Technical Parameters
Parameter Specification
Product Model XIOC-8AI-12
Compatible Systems Eaton XP, XR, and XC Series PLCs
Module Type Analog Input Module
Number of Channels 8
Input Type Voltage
Input Range 0 to 10 V DC (Standard factory default; other ranges like ±10V may be configurable)
Resolution 12-bit (or higher, depending on the specific PLC system's processing capabilities)
Conversion Time Typically a few milliseconds per channel (varies based on the master PLC)
Connection Method Removable screw terminal block
Isolation Channel-to-Bus: Yes (Opto-coupled)
Channel-to-Channel: Typically not isolated
Power Supply Powered by the 5 V DC backplane of the PLC rack/base unit
Status Indicators - RUN/PWR: Green LED (indicates operational status)
- ERR: Red LED (indicates a fault)
- Ix: Status LED per channel (may be present)
Mounting Mounts onto the XP/XR/XC series base unit or rack
Operating Temperature 0 °C to +55 °C (32 °F to 131 °F)
Technical Parameters
Parameter Specification
Product Model XIOC-8DI
Compatible Systems Eaton XP, XR, and XC Series PLCs
Module Type Digital Input Module
Number of Channels 8
Input Type 24 V DC, Sink/Source (Universal)
Nominal Input Voltage 24 V DC
Rated Input Voltage "1" 15 V DC to 30 V DC
Rated Input Voltage "0" -30 V DC to 5 V DC
Input Current Typically 3-5 mA per input (at 24 V DC)
Connection Method Removable screw terminal block
Isolation Channel-to-Bus: Yes (Optically isolated)
Power Supply Powered by the 5 V DC backplane of the PLC rack/base unit
Status Indicators - RUN/PWR: Green LED (indicates operational status)
- ERR: Red LED (indicates a fault)
- INx: Green LED per channel (indicates input status)
Mounting Mounts onto the XP/XR/XC series base unit or rack
Operating Temperature 0 °C to +55 °C (32 °F to 131 °F)
Standards CE, cULus, RoHS
Technical Parameters
Category Specification
Product Model ERC3-DO-CB-A-V100BI
Product Family Eaton ERC3 System
Module Type Digital Output Communication Board
Output Configuration 4 independent channels
Output Type Relay contacts (Changeover)
Contact Rating 16A @ 250V AC
Load Type Resistive, inductive, lamp loads
Control Voltage 230V AC (via main unit)
- Communication KNX TP1 (Twisted Pair)
Protocol KNX Standard
Programming ETS (KNX Engineering Tool Software)
Configuration Application program "A"
Mounting DIN rail (within ERC3 enclosure)
Operating Temperature -5°C to +45°C
Storage Temperature -25°C to +70°C
Relative Humidity ≤ 93% (non-condensing)
Protection Class IP20 (when installed in enclosure)
Standards Compliance KNX Standard, EN 50090, EN 60669-1
Electrical Characteristics
Rated Impulse Voltage: 4kV
Dielectric Strength: 2.5kV AC (50Hz)
Insulation Resistance: >100MΩ
Power Consumption: <1W (standby), <2W (active)
Communication Features
KNX Address: Individual and group addressing
Telegram Rate: Up to 9600 bps
Bus Connection: KNX red/grey terminal
Configuration: Via ETS software
Application Functions
Lighting control (on/off, dimming)
Blind/shutter control
Heating control
Ventilation control
Signal functions
Technical Parameters
Parameter Specification
Product Model NZM1-XA110-130AC/DC
Product Family Eaton NZM1 Circuit Breaker Accessory
Device Type Under-Voltage Release / Shunt Trip Release
Rated Operational Voltage (Ue) 110 - 130 V AC/DC (Wide Range)
Power Consumption Approx. 10 W / 20 VA (at moment of tripping)
Mounting Position Can be mounted on either the left or right side of the NZM1 breaker
Compatibility Designed for Eaton NZM1 Molded Case Circuit Breakers
Function Remotely trips the circuit breaker when the control voltage is applied.
