Key Parameters
Category Parameter Description / Typical Values
Input & Control Control Signal 4-20 mA DC.
Control Function Electronic setpoint for pressure reduction.
Pressure Ratings Maximum Inlet Pressure (P1) 400 psig (28 bar).
Outlet Pressure (P2) Range Determined by the internal pilot spring. Adjustable via the 4-20 mA signal across the spring's range.
Capacity Flow Coefficient (Cv) High Cv values, similar to other regulators in its size class (e.g., a 2" size has a Cv of ~65).
Size & Connections Pipe Size 3/4 inch to 4 inches.
End Connections Threaded (NPT) or Flanged.
Materials Body Material Cast Iron.
Internals Stainless Steel.
Electrical I/P Transducer Air Supply Requires a clean, dry instrument air supply (typically 20-100 psig).
Key Parameters
Category Parameter Description / Typical Values
Pressure Ratings Maximum Inlet Pressure (P1) 125 psig (8.6 bar).
Outlet Pressure (P2) Range Adjustable via spring selection. Common ranges span from 3.5" w.c. to 20 psig (approx. 0.87 kPa to 1.4 bar).
Capacity Flow Coefficient (Cv) Low to moderate Cv, suitable for its intended applications.
Size & Connections Pipe Size Typically 1/2 inch to 1-1/4 inch.
End Connections Threaded (NPT).
Materials Body Material Aluminum.
Internal Components Stainless Steel, Synthetic Rubber Diaphragm.
Safety Features Overpressure Protection (OPP) Integral Internal Relief Valve is a common optional feature.
Environment Operating Temperature Standard for gas service (e.g., -20°F to 150°F / -29°C to 66°C).
Key Parameters
Category Parameter Description / Typical Values
Compatibility Supported Protocols HART® (Highway Addressable Remote Transducer).
Compatible Instruments Fisher FIELDVUE Digital Valve Controllers and other HART communication devices.
Electrical Power Supply Loop-powered (draws power from the 4-20 mA loop of the connected HART instrument).
Loop Requirements Requires a minimum loop voltage and resistance to operate (e.g., typically > 11 VDC and < 1100 Ω).
Connectivity Computer Connection USB or Serial (RS-232) via appropriate cables.
Field Connection Standard test lead connectors.
Software Required Software Fisher FIELDVUE DVC Setup and Diagnostics Software or Emerson AMS Device Manager.
Environment Operating Temperature Standard for field use (e.g., 32°F to 140°F / 0°C to 60°C).
The Eaton NZM3-XR208-240AC is a high-performance molded case circuit breaker with electronic trip unit, designed for critical power distribution applications requiring advanced protection and monitoring capabilities.
The Eaton NZMN2-A250-NA UL is a UL-listed, 250A molded case circuit breaker designed for reliable circuit protection in commercial and industrial power distribution systems. This 2-pole MCCB combines robust construction with advanced thermal-magnetic trip technology.
The Eaton RGH65K 2000A 3P is a heavy-duty air circuit breaker designed for main power distribution in large industrial and commercial facilities. With a 2000A rating and 65kA interrupting capacity, this breaker provides reliable protection for critical high-current circuits.
The Eaton NSX 4P 80A is a premium 4-pole molded case circuit breaker from Eaton's NSX series, designed for advanced circuit protection in commercial and industrial applications requiring neutral pole protection.
The Eaton NSX 4P 80A is a premium 4-pole circuit breaker designed for critical power distribution systems requiring full neutral protection. Part of Eaton's award-winning NSX range, this MCCB combines advanced protection technology with smart monitoring capabilities.
The Eaton J250E is a heavy-duty molded case circuit breaker designed for industrial power distribution and equipment protection. This 250A frame breaker provides reliable overcurrent and short-circuit protection in demanding environments.
The Eaton T5-4-15682/I5/SVB is a precision multi-function time delay relay designed for industrial control applications. This versatile timing device offers programmable delay functions with robust construction for demanding environments.