Model Foxboro P0916FL
Type Gauge Pressure Transmitter
Measurement Range 0-1000 psi (e.g., "16" may indicate 0-1000 psi range)
Output Signal 4-20 mA DC with HART® Protocol
Accuracy ±0.065% of span (typical for 823 series)
Power Supply 10.5-42 V DC (loop-powered)
Process Connection 1/2" NPT Female
Wetted Materials Diaphragm: 316L Stainless Steel; Seals: Viton® (FKM)
Housing Rating NEMA 4X (IP66)
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Process Temperature -40°C to +120°C (-40°F to +248°F)
Protocol HART® 7
Adjustable Turndown Up to 100:1
Stability ±0.1% of URL per year
Certifications ATEX, IECEx, SIL 2/3 (depending on configuration)
Model Foxboro ICP10-T2001E-M2L1A3T
Type Pressure Transmitter (Gauge/Absolute)
Measurement Range 0-200 psi (e.g., "T200" may indicate 0-200 psi range)
Output Signal 4-20 mA DC with HART® Protocol
Accuracy ±0.25% of span (typical for ICP10 series)
Power Supply 12-42 V DC (loop-powered)
Process Connection 1/2" NPT Female (standard)
Wetted Materials 316L Stainless Steel diaphragm and body
Housing Rating NEMA 4X (IP66)
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Process Temperature -40°C to +120°C (-40°F to +248°F)
Protocol HART® 7
Adjustable Turndown Up to 10:1
Certifications CE, RoHS (may vary by region)
Electrical Connection 1/2" NPT conduit (as indicated by suffix)
Model Foxboro IMT25-IEBTB10N-B
Type Multi-Variable Pressure Transmitter (DP, Static Pressure, Temperature)
Measurement Range Differential Pressure (DP): 0-10 inH₂O (e.g., "10N" indicates 10 inH₂O span)
Static Pressure: Up to 3600 psi (dependent on model variant)
Temperature: Integrated RTD or via external sensor
Output Signal 4-20 mA DC with HART® or FOUNDATION™ Fieldbus digital protocol
Accuracy DP: ±0.04% of span; Static Pressure: ±0.1% of URL; Flow: ±0.5% of rate (typical)
Power Supply 10.5-42 V DC (loop-powered for HART); 9-32 V DC (Fieldbus)
Process Connection 1/2" NPT or flanged (e.g., 1/4" NPT for HP/LP sides)
Wetted Materials Hastelloy C-276 diaphragm and seals (standard for corrosive environments)
Housing Rating NEMA 4X (IP66)
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Process Temperature -40°C to +120°C (-40°F to +248°F)
Protocol HART® 7 or FOUNDATION™ Fieldbus
Adjustable Turndown Up to 100:1
Certifications SIL 2/3, ATEX, IECEx, CE
Special Features Integrated flow computation, diagnostics, temperature compensation
Model Foxboro IMT25-PEATB10N-B
Type Multi-Variable Pressure Transmitter (DP, Static Pressure, Temperature)
Measurement Range Differential Pressure (DP): 0-10 inH₂O (e.g., "10N" indicates 10 inH₂O span)
Static Pressure: Up to 3600 psi (dependent on model variant)
Temperature: Integrated RTD or via external sensor
Output Signal 4-20 mA DC with HART® or FOUNDATION™ Fieldbus digital protocol
Accuracy DP: ±0.04% of span; Static Pressure: ±0.1% of URL; Flow: ±0.5% of rate (typical)
Power Supply 10.5-42 V DC (loop-powered for HART); 9-32 V DC (Fieldbus)
Process Connection 1/2" NPT or flanged (e.g., 1/4" NPT for HP/LP sides)
Wetted Materials Hastelloy C-276 diaphragm and seals (standard for corrosive environments)
Housing Rating NEMA 4X (IP66)
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Process Temperature -40°C to +120°C (-40°F to +248°F)
Protocol HART® 7 or FOUNDATION™ Fieldbus
Adjustable Turndown Up to 100:1
Certifications SIL 2/3, ATEX, IECEx, CE
Special Features Integrated flow computation, diagnostics, temperature compensation
Model Foxboro BY3R873RS-BTWFGZ
Type Pressure Transmitter (e.g., Gauge/Absolute/Differential)
Measurement Range Customized (e.g., 0-1000 psi or other; "BTW" may indicate range code)
Output Signal 4-20 mA DC with HART® Protocol
Accuracy ±0.065% to ±0.1% of span (typical for 873 series)
Power Supply 10.5-42 V DC (loop-powered)
Process Connection 1/2" NPT or flanged (material: stainless steel or alloy)
Wetted Materials Likely 316L Stainless Steel or Hastelloy (e.g., "FGZ" may specify materials)
Housing Rating NEMA 4X (IP66)
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Process Temperature -40°C to +120°C (-40°F to +248°F)
Protocol HART® 7
Certifications ATEX, IECEx, SIL 2/3 (depending on configuration)
Calibration Factory calibrated to customer specifications
Model Foxboro HHT-AAEFNB Style-B
Type Handheld Terminal (HHT) / Configurator
Compatibility Foxboro field instruments (e.g., pressure/flow transmitters)
Communication Protocols HART® (primary), potentially FOUNDATION™ Fieldbus or other protocols
