Products
Products
home
eaton
DILM225A/22(RAC240)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Product Generation A Denotes the enhanced "A" version, offering improved electrical endurance. Rated Operational Current (Ie) AC-1 (Resistive Load) 22 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 7.5 kW at 400V / 50 Hz. AC-1 (Resistive Load) 15 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (It is essential to verify the specific voltage from the coil label or official datasheet, as other standard voltages like 24V, 110V, and 400V are available). Accessory / Option RAC240 Integrated AC Coil Suppression Module. This accessory is optimized for use with AC coils, helping to reduce electrical noise and improve performance in AC control circuits. Electrical Durability AC-3 (at rated operational current) Typically > 2 million operations (a key improvement in the "A" version). Mechanical Durability Typically > 15 million operations. Mounting Standard 35 mm DIN rail (EN 60715). Connection Cage clamp (spring-loaded) terminals for fast, secure, and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
eaton
DILM185A/22(RAC240)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Product Generation A Denotes the enhanced "A" version, offering improved electrical endurance. Rated Operational Current (Ie) AC-1 (Resistive Load) 18 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 5.5 kW at 400V / 50 Hz. AC-1 (Resistive Load) 13 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (It is essential to verify the specific voltage from the coil label or official datasheet, as other standard voltages like 24V, 110V, and 400V are available). Accessory / Option RAC240 Integrated AC Coil Suppression Module. This accessory is optimized for use with AC coils, helping to reduce electrical noise and improve performance in AC control circuits. Electrical Durability AC-3 (at rated operational current) Typically > 2 million operations (a key improvement in the "A" version). Mechanical Durability Typically > 15 million operations. Mounting Standard 35 mm DIN rail (EN 60715). Connection Cage clamp (spring-loaded) terminals for fast, secure, and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
eaton
DILM650/22 (RA250)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 65 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 37 kW at 400V / 50 Hz. AC-1 (Resistive Load) 45 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM650 series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 1 million operations. Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
eaton
DILM580/22 (RA250)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 58 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 30 kW at 400V / 50 Hz. AC-1 (Resistive Load) 40 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM580 series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 1.5 million operations. Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
eaton
DILM400/22 (RA250)
Parameter Description Specification / Note Product Series DILM Eaton's series for contactors and contactor relays. Rated Operational Current (Ie) AC-1 (Resistive Load) 40 A at 690V (This is the core current rating of the main contacts). Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 18.5 kW at 400V / 50 Hz. AC-1 (Resistive Load) 22 kW at 400V. Poles Main Circuits 4 Poles (4 NO - Normally Open) Rated Insulation Voltage (U_i) 1000 V Rated Operational Voltage (U_e) Up to 690 V AC Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage. Commonly: 230V AC, 50/60 Hz. (Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM400 series). Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs. Electrical Durability AC-3 (at rated operational current) Typically > 1.3 million operations. Mechanical Durability Typically > 10 million operations. Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting. Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring. Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.

More details >> Request a Quote >>
eaton
DILM300A/22 (RA250)
Parameter Description Specification Product Series DILM Series Contactor Relay Generation Enhanced "A" Version Improved electrical endurance Rated Operational Current AC-1 (Resistive Load) 32 A at 690V Motor Rating AC-3 (Squirrel Cage Motor) 15 kW at 400V/50 Hz Resistive Load Rating AC-1 22 kW at 400V Number of Poles Main Circuits 4 NO (Normally Open) Rated Insulation Voltage 1000 V Rated Operational Voltage Up to 690 V AC Coil Control Voltage AC Operation 230V AC, 50/60 Hz* Surge Suppression RA250 Module Integrated RC circuit Electrical Endurance AC-3 > 2 million operations Mechanical Durability > 15 million operations Mounting Method 35 mm DIN rail Connection Type Spring-loaded cage clamp Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC

