Parameter Description Specification / Note
Product Series DILM Eaton's series for contactors and contactor relays.
Product Generation A Denotes the enhanced "A" version, offering improved electrical endurance.
Rated Operational Current (Ie) AC-1 (Resistive Load) 22 A at 690V (This is the core current rating of the main contacts).
Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 7.5 kW at 400V / 50 Hz.
AC-1 (Resistive Load) 15 kW at 400V.
Poles Main Circuits 4 Poles (4 NO - Normally Open)
Rated Insulation Voltage (U_i) 1000 V
Rated Operational Voltage (U_e) Up to 690 V AC
Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage.
Commonly: 230V AC, 50/60 Hz.
(It is essential to verify the specific voltage from the coil label or official datasheet, as other standard voltages like 24V, 110V, and 400V are available).
Accessory / Option RAC240 Integrated AC Coil Suppression Module. This accessory is optimized for use with AC coils, helping to reduce electrical noise and improve performance in AC control circuits.
Electrical Durability AC-3 (at rated operational current) Typically > 2 million operations (a key improvement in the "A" version).
Mechanical Durability Typically > 15 million operations.
Mounting Standard 35 mm DIN rail (EN 60715).
Connection Cage clamp (spring-loaded) terminals for fast, secure, and tool-free wiring.
Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.
Parameter Description Specification / Note
Product Series DILM Eaton's series for contactors and contactor relays.
Product Generation A Denotes the enhanced "A" version, offering improved electrical endurance.
Rated Operational Current (Ie) AC-1 (Resistive Load) 18 A at 690V (This is the core current rating of the main contacts).
Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 5.5 kW at 400V / 50 Hz.
AC-1 (Resistive Load) 13 kW at 400V.
Poles Main Circuits 4 Poles (4 NO - Normally Open)
Rated Insulation Voltage (U_i) 1000 V
Rated Operational Voltage (U_e) Up to 690 V AC
Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage.
Commonly: 230V AC, 50/60 Hz.
(It is essential to verify the specific voltage from the coil label or official datasheet, as other standard voltages like 24V, 110V, and 400V are available).
Accessory / Option RAC240 Integrated AC Coil Suppression Module. This accessory is optimized for use with AC coils, helping to reduce electrical noise and improve performance in AC control circuits.
Electrical Durability AC-3 (at rated operational current) Typically > 2 million operations (a key improvement in the "A" version).
Mechanical Durability Typically > 15 million operations.
Mounting Standard 35 mm DIN rail (EN 60715).
Connection Cage clamp (spring-loaded) terminals for fast, secure, and tool-free wiring.
Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.
Parameter Description Specification / Note
Product Series DILM Eaton's series for contactors and contactor relays.
Rated Operational Current (Ie) AC-1 (Resistive Load) 65 A at 690V (This is the core current rating of the main contacts).
Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 37 kW at 400V / 50 Hz.
AC-1 (Resistive Load) 45 kW at 400V.
Poles Main Circuits 4 Poles (4 NO - Normally Open)
Rated Insulation Voltage (U_i) 1000 V
Rated Operational Voltage (U_e) Up to 690 V AC
Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage.
Commonly: 230V AC, 50/60 Hz.
(Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM650 series).
Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs.
Electrical Durability AC-3 (at rated operational current) Typically > 1 million operations.
Mechanical Durability Typically > 10 million operations.
Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting.
Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring.
Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.
Parameter Description Specification / Note
Product Series DILM Eaton's series for contactors and contactor relays.
Rated Operational Current (Ie) AC-1 (Resistive Load) 58 A at 690V (This is the core current rating of the main contacts).
Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 30 kW at 400V / 50 Hz.
AC-1 (Resistive Load) 40 kW at 400V.
Poles Main Circuits 4 Poles (4 NO - Normally Open)
Rated Insulation Voltage (U_i) 1000 V
Rated Operational Voltage (U_e) Up to 690 V AC
Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage.
Commonly: 230V AC, 50/60 Hz.
(Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM580 series).
Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs.
Electrical Durability AC-3 (at rated operational current) Typically > 1.5 million operations.
Mechanical Durability Typically > 10 million operations.
Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting.
Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring.
Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.
Parameter Description Specification / Note
Product Series DILM Eaton's series for contactors and contactor relays.
Rated Operational Current (Ie) AC-1 (Resistive Load) 40 A at 690V (This is the core current rating of the main contacts).
Rated Operational Power (P_e) AC-3 (Squirrel Cage Motor) 18.5 kW at 400V / 50 Hz.
AC-1 (Resistive Load) 22 kW at 400V.
Poles Main Circuits 4 Poles (4 NO - Normally Open)
Rated Insulation Voltage (U_i) 1000 V
Rated Operational Voltage (U_e) Up to 690 V AC
Coil Control Voltage The "22" in the part number indicates a specific AC coil voltage.
Commonly: 230V AC, 50/60 Hz.
(Always verify the specific voltage from the coil label or datasheet, as other voltages like 24V, 110V, 400V, etc., are available in the DILM400 series).
Accessory / Option RA250 Integrated RC Surge Suppression Module. This built-in resistor-capacitor network limits voltage peaks generated when the coil is de-energized, protecting sensitive control devices like PLCs.
