Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Series IZM97
Product Model IZM97B3-U20W
Product Type Fixed Mounted Air Circuit Breaker (ACB)
Number of Poles 3 Poles
Rated Insulation Voltage (Ui) 1000 V AC
Rated Operational Voltage (Ue) 690 V AC
Frame Size (Inm) 3200 A
Rated Current (Iu) 3200 A (Adjustable via trip unit)
Rated Ultimate Breaking Capacity (Icu) at 415V 150 kA (IEC 60947-2)
Trip Unit U20W (Advanced Electronic Trip Unit)
Protection Functions Long-time, Short-time, Instantaneous, Ground Fault, Load Monitoring
Measurement & Monitoring Current, Voltage, Power, Energy, Power Factor, Frequency, Harmonics (THD)
Communication Protocols Embedded Ethernet (Modbus TCP), RS-485 (Modbus RTU)
Display Graphical LCD Display
Mounting Fixed Installation in Switchboard
Standards IEC 60947-2
Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Designation IZM-DTP+EPA (Combination Kit)
Compatible Series Eaton IZM Series Air Circuit Breakers
Components Included 1 x Digital Test Plug (IZM-DTP)
1 x Extended Protection Adapter (IZM-EPA)
Digital Test Plug (DTP) Function Secondary Injection Testing of the Electronic Trip Unit
Extended Protection Adapter (EPA) Function Provides connection points for external Earth Fault (Ground Fault) protection sensors.
Typical Use Case • Testing & Commissioning: Verify trip unit settings and functionality.
• Enhanced Protection: Implement comprehensive ground fault protection by connecting external CBCTs (Core Balance Current Transformers).
Connection Plugs directly into the electronic trip unit of compatible IZM breakers.
Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Series IZM97
Product Model IZM97N3-V25F
Product Type Fixed Mounted Air Circuit Breaker (ACB)
Number of Poles 3 Poles
Rated Insulation Voltage (Ui) 1000 V AC
Rated Operational Voltage (Ue) 690 V AC
Frame Size (Inm) 2500 A
Rated Current (Iu) 2500 A (adjustable via trip unit)
Rated Ultimate Breaking Capacity (Icu) at 415V 100 kA (IEC 60947-2)
Trip Unit V25F (Electronic Trip Unit)
Protection Functions Long-time, Short-time, Instantaneous, Ground Fault
Measurement Functions Current, Voltage (with external VT), Power, Energy, etc.
Communication Supports communication modules (optional)
Display LCD Display
Mounting Fixed Installation in Switchboard
Standards IEC 60947-2
Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Series IZMX
Product Model IZMX16H3-V12W
Product Type Molded Case Circuit Breaker (MCCB)
Number of Poles 3 Poles
Rated Operational Voltage (Ue) 400 V AC (50/60 Hz)
Frame Size (Iu) 160 A
Rated Current (In) Adjustable, up to 160 A
Rated Ultimate Breaking Capacity (Icu) at 415V 36 kA (IEC 60947-2)
Trip Unit Type V12W Electronic Trip Unit
Protection Functions Long-time delay (L), Short-time delay (S), Instantaneous (I), Ground-fault (G)
Measurement Functions Current, Voltage, Power, Energy, Power Factor, Frequency
Communication Supports optional communication modules (e.g., for Modbus)
Display LCD display for parameter setting and measurement reading
Mounting Fixed Installation
Standards IEC 60947-2
Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Series IZMX
Product Model IZMX40-2500A
Product Type Molded Case Circuit Breaker (MCCB)
Number of Poles 3 Poles
Rated Operational Voltage (Ue) 690 V AC
Frame Size (Iu) 2500 A
Rated Current (In) 2500 A
Rated Ultimate Breaking Capacity (Icu) at 415V 150 kA (IEC 60947-2)
Trip Unit Type Fixed Magnetic (Non-adjustable)
Protection Functions Overload (via thermal bi-metallic strip), Instantaneous Short-Circuit (Magnetic)
Operating Mechanism Manual (Standard)
Mounting Fixed Installation in Switchboard
Standards IEC 60947-2
Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Series IZM97
Product Model IZM97B3-P40W
Product Type Fixed Mounted Air Circuit Breaker (ACB)
Number of Poles 3 Poles
Rated Insulation Voltage (Ui) 1000 V AC
Rated Operational Voltage (Ue) 690 V AC
Frame Size (Inm) 3200 A
Rated Current (Iu) 4000 A
Rated Ultimate Breaking Capacity (Icu) at 415V 150 kA (IEC 60947-2)
Trip Unit P40W (Advanced Electronic Trip Unit)
Protection Functions Long-time, Short-time, Instantaneous, Ground Fault, Load Monitoring
Measurement Functions Current, Voltage, Power, Energy, Frequency, Power Factor, Harmonics, etc.
