Technical Parameters
Parameter Specification
Product Model XC-CPU101-C256K
Product Family Eaton XC-100 Programmable Logic Controller (PLC)
Type Compact CPU Module with Integrated I/O
User Program Memory 256 KB
Data Memory 64 KB (Typical value for this family)
Integrated I/O - 14x Digital Inputs (24 V DC Sink/Source)
- 10x Digital Outputs (Relay, 2 A)
Program Execution Speed ~0.15 µs per binary instruction (Typical)
Communication Ports - 1x RS-232 (COM1) for programming and HMI
- 1x RS-485 (COM2) for networking (Modbus RTU, etc.)
Expansion Capability Supports connection of up to 7 expansion I/O modules (XC-200 series)
Real-Time Clock (RTC) Yes (With battery backup for time retention)
Programming Software Eaton XV-103 (SoMachine Basic / EcoStruxure Machine Basic)
Programming Languages Ladder Diagram (LD), Function Block Diagram (FBD), Instruction List (IL)
Supply Voltage 24 V DC (Typically via the base connector)
Physical Design Modular, DIN-rail mountable
Technical Parameters
Parameter Specification
Product Model XNE-16DO-24VDC-0.5A-P
Product Family Eaton XN System (Electronic Module)
Module Type Digital Output Module
Number of Channels 16
Output Type Sourcing (PNP)
Output Voltage 24 V DC (Nominal)
Load Current per Channel 0.5 A (Maximum)
Total Module Current 4 A (Maximum, sum of all channels)
Short-Circuit Protection Yes (Per channel, electronically)
Load Type Resistive, Inductive, Lamp Load
Isolation Channel-to-Bus: Yes (Optically isolated)
Connection Method Removable screw terminal block
Module Power Supply 24 V DC (via the XN system base or terminal block)
Status Indicators - PWR (Power): Green LED
- SF (System Fault): Red LED
- CHx (Channel Status): Green LED per channel
IP Rating IP20 (for installation inside a control cabinet)
Mounting On an XN system base unit, mounted on a standard 35 mm DIN rail
Operating Temperature -25 °C to +60 °C (-13 °F to 140 °F)
Standards & Certifications CE, UL, cULus, RoHS compliant
Technical Parameters
Parameter Specification
Product Model XC-CPU201-EC256K-8DI-6DO
Product Family Eaton XC-200 Programmable Logic Controller (PLC)
Type Compact CPU Module with Integrated I/O and Ethernet
User Program Memory 256 KB
Data Memory 128 KB
Integrated I/O - 8x Digital Inputs (24 V DC, Sink/Source)
- 6x Digital Outputs (24 V DC, Sourcing (PNP), 0.5 A)
Program Execution Speed ~0.04 µs per binary instruction (Typical, faster than XC-100 series)
Communication Ports - 1x Ethernet (RJ45) for programming, HMI, and PLC-to-PLC communication
- 1x RS-485 for networking (Modbus RTU, etc.)
Ethernet Protocol MODBUS TCP
Expansion Capability Supports connection of up to 7 expansion I/O modules (XC-200 series)
Real-Time Clock (RTC) Yes
Programming Software EcoStruxure Machine Expert - Basic (formerly SoMachine Basic)
Programming Languages Ladder Diagram (LD), Function Block Diagram (FBD), Instruction List (IL)
Supply Voltage 24 V DC
Physical Design Modular, DIN-rail mountable
Technical Parameters
Parameter Specification
Product Model EASY-E4-AC-12RC1
Product Family Eaton EASY-E4 Controller
Type Micro-PLC (Programmable Logic Controller)
Supply Voltage 100 - 240 V AC (Wide Range)
Integrated I/O Total: 20 I/O Points
- 12x Digital Inputs (24 V DC, Sink/Source)
- 8x Relay Outputs:
• 6x Changeover Contacts (CO)
• 2x Normally Open Contacts (NO)
Relay Contact Rating - 6A @ 250V AC (for CO contacts)
- 2A @ 250V AC (for NO contacts)
Program Memory Typically ~4 KB (for EASY-E4 series)
Data Memory Typically ~2 KB (for EASY-E4 series)
Programming - EASY-SOFT PC Software
- Direct Device Programming via built-in display and keys
Programming Language Function Block Diagram (FBD) / Circuit Diagram style
Real-Time Clock (RTC) Yes
Communication - EASY-LINK (for networking multiple EASY controllers)
- USB Port for programming (on specific variants)
Display Backlit LCD for status, values, and diagnostics
Mounting Standard 35 mm DIN rail
Operating Temperature -25 °C to +55 °C (-13 °F to 131 °F)
Technical Parameters
Parameter Specification
Product Model EASY-E4-DC-12RC1
Product Family Eaton EASY-E4 Controller
Type Micro-PLC (Programmable Logic Controller)
Supply Voltage 24 V DC
Integrated I/O Total: 20 I/O Points
- 12x Digital Inputs (24 V DC, Sink/Source)
- 8x Relay Outputs:
• 6x Changeover Contacts (CO)
• 2x Normally Open Contacts (NO)
Relay Contact Rating - 6A @ 250V AC (for CO contacts)
- 2A @ 250V AC (for NO contacts)
Program Memory Typically ~4 KB (for EASY-E4 series)