Electrical Durability AC-3 (at rated operational current) Typically > 1.3 million operations.
Mechanical Durability Typically > 10 million operations.
Mounting Standard 35 mm DIN rail (EN 60715) or screw mounting.
Connection Cage clamp (spring-loaded) terminals for both power and control circuits, allowing for fast and tool-free wiring.
Standards & Approvals CE, cULus (UL 508), CCC, IEC/EN 60947-4-1, etc.
Parameter Description Specification
Product Series DILM Series Contactor Relay
Generation Enhanced "A" Version Improved electrical endurance
Rated Operational Current AC-1 (Resistive Load) 32 A at 690V
Motor Rating AC-3 (Squirrel Cage Motor) 15 kW at 400V/50 Hz
Resistive Load Rating AC-1 22 kW at 400V
Number of Poles Main Circuits 4 NO (Normally Open)
Rated Insulation Voltage 1000 V
Rated Operational Voltage Up to 690 V AC
Coil Control Voltage AC Operation 230V AC, 50/60 Hz*
Surge Suppression RA250 Module Integrated RC circuit
Electrical Endurance AC-3 > 2 million operations
Mechanical Durability > 15 million operations
Mounting Method 35 mm DIN rail
Connection Type Spring-loaded cage clamp
Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC
Parameter Description Specification
Product Series DILM Series Contactor Relay
Rated Operational Current AC-1 (Resistive Load) 25 A at 690V
Motor Rating AC-3 (Squirrel Cage Motor) 11 kW at 400V/50 Hz
Resistive Load Rating AC-1 18.5 kW at 400V
Number of Poles Main Circuits 4 NO (Normally Open)
Rated Insulation Voltage 1000 V
Rated Operational Voltage Up to 690 V AC
Coil Control Voltage AC Operation 230V AC, 50/60 Hz*
Surge Suppression RA250 Module Integrated RC circuit
Electrical Endurance AC-3 > 1 million operations
Mechanical Durability > 10 million operations
Mounting Method 35 mm DIN rail
Connection Type Spring-loaded cage clamp
Terminal Capacity Main Circuits Up to 4 mm²
Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC
Parameter Description Specification
Product Series DILM Series Contactor Relay
Rated Operational Current AC-1 (Resistive Load) 22 A at 690V
Motor Rating AC-3 (Squirrel Cage Motor) 7.5 kW at 400V/50 Hz
Resistive Load Rating AC-1 15 kW at 400V
Number of Poles Main Circuits 4 NO (Normally Open)
Rated Insulation Voltage 1000 V
Rated Operational Voltage Up to 690 V AC
Coil Control Voltage AC Operation 230V AC, 50/60 Hz*
Surge Suppression RA250 Module Integrated RC circuit
Electrical Endurance AC-3 > 1 million operations
Mechanical Durability > 10 million operations
Mounting Method 35 mm DIN rail
Connection Type Spring-loaded cage clamp
Ambient Temperature Operation -25°C to +60°C
Standards & Approvals IEC/EN 60947-4-1, UL 508, CE, CCC
Parameter Description Specification
Product Series Networker ZM Series NZMS3 Modular UPS
Configuration Code AE400 Standard configuration
Topology Double Conversion Online
Input Nominal Voltage 400/415V AC, 3Ph + N
Input Voltage Range ±25% without battery operation
Frequency 50/60 Hz auto-sensing
Output Nominal Voltage 400/415V AC, 3Ph + N
Voltage Regulation ±1%
Frequency Regulation Synchronized to bypass
Power Capacity Apparent Power 40 kVA (typical for this configuration)*
Active Power 40 kW (typical for this configuration)*
Efficiency Double Conversion Mode Up to 96.5%
ECO Mode Over 99%
Battery DC Voltage Configurable based on battery packs
Runtime Expandable with external battery cabinets
Modularity Power Modules Hot-swappable modules
Redundancy N+1 configurable
Communication Management Standard communication interfaces
Protocols SNMP, Web/HTTP, Modbus, Dry contacts
Standards Compliance IEC 62040, CE, UL
Parameter Description Specification
Product Series Networker ZM Series NZMN4 Modular UPS
Configuration AE1600 Power configuration code
Topology -AS Double Conversion Online
Input Nominal Voltage 400/415V AC, 3Ph + N
Input Voltage Range ±25% without battery operation
Frequency 50/60 Hz auto-sensing
Input Current Designed for 1600A capacity*
Output Nominal Voltage 400/415V AC, 3Ph + N
Voltage Regulation ±1%
Frequency Regulation Synchronized to bypass
Power Capacity Apparent Power 1600 kVA (typical for this frame)*
Active Power 1600 kW (typical for this frame)*
Efficiency Double Conversion Mode Up to 97%
ECO Mode Over 99%
Battery DC Voltage Configurable DC bus voltage
Runtime Expandable with external battery cabinets
Modularity Power Modules Hot-swappable power modules
Redundancy N+X configurable
Communication Management Advanced monitoring capabilities
Protocols SNMP, Web/HTTP, Modbus, JBus
Physical Form Factor Tower/Static standalone
Standards Compliance IEC 62040, UL, CE