Products
Products
home
honeywell
FC-RUSIO-3224
honeywell
900P01-0301=2
Honeywell 900P01-0301=2
Function: Redundancy-Ready CPU Module for HC900 Process Control Systems.

Core Role:

Primary processor for executing control logic (PID, sequencing) in HC900 racks.

Supports hot-swap N+1 redundancy for fail-safe operation.

Key Specs:

I/O Capacity: Up to 16 modules (256 points).

Communications: Modbus TCP (Ethernet), Modbus RTU/ASCII (RS-232/485).

Environment: -40°C to +70°C industrial rating.

Integration:

Requires HC900 C70/C75 chassis; compatible with analog/digital I/O modules.

More details >> Request a Quote >>
honeywell
900C75-0460=2
Honeywell 900C75-0460=2
Function: 120W Power Supply Module for HC900 Process Control Systems.

Key Features:

Input: 85–265 VAC (50/60 Hz) or 88–300 VDC (universal).

Output: 24 VDC, 5A (regulated, 120W max).

Redundancy: Supports N+1 backup with identical modules.

Protections: Short-circuit, over-voltage, and thermal shutdown.

Compatibility:

Designed for HC900 C50/C70/C75 racks.

Robust Design:

Operates in -40°C to +70°C harsh environments.

Certifications: UL, CE, ATEX Zone 2.

More details >> Request a Quote >>
honeywell
HC900RR0-0101
Honeywell HC900RR0-0101
Function: CPU Module for Honeywell’s HC900 Hybrid Process Control System.

Core Role:

Acts as the central processor for HC900 racks, executing control logic (PID, sequencing, etc.).

Supports 16 I/O modules (max 256 points) for analog/digital signals.

Key Features:

Communications: Ethernet (Modbus TCP), RS-232/485 (Modbus RTU/ASCII), embedded web server.

Robust Operation: -40°C to +70°C industrial temperature range.

Power: 24 VDC (±10%).

More details >> Request a Quote >>
honeywell
XF524A
Honeywell XF524A
Function: Dual-Circuit Monitor Module for conventional fire alarm systems.

Key Features:

Monitors two independent dry-contact devices (e.g., flow switches, tamper switches, door holders).

Input Voltage: 15–32 VDC (regulated).

Low Power: Standby ≤1.5 mA; alarm ≤6 mA per circuit.

Wiring: Class A (Style Z) or Class B (Style Y) supervision.

More details >> Request a Quote >>
honeywell
XF521A
Honeywell XF521A
Function: Dry Contact Monitor Module for conventional fire alarm systems.

Key Features:

Supervises dry-contact devices (e.g., door holders, sprinkler flow switches, HVAC shutdowns).

Input Voltage: 15–32 VDC (regulated).

Low Power: Standby current ≤1.5 mA; alarm current ≤6 mA.

Wiring Styles: Supports Class A (Style Z) or Class B (Style Y) supervision.

Compatibility:

Works with Notifier® fire panels (e.g., NFS2-640, AFP-1010/AFP-4000).

Certifications: UL 864, ULC, CE.

More details >> Request a Quote >>
honeywell
XC5010C
Honeywell XC5010C
Function: Conventional Fire Alarm Zone Module for expanding detection capacity in fire systems.

Key Features:

Input Voltage: 15–32 VDC (regulated power).

Load Capacity: Supports 50 detectors + accessories (e.g., manual call points, monitors).

Compatibility: Integrates with Notifier® NFS2-3030/C, AFP-1010, and similar panels.

Wiring: Class A (Style D) or Class B (Style B) configurations.

Environmental:

Operating Temp: -10°C to +55°C (14°F to 131°F).

Certifications: UL 864, ULC, CE.

More details >> Request a Quote >>
honeywell
51454220-176
Honeywell 51454220-176
Function: 16-channel Digital Input Module for Honeywell Experion® PKS/LX control systems.

Key Features:

Isolated Inputs: 24 VDC (sink/source configurable) with 1500 VAC channel isolation.

High-Speed: ≤5 ms response time.

Robust Design: Operates in -40°C to +70°C harsh environments.

Certifications: ATEX/IECEx, SIL 2 (IEC 61508).

Integration:

Mounts in Experion LX I/O chassis; interfaces with C300 controllers.

Typical Use:

Monitoring switches/sensors in oil & gas, chemical, or power plants.

More details >> Request a Quote >>
honeywell
SPXCDXSB1SS
Danfoss SPXCDXSB1SS
Function: Electronic Expansion Valve (EEV) for precise refrigerant flow control in cooling systems.

Key Features:

Refrigerants: Compatible with R134a, R404A, R410A, R407C, R507.

Robust Operation: Withstands -40°C to +125°C and 42 bar (608 psi).

Control: 12 VDC powered; accepts PWM or 0–10 VDC signals.

Connection: 1/2" SAE flare.

More details >> Request a Quote >>
honeywell
jace91250
Honeywell JACE-91250 Technical Specifications
General Information
Manufacturer: Honeywell (Tridium Niagara Framework)

Model: JACE-91250

Type: Advanced Building Automation Controller

Primary Use: HVAC, lighting, security, and energy management integration

Hardware Specifications
Processor & Memory
CPU: Quad-core ARM Cortex-A9 @ 1.0 GHz

RAM: 2 GB DDR3

Flash Storage: 8 GB eMMC (expandable via microSD)

Communication Ports
Ethernet: 2× 10/100/1000 Mbps (RJ45)

Serial Ports: 2× RS-485 (for BACnet MS/TP, Modbus RTU, etc.)

USB: 2× USB 2.0 (for configuration/drivers)

Wireless: Optional Wi-Fi/4G LTE module

Expansion & I/O
Slot for Expansion Modules: Supports Honeywell I/O modules (e.g., analog/digital)

Max Supported Points: ~100,000 (software-dependent)

Software & Protocols
Operating System: Embedded Linux (Niagara 4 Framework)

Supported Protocols:

BACnet (IP & MS/TP)

Modbus (TCP/RTU)

LonWorks (optional)

OPC UA/DA

MQTT (for IoT/cloud connectivity)

SNMP (network monitoring)

Performance & Capacity
Concurrent Users: Supports 50+ simultaneous connections

Alarm Capacity: 50,000+ alarms

Database Storage: 5+ years of trend data (configurable)

Power & Environmental
Power Supply: 24V AC/DC or PoE+ (Power over Ethernet)

Power Consumption: 15W (typical)

Operating Temperature: -40°C to +70°C (-40°F to +158°F)

Humidity: 10–90% non-condensing

Ingress Protection: IP30 (indoor use)

Certifications & Compliance
UL 916 (Energy Management)

CE, FCC, RoHS

BACnet BTL Listed

Cybersecurity: TLS 1.2/1.3, role-based access

Key Features
✔ High-performance edge controller for large-scale BMS
✔ Multi-protocol integration (legacy & modern systems)
✔ Cybersecurity hardened (SSL encryption, secure boot)
✔ Cloud-ready (Niagara Edge-to-Cloud)

Typical Applications:

Smart buildings

Data centers

Industrial automation

More details >> Request a Quote >>