dual channels)
Power Supply 20-30 V DC (typical)
Isolation Galvanic isolation (input/output/power)
Intrinsic Safety (IS) Certification ATEX, IECEx, FM, CSA (entity parameters required for design)
Line Fault Detection Open/short circuit detection
Accuracy ±0.1% of span (typical)
Mounting DIN-rail (35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification
Product Model CMS1-7-R
Product Line Eaton CMS Rotary Isolator Switches
Rated Operational Current 32 A (at 400 V AC)
Rated Insulation Voltage 690 V AC
Number of Poles 1 Pole (1P)
Contact Configuration 1 NO (Normally Open) or 1 NC (Normally Closed)
Mechanical Life > 10,000 cycles
Protection Rating IP65 (dust-tight and water-resistant)
Mounting Panel-mounted with front seal
Operating Temperature -25°C to +55°C
Standards Compliance IEC 60947-3, UL 508
Parameter Specification
Product Model F101-PS
Product Line Eaton F-Series Safety System
Input Voltage 24 V DC (rated)
Input Voltage Range 20–30 V DC
Rated Power Output ≤50 W (system-dependent)
Efficiency >90% (typical)
Protection Features Reverse polarity, overload, short-circuit
Status Indication LED indicators (power, fault)
Mounting DIN rail (35 mm)
Operating Temperature –25°C to +55°C
Safety Standards IEC 61508, ISO 13849 (as part of safety system)
Parameter Specification
Product Model INTERGY R648
Product Line Eaton INTERGY Series UPS
Topology Double-conversion online (VFI)
Rated Power Capacity 6 kVA / 4.8 kW (at 230 V AC)
Input Voltage Range 160–276 V AC (auto-sensing)
Input Frequency Range 50/60 Hz (auto-sensing)
Output Voltage 230 V AC (±1% steady state)
Output Frequency 50/60 Hz (±0.5% in battery mode)
Battery Runtime Configurable (typical 5–30 minutes with external battery modules)
Efficiency >95% at full load
Communication Interfaces Ethernet, RS-232, USB, dry contacts
Form Factor 2U rack-mountable
Operating Temperature 0–40°C
Standards Compliance IEC 62040-3, CE, UL, RoHS
Parameter Specification
Product Model EASY400-POW
Product Line Eaton EASY400 Series Accessory
Input Voltage 100–240 V AC (50/60 Hz)
Output Voltage 24 V DC (typical for control circuits)
Rated Power ≤50 W (dependent on configuration)
Compatibility EASY400 Series Soft Starters
Protection Features Overload, short-circuit protection
Mounting Integrated with EASY400 starter or DIN rail
Operating Temperature –20°C to +60°C
Standards Compliance UL, CE, IEC/EN 60947-4-2
Parameter Specification
Product Model SEBAC00
Product Line Eaton SurgeBreak Series SPD
Rated Voltage 120/240 V AC (single-phase)
Max. Continuous Operating Voltage (Uc) 275 V AC
Nominal Discharge Current (In) 20 kA (8/20 μs)
Voltage Protection Level (Up) < 1.5 kV (at 20 kA, 8/20 μs)
Response Time < 25 ns
Connection Screw terminals
Status Indication Visual indicator (green/red)
Standards Compliance UL 1449 4th Edition, IEC 61643-11
Parameter Specification
Product Model NPR48
Product Line Eaton NPR Series Power Supply
Output Voltage 48 V DC
Output Current ~2.1 A (typical, 100W output)
Output Power 100 W (typical)
Input Voltage Range 85-264 V AC (universal input)
Efficiency >89% (typical)
Operating Temperature -25°C to +70°C
Cooling Method Convection cooling
Protections Overload, overvoltage, short-circuit
Safety Standards UL/EN/IEC 62368-1, CE marked
Parameter Specification
Product Model PFR-10
Product Line Eaton PFR Series (Power Filter Reactor)
Rated Current 10 A
Phase Configuration Single Phase
Rated Voltage Typically 480 V AC or 600 V AC (verify via datasheet)
Frequency 50/60 Hz
Inductance Tolerance ±10% (typical)
Insulation Class Class F or H (heat-resistant)
Cooling Method Air-cooled, dry-type
Mounting Method Chassis or panel mounting
Standards Compliance UL, CSA, CE (region-dependent)
Parameter Specification
Product Model PFR-5
Product Line Eaton PFR Series (Power Filter Reactor)
Rated Current 5 A
Phase Single Phase
Rated Voltage Typically 480 V AC or 600 V AC (verify via datasheet)
Frequency 50/60 Hz
Inductance Tolerance ±10% (typical)
Insulation Class Class F or H (heat-resistant)
Cooling Method Air-cooled, dry-type
Mounting Chassis or panel mounting
Standards Compliance UL, CSA, CE (region-dependent)