Communication Protocols Embedded Ethernet (Modbus TCP), RS-485 (Modbus RTU)
Display Graphical LCD Display
Mounting Fixed Installation in Switchboard
Standards IEC 60947-2
Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Series IZM91
Product Model IZM91N3C-V16F
Product Type Draw-Out Air Circuit Breaker (ACB)
Number of Poles 3 Poles
Rated Operational Voltage (Ue) 690 V AC
Frame Size (Inm) 1600 A
Rated Current (Iu) 1600 A (Adjustable via trip unit)
Rated Ultimate Breaking Capacity (Icu) at 415V 65 kA (IEC 60947-2)
Trip Unit V16F (Electronic Trip Unit)
Protection Functions Long-time, Short-time, Instantaneous, Ground Fault
Measurement Functions Current, Voltage, Power, Energy, Power Factor, Frequency
Communication Supports communication modules (optional)
Mounting Style Draw-Out (in compatible fixed mounting frame)
Display LCD Display
Standards IEC 60947-2
Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Series IZMX
Product Model IZMX16N3-V12W
Product Type Molded Case Circuit Breaker (MCCB) with Electronic Trip Unit
Number of Poles 3 Poles
Rated Operational Voltage (Ue) 400 V AC (50/60 Hz)
Frame Size (Iu) 160 A
Rated Current (In) Adjustable, up to 160 A
Rated Ultimate Breaking Capacity (Icu) at 415V 36 kA (IEC 60947-2)
Trip Unit Type V12W Electronic Trip Unit
Protection Functions Long-time delay (L), Short-time delay (S), Instantaneous (I), Ground-fault (G)
Measurement Functions Current, Voltage, Power, Energy, Power Factor, Frequency
Communication Supports optional communication modules (e.g., for Modbus)
Display LCD display for parameter setting and measurement reading
Mounting Fixed Installation
Standards IEC 60947-2
Technical Parameters Parameter Category Specification / Value
Brand Eaton
Product Series IZMX
Product Model IZMX16H44-V16W
Product Type 4-Pole Molded Case Circuit Breaker (MCCB) with Electronic Trip Unit
Number of Poles 4 Poles (3 Poles + Neutral)
Rated Operational Voltage (Ue) 400 V AC (50/60 Hz)
Frame Size (Iu) 160 A
Rated Current (In) Adjustable, up to 160 A
Rated Ultimate Breaking Capacity (Icu) at 400V 36 kA (IEC 60947-2, typical value for this frame)
Trip Unit Type V16W Electronic Trip Unit
Protection Functions Long-time delay (L), Short-time delay (S), Instantaneous (I), Ground-fault (G)
Measurement Functions Current, Voltage, Power, Energy, Power Factor, Frequency, Harmonics
Communication Supports optional communication modules (e.g., for Modbus)
Display LCD display for parameter setting and measurement reading
Mounting Fixed Installation
Standards IEC 60947-2
Technical Parameters
Parameter Category Specification / Value
Brand Eaton
Product Series IZM91
Product Model IZM91N3-U06W
Product Type Draw-Out Air Circuit Breaker (ACB)
Number of Poles 3 Poles
Rated Operational Voltage (Ue) 690 V AC
Frame Size (Inm) 630 A
Rated Current (Iu) 630 A (Adjustable via trip unit)
Rated Ultimate Breaking Capacity (Icu) at 415V 65 kA (IEC 60947-2)
Trip Unit U06W (Advanced Electronic Trip Unit)
Protection Functions Long-time, Short-time, Instantaneous, Ground Fault
Measurement & Monitoring Current, Voltage, Power, Energy, Power Factor, Frequency, Harmonics (THD)
Communication Protocols Embedded Ethernet (Modbus TCP), RS-485 (Modbus RTU)
Mounting Style Draw-Out (in compatible fixed mounting frame)
Display Graphical LCD Display
Standards IEC 60947-2