Products
Products
home
Schneider
NSX250N3P250A
The Schneider Electric Masterpact NSX250N is a three-pole, 250A molded case circuit breaker (MCCB) from the premium Masterpact NSX range. The "N" suffix denotes its Standard breaking capacity.

More details >> Request a Quote >>
Schneider
WATSG250/4A 250A
The Schneider Electric Harmony WATSG250/4A is a watertight, 4-pole, 250A switch-disconnector from the heavy-duty WATSG range. Designed for the most demanding industrial and outdoor environments, it provides safe isolation, manual load switching, and emergency switching of high-current electrical circuits.

More details >> Request a Quote >>
Schneider
EZD160E 3P125A 160A
The Schneider Electric Acti 9 iEZ EZD160E is a three-pole electronic circuit breaker built on a 160A frame, with its electronic trip unit configured to provide protection for a 125A load. Equipped with a standard E-type electronic trip unit, it offers fully adjustable and precise protection against overloads and short-circuits.

More details >> Request a Quote >>
Schneider
WATSNA-63/4 63A
The Schneider Electric Acti 9 iEZ EZD250E is a three-pole electronic circuit breaker built on a 250A frame, with its electronic trip unit configured to provide protection for a 200A load. Equipped with a standard E-type electronic trip unit, it offers fully adjustable and precise protection against overloads and short-circuits.

More details >> Request a Quote >>
Schneider
EZD250E 3P200A 250A
The Schneider Electric Acti 9 iEZ EZD250E is a three-pole electronic circuit breaker built on a 250A frame, with its electronic trip unit configured to provide protection for a 200A load. Equipped with a standard E-type electronic trip unit, it offers fully adjustable and precise protection against overloads and short-circuits. This configuration is ideal for applications where the load current is 200A, but the robustness, higher breaking capacity, or future scalability of a 250A frame is desired or required

More details >> Request a Quote >>
Schneider
EZD250E,3P250A
The Schneider Electric Acti 9 iEZ EZD250E is a three-pole, 250A electronic circuit breaker from the advanced Acti 9 iEZ range. It is equipped with a standard E-type electronic trip unit, providing fully adjustable overload and short-circuit protection.

More details >> Request a Quote >>
FOXBORO
P0926JMA
Product Type Gauge Pressure Transmitter Measurement Principle Advanced sensor (e.g., Silicon Resonant) Output Signal 4-20 mA analog output with HART® Protocol Accuracy High, typically ±0.075% of span Pressure Range (URL) Example: 0-1600 kPa (based on code J) Process Connection Flush-mounted diaphragm (based on code M) Wetted Parts Material 316L Stainless Steel (based on code A) Power Supply 2-wire, 12-45 VDC (loop-powered) Operating Temperature -40°C to +85°C (ambient) Protection Rating NEMA 4X / IP67

More details >> Request a Quote >>
FOXBORO
875EC-J1F
Product Type Compact Magnetic Flowmeter (Integrated Transmitter and Tube) Measurement Principle Faraday's Law of Electromagnetic Induction Measured Media Electrically conductive liquids (typically with a conductivity > 5 μS/cm) Line Size 3-inch (DN80), based on code J Liner Material PTFE (Teflon®), based on code 1 Electrode Material 316L Stainless Steel, based on code F Accuracy Typical: ±0.5% of rate Output Signal 4-20 mA analog, pulse/frequency, typically with HART® Protocol Power Supply 100-240 VAC or 24 VDC (dependent on specific order code) Protection Rating Typically NEMA 4X / IP67 for field mounting

More details >> Request a Quote >>
FOXBORO
P0914LV
Model Number P0914LV Product Type Gauge Pressure Transmitter Pressure Type Gauge Pressure (pressure relative to atmospheric pressure) Sensor Technology Advanced high-stability sensor (e.g., silicon resonant or capacitive) Output Signal 4-20 mA analog output with HART® Protocol for digital communication. Accuracy High accuracy. For low-pressure "LV" models, this is often ±0.075% of the Upper Range Limit (URL) or calibrated span. Pressure Range (URL) The "LV" code is critical and typically indicates a low pressure range. The "14" in P0914LV often correlates to a specific range, such as 0-14 kPa (0-2 psi, 0-56 inches of water column). Process Connection Low-pressure ports, often 1/4" NPT or similar, suitable for low-pressure gases. Wetted Parts Material 316L Stainless Steel is standard. Power Supply Standard 2-wire, 12-45 VDC loop-powered operation. Operating Temperature Ambient: -40°C to +85°C (-40°F to 185°F). Process: Dependent on seal options. Protection Rating NEMA 4X / IP67 (weatherproof and corrosion-resistant).

More details >> Request a Quote >>
FOXBORO
IPM2-P0904HA REV.A
Product Type Rack-mounted Intelligent Pressure Module Integrated System Foxboro I/A Series DCS Measurement Type Differential Pressure (DP) Typical Range (URL) Example: 0-400 inH₂O (approx. 0-100 kPa) - specific to the H code. Accuracy Very high, typically better than ±0.1% of span. Output Signal Digital communication directly to the I/A Series controller via the system's backplane or proprietary bus. Power Supply Powered via the I/A Series rack backplane. Process Connection External wiring terminals for connecting wires from the field (e.g., from a remote seal or impulse lines). Operating Temperature Designed for a controlled cabinet environment. Primary Application Flow Measurement (with primary elements like orifice plates) and Level Measurement.

More details >> Request a Quote >>
1 2
··· ···