Data Memory Typically ~2 KB (for EASY-E4 series)
Programming - EASY-SOFT PC Software
- Direct Device Programming via built-in display and keys
Programming Language Function Block Diagram (FBD) / Circuit Diagram style
Real-Time Clock (RTC) Yes
Communication - EASY-LINK (for networking multiple EASY controllers)
- USB Port for programming (on specific variants)
Display Backlit LCD for status, values, and diagnostics
Mounting Standard 35 mm DIN rail
Operating Temperature -25 °C to +55 °C (-13 °F to 131 °F)
Relative Humidity 95% (non-condensing)
Technical Parameters
Category Specification
Product Model EASY-E4-DC-12TC1
Product Family Eaton EASY-E4 Controller Series
Controller Type Micro PLC with Integrated Temperature Control
Power Supply 24V DC
Integrated I/O • 12x Digital Inputs (24V DC)
• 8x Relay Outputs (6x CO + 2x NO)
Relay Ratings • 6A @ 250V AC (CO contacts)
• 2A @ 250V AC (NO contacts)
Temperature Inputs 2 channels for thermocouple or RTD sensors
Temperature Ranges -200°C to 1800°C (depending on sensor type)
Control Algorithms • ON/OFF control
• PID control
• Heating/Cooling control
Program Memory 4 KB
Data Memory 2 KB
Real-Time Clock Integrated
Programming EASY-SOFT software or front panel
Programming Language Function Block Diagram (FBD)
Display Backlit LCD with status indicators
Communication EASY-LINK network capability
Mounting 35 mm DIN rail
Operating Temperature -25°C to +55°C
Protection Rating IP20 (for cabinet installation)
Technical Parameters
Parameter Specification
Product Model FY-EM-T02-02
Product Family Eaton F&F (Field & Function) Series
Device Type Programmable Energy & Power Monitoring Relay
Supply Voltage 24 - 240 V AC/DC (Wide Range, Auto-sensing)
Measurement Inputs Voltage: Up to 480 V AC (via potential transformer)
Current: 0-1A or 0-5A AC (via current transformer)
Measurement Channels 2 independent channels
Measured Parameters Voltage (V), Current (I), Active Power (kW), Apparent Power (kVA), Reactive Power (kvar), Power Factor (cos φ), Frequency (Hz), Energy (kWh, kvarh)
Outputs 2x Changeover Relay Contacts (CO)
- Rated Load: 6 A / 250 V AC
Communication Interface RS-485 with Modbus RTU protocol
Programming & Display - Front-face buttons and LCD display
- Configuration software (e.g., Eaton SOFISYS)
Primary Functions - Under/Over voltage & current monitoring
- Power & Power Factor monitoring
- Energy (kWh) metering & tariff control
- Asymmetry & Phase Sequence monitoring
- Timer & Threshold functions
Mounting Standard 35 mm DIN rail
Operating Temperature -25 °C to +55 °C (-13 °F to 131 °F)
Safety Standards IEC/EN 61010-1, UL 508
Technical Parameters
Parameter Specification
Product Model XIOC-8AI-12
Compatible Systems Eaton XP, XR, and XC Series PLCs
Module Type Analog Input Module
Number of Channels 8
Input Type Voltage
Input Range 0 to 10 V DC (Standard factory default; other ranges like ±10V may be configurable)
Resolution 12-bit (or higher, depending on the specific PLC system's processing capabilities)
Conversion Time Typically a few milliseconds per channel (varies based on the master PLC)
Connection Method Removable screw terminal block
Isolation Channel-to-Bus: Yes (Opto-coupled)
Channel-to-Channel: Typically not isolated
Power Supply Powered by the 5 V DC backplane of the PLC rack/base unit
Status Indicators - RUN/PWR: Green LED (indicates operational status)
- ERR: Red LED (indicates a fault)
- Ix: Status LED per channel (may be present)
Mounting Mounts onto the XP/XR/XC series base unit or rack
Operating Temperature 0 °C to +55 °C (32 °F to 131 °F)
Technical Parameters
Parameter Specification
Product Model XIOC-8DI
Compatible Systems Eaton XP, XR, and XC Series PLCs
Module Type Digital Input Module
Number of Channels 8
Input Type 24 V DC, Sink/Source (Universal)
Nominal Input Voltage 24 V DC
Rated Input Voltage "1" 15 V DC to 30 V DC
Rated Input Voltage "0" -30 V DC to 5 V DC
Input Current Typically 3-5 mA per input (at 24 V DC)
Connection Method Removable screw terminal block
Isolation Channel-to-Bus: Yes (Optically isolated)
Power Supply Powered by the 5 V DC backplane of the PLC rack/base unit
Status Indicators - RUN/PWR: Green LED (indicates operational status)
- ERR: Red LED (indicates a fault)
- INx: Green LED per channel (indicates input status)
Mounting Mounts onto the XP/XR/XC series base unit or rack
Operating Temperature 0 °C to +55 °C (32 °F to 131 °F)
Standards CE, cULus, RoHS