Display LCD screen (likely backlit for low-light environments)
Keypad Sealed, ruggedized keys for use in harsh conditions
Power Supply Rechargeable battery (e.g., Li-ion or NiMH) with AC adapter
Battery Life 8-12 hours (typical per charge)
Connectivity Electrical connections: 4-20 mA loop integration via test leads or connectors
Operating Temperature -10°C to 50°C (14°F to 122°F) (field-use range)
Enclosure Rating IP54 or higher (dust and water resistant)
Software Features Device configuration, calibration, diagnostics, loop tests, data logging
Certifications ATEX, IECEx (if rated for hazardous areas)
Dimensions & Weight Compact and lightweight for portability (e.g., ~200-300g)
Model Foxboro FEM100
Type Fieldbus Electronic Module (FOUNDATION™ Fieldbus H1)
Compatibility Foxboro I/A Series DCS (requires FMM chassis or compatible fieldbase)
Protocol Support FOUNDATION™ Fieldbus H1 (IEC 61158-2)
Number of Channels Typically 1 or 2 Fieldbus segments per module (varies by configuration)
Power Supply 24 V DC (via chassis or external fieldbus power supply)
Segment Power Provides conditioned power to Fieldbus segments (e.g., 19-23 V DC)
Isolation 1500 V AC (channel-to-channel and channel-to-system)
Communication Speed 31.25 kbit/s (standard Fieldbus H1 rate)
Max Devices per Segment Up to 16 Fieldbus devices per segment
Operating Temperature 0°C to 60°C (32°F to 140°F)
Redundancy Support Yes (optional redundant configuration)
Diagnostics LED status indicators for power, communication, and faults
Certifications ATEX, IECEx, CE (depending on installation and region)
Model Foxboro IMT25-PEATB10N-B
Type Multi-Variable Pressure Transmitter (Pressure/DP/Flow)
Measurement Range Differential Pressure (DP): 0-10 inH₂O to 0-2000 psi (varies by code)
Static Pressure: Up to 3600 psi (depending on model)
Output Signal 4-20 mA DC with HART® or FOUNDATION™ Fieldbus digital protocol
Accuracy DP: ±0.04% of span (typical); Static Pressure: ±0.1% of URL
Power Supply 10.5-42 V DC (loop-powered for HART); 9-32 V DC (Fieldbus)
Process Connection 1/2" NPT or flanged (e.g., 1/4" NPT for HP/LP sides)
Wetted Materials Stainless Steel (316L), Hastelloy C-276, or other alloys (depending on variant)
Housing Rating NEMA 4X (IP66)
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Process Temperature -40°C to +120°C (-40°F to +248°F)
Protocol HART® 7 or FOUNDATION™ Fieldbus
Adjustable Turndown Up to 100:1
Certifications SIL 2/3, ATEX, IECEx, CE
Special Features Integrated flow computation, diagnostics, and temperature compensation
Model Foxboro P0903CW Rev-0C
Type Pressure Transmitter (Gauge/Absolute)
Measurement Range Likely 0-100 psi or similar (e.g., "03" in P0903 may indicate range code)
Output Signal 4-20 mA DC with HART® Protocol
Accuracy ±0.065% to ±0.1% of span (typical for Foxboro transmitters)
Power Supply 10.5-42 V DC (loop-powered)
Process Connection 1/2" NPT Female or Flanged (material: Hastelloy C-276)
Wetted Materials Diaphragm: Hastelloy C-276; Seals: Viton® or PTFE (corrosion-resistant)
Housing Rating NEMA 4X (IP66)
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Process Temperature -40°C to +120°C (-40°F to +248°F)
Adjustable Turndown Up to 100:1
Protocol HART® 7
Certifications ATEX, IECEx, SIL 2/3 (depending on configuration)
Revision Rev-0C (may include firmware updates or minor hardware changes)
Model Foxboro FBM216
Module Type Discrete Output (DO) - Sourcing Type
Number of Channels 16
Output Type Sourcing (24-48 V DC typical), Solid-State
Output Voltage Range 20-60 V DC (depending on field supply)
Current Rating 0.5 A per channel (max), with group current limits
Load Compatibility Solenoids, relays, motor starters, indicator lamps
System Compatibility Foxboro I/A Series DCS (requires FBM200 series fieldbase)
Update Rate Millisecond response time
Isolation Channel-to-channel and channel-to-bus isolation (500 V AC minimum)
Power Supply Fieldbase-powered (5 V DC internal); field device power requires external supply
Diagnostics Per-channel status LEDs, module health monitoring (OK/FAIL)
Redundancy Support Yes (1:1 redundancy configuration)
Connections Removable screw terminal block on fieldbase
Operating Temperature 0°C to 60°C (32°F to 140°F)
Enclosure Designed for installation in FBM fieldbase (rack-mounted)
Certifications Designed for industrial environments (CE, ATEX depending on installation)