Parameter Specification
Product Model MTL7706+
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification
Product Model MTL7743
Product Line Eaton MTL Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated 4-20 mA DC signal.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification
Product Model MTL7765AC
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Likely 100-240V AC (Inferred from "AC" suffix. MUST be verified from datasheet).
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, etc.
Parameter Specification
Product Model MTL788+
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Parameter Specification
Product Model MTL7760AC
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply AC Input (e.g., 100-240V AC, specific range MUST be verified from datasheet).
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, etc.
Parameter Specification
Product Model PFR-W-30
Product Line Eaton PFR
Rated Current 30 A
Phase Single Phase
Rated Voltage Typically 480 V AC or 600 V AC
Frequency 50/60 Hz
Inductance Tolerance Typically ±10%
Insulation Class Typically Class F or H
Cooling Method Air-cooled, dry-type
Mounting Suitable for chassis or panel mounting
Standards Compliance UL, CSA, CE
Parameter Specification / Inference
Product Model T0-2-15679/I1/SVB
Product Line Eaton T0 Power Contactor
Rated Operational Current (Ie) Typically up to ~25 A at AC-3, 400V
Rated Operational Voltage (Ue) Up to 690 V AC
Number of Main Poles 2
Coil Voltage 230 V AC, 50/60 Hz
Auxiliary Contacts 1 NO (Normally Open)
Mounting Style Base Mounting with Screw Terminals (SVB)
Electrical Life > 1 million operations (at rated load)
Mechanical Life > 10 million operations
Standards Compliance IEC 60947-4-1, UL 508
Parameter Specification
Product Model MTL5541S
Product Line Eaton MTL5500+ Series Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated 4-20 mA DC signal.
Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher)
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (MUST be verified from datasheet):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm), Slimline (S) design for high density.
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, etc.
Parameter Specification / Inference
Product Catalog Number 13104RQD07
Product Series 13104 (Heavy-Duty Oiltight Limit Switch)
Operator Type Lever Arm, Rotary (inferred from RQ)
Contact Configuration 1 NO (Normally Open) (inferred from D07)
Rated Operational Current Typically 10 A @ 600 V AC (Common for these switches)
Electrical Life Typically 1-2 million operations (at rated load)
Mechanical Life Typically 10+ million operations
Enclosure Rating NEMA 4, 4X, 13; IP67 (Oiltight, Dust-tight, Water-resistant)
Housing Material Typically Zinc Die Cast
Actuator Material Steel or Thermoplastic roller
Terminal Type Screw terminals
Standards Compliance UL Listed, cULus, CE
Parameter Specification / Inference
Product Model LSM-11/RLA
Product Line Eaton Limit Switches
Product Type Heavy-Duty Precision Limit Switch
Contact Configuration 1 NO + 1 NC
Actuator Type Rotating Lever Arm, Adjustable (RLA)
Rated Operational Current Typically 10 A @ 600 V AC
Electrical Life > 1 million operations
Mechanical Life > 10 million operations
Enclosure Rating NEMA 4, 4X, 13; IP67
Housing Material Typically Zinc Die Cast
Terminal Type Screw terminals
Standards Compliance UL Listed, cULus, CE