DG4V-3-8C-VM-U-H7-61
Key Parameters
Item Parameter / Description
Actuation Type Solenoid operated (single-stage)
Coil Voltage 24 V DC (standard)
Valve Size / Interface ISO 4401‑03 / NFPA D03 / CETOP 3 (NG6)
Maximum Operating Pressure (P, A, B ports) 350 bar (≈ 5075 psi)
Tank Port (T) Pressure Rating 210 bar (≈ 3045 psi)
Maximum Flow Rate Up to 80 L/min (≈ 21 US gpm)
Seal Material Viton (standard)
Spool Type Spool “8C”
Spring Arrangement Spring-offset spool
Fluid Compatibility Petroleum-based hydraulic oils
Fluid Cleanliness (Filtration) Recommendation 19/17/14 (micron)
Operating Temperature Range –20 °C to +70 °C (–4 °F to +158 °F)
Mounting Type Subplate / manifold mounted
Power Consumption (Coil) 30 W