Electrical Life Typically > 1000 operations (at rated voltage)
Connection Via screw terminals on the accessory
Standards IEC/EN 60947-2
Technical Parameters
Parameter Specification
Product Model MATSG-630/3
Product Family Eaton MATSG Automatic Transfer Switches
Type 3-Pole Automatic Transfer Switch
Rated Operational Current (Ie) 630 A
Rated Insulation Voltage (Ui) 690 V AC
Rated Operational Voltage (Ue) 400 V AC / 50 Hz
Short-Circuit Withstand Typically 50 kA (Icw) according to IEC 60947-6-1
Utilization Category AC-33A (for motors or mixed loads)
Mechanical Life Several thousand operations
Electrical Life Typically 1000+ operations at rated current
Control Voltage Standard options: 24 V DC, 110 V AC, 220 V AC
Status Indication Source 1 ON, Source 2 ON, Intermediate (OFF) Position
Standards & Certifications IEC/EN 60947-6-1, CE Marked
Technical Parameters
Category Specification
Product Model MATSG-200/4
Product Family Eaton MATSG Automatic Transfer Switch Series
Rated Current 200A
Number of Poles 4
Rated Operational Voltage 400V AC
Rated Insulation Voltage 690V AC
Rated Frequency 50/60 Hz
Short-Time Withstand Current 10kA (1 second)
Utilization Category AC-33A
Mechanical Life 10,000 operations
Electrical Life 1,000 operations at rated current
Control Voltage 24V DC / 230V AC (depending on configuration)
Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Relative Humidity 95% (non-condensing)
Protection Degree IP20 (for enclosure mounting)
Standards Compliance IEC 60947-6-1, CE
Technical Parameters
Category Specification
Product Model MATSG-63/4
Product Family Eaton MATSG Automatic Transfer Switch Series
Rated Current 63A
Number of Poles 4
Rated Operational Voltage 400V AC
Rated Insulation Voltage 690V AC
Rated Frequency 50/60 Hz
Short-Time Withstand Current 6kA (1 second)
Utilization Category AC-33A
Mechanical Life 10,000 operations
Electrical Life 1,000 operations at rated current
Control Voltage 24V DC / 230V AC (depending on configuration)
Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Relative Humidity 95% (non-condensing)
Protection Degree IP20 (for enclosure mounting)
Standards Compliance IEC 60947-6-1, CE
Technical Parameters
Category Specification
Product Model MATS G-250/4
Product Family Eaton MATS G Automatic Transfer Switch Series
Rated Current 250A
Number of Poles 4
Rated Operational Voltage 400V AC
Rated Insulation Voltage 690V AC
Rated Frequency 50/60 Hz
Short-Time Withstand Current 15kA (1 second)
Utilization Category AC-33A
Mechanical Life 8,000 operations
Electrical Life 800 operations at rated current
Control Voltage 24V DC/230V AC (configurable)
Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Relative Humidity 95% (non-condensing)
Protection Degree IP20 (requires enclosure)
Standards Compliance IEC 60947-6-1, CE
Technical Parameters
Category Specification
Product Model 5PX2200IRT3UG2
Product Family Eaton 5PX Series UPS
Topology Double Conversion Online
Rated Capacity 2200VA/1980W
Input Characteristics
- Voltage Range 200-240V AC
- Frequency Range 50/60 Hz (auto-sensing)
- Power Factor >0.99
- Input Connection IEC 320 C14
Output Characteristics
- Voltage 200-240V AC
- Frequency 50/60 Hz (±0.5% synchronous)
- Waveform Pure Sine Wave
- Efficiency Up to 96% (in online mode)
- Output Connections (8) IEC 320 C13
Battery System
- Battery Type Sealed Lead-Acid (SLA)
- Typical Runtime 5.5 min at full load (with internal batteries)
- Recharge Time 3 hours to 90% capacity
- Battery Life 3-5 years (typical)
Physical Specifications
- Form Factor 2U Rack-mountable
- Dimensions 88 × 482 × 660 mm (H×W×D)
- Weight 24.5 kg
Environmental
- Operating Temperature 0°C to 40°C
- Operating Humidity 0-95% non-condensing
- Audible Noise <45 dBA at 1 meter
Communications
- Interfaces USB, Serial, Network slot
- Management Eaton Intelligent Power Manager
- Display Color LCD graphical display