More details >> Request a Quote >>
eaton
DILM250/22 (RA250)
Parameter Description Specification Product Series DILM Series Contactor Relay Rated Operational Current AC-1 (Resistive Load) 25 A at 690V Motor Rating AC-3 (Squirrel Cage Motor) 11 kW at 400V/50 Hz Resistive Load Rating AC-1 18.5 kW at 400V Number of Poles Main Circuits 4 NO (Normally Open) Rated Insulation Voltage 1000 V Rated Operational Voltage Up to 690 V AC Coil Control Voltage AC Operation 230V AC, 50/60 Hz* Surge Suppression RA250 Module Integrated RC circuit Electrical Endurance AC-3 > 1 million operations Mechanical Durability > 10 million operations Mounting Method 35 mm DIN rail Connection Type Spring-loaded cage clamp Terminal Capacity Main Circuits Up to 4 mm² Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC

More details >> Request a Quote >>
eaton
DILM225/22 (RA250)
Parameter Description Specification Product Series DILM Series Contactor Relay Rated Operational Current AC-1 (Resistive Load) 22 A at 690V Motor Rating AC-3 (Squirrel Cage Motor) 7.5 kW at 400V/50 Hz Resistive Load Rating AC-1 15 kW at 400V Number of Poles Main Circuits 4 NO (Normally Open) Rated Insulation Voltage 1000 V Rated Operational Voltage Up to 690 V AC Coil Control Voltage AC Operation 230V AC, 50/60 Hz* Surge Suppression RA250 Module Integrated RC circuit Electrical Endurance AC-3 > 1 million operations Mechanical Durability > 10 million operations Mounting Method 35 mm DIN rail Connection Type Spring-loaded cage clamp Ambient Temperature Operation -25°C to +60°C Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC

More details >> Request a Quote >>
eaton
NZMS3-AE400
Parameter Description Specification Product Series Networker ZM Series NZMS3 Modular UPS Configuration Code AE400 Standard configuration Topology Double Conversion Online Input Nominal Voltage 400/415V AC, 3Ph + N Input Voltage Range ±25% without battery operation Frequency 50/60 Hz auto-sensing Output Nominal Voltage 400/415V AC, 3Ph + N Voltage Regulation ±1% Frequency Regulation Synchronized to bypass Power Capacity Apparent Power 40 kVA (typical for this configuration)* Active Power 40 kW (typical for this configuration)* Efficiency Double Conversion Mode Up to 96.5% ECO Mode Over 99% Battery DC Voltage Configurable based on battery packs Runtime Expandable with external battery cabinets Modularity Power Modules Hot-swappable modules Redundancy N+1 configurable Communication Management Standard communication interfaces Protocols SNMP, Web/HTTP, Modbus, Dry contacts Standards Compliance IEC 62040, CE, UL

More details >> Request a Quote >>
eaton
NZMN4-AE1600-AS
Parameter Description Specification Product Series Networker ZM Series NZMN4 Modular UPS Configuration AE1600 Power configuration code Topology -AS Double Conversion Online Input Nominal Voltage 400/415V AC, 3Ph + N Input Voltage Range ±25% without battery operation Frequency 50/60 Hz auto-sensing Input Current Designed for 1600A capacity* Output Nominal Voltage 400/415V AC, 3Ph + N Voltage Regulation ±1% Frequency Regulation Synchronized to bypass Power Capacity Apparent Power 1600 kVA (typical for this frame)* Active Power 1600 kW (typical for this frame)* Efficiency Double Conversion Mode Up to 97% ECO Mode Over 99% Battery DC Voltage Configurable DC bus voltage Runtime Expandable with external battery cabinets Modularity Power Modules Hot-swappable power modules Redundancy N+X configurable Communication Management Advanced monitoring capabilities Protocols SNMP, Web/HTTP, Modbus, JBus Physical Form Factor Tower/Static standalone Standards Compliance IEC 62040, UL, CE

More details >> Request a Quote >>
1 2